Barber-Colman DYNA 8000 Technical Manual

Manual is about: ELECTRONIC GOVERNOR

Summary of DYNA 8000

  • Page 1

    Technical manual for dyna 8000, 8200 & 8400 electronic governor dyna 8000 dyna 8200 dyna 8000-400 & dyna 8400-400 dyna 8400 f-23721-5.

  • Page 2: Contents

    Contents section description page 1 general information ........................... 3 2 specifications......................................... 3 3 functional description ..................... 5 4 installation ............................................. 6 5 calibration of dyn1-1065x .................

  • Page 3

    = input signal frequency in hertz 3 2.1.10 dyna 8000 controller nominal quiescent current 80 ma maximum amperes @ stall 13 amps nominal quiescent current 80 ma maximum amperes @ stall 13 amps kilograms 0.863 pounds 1.9 output current @ 24 vdc weight output current @ 12 vdc 2.1.11 dyna 8000 controlle...

  • Page 4

    2.2.11 available dyna 8000 hazardous duty actuator models with clockwise output shaft rotation (standard mounted units) • dync-11020-400-0-12 standard clockwise dync-11020-400-0-24 output shaft rotation • dync-11021-400-0-12 actuator head positioned 180 ° dync-11021-400-0-24 from standard dync-11020...

  • Page 5

    Current @ 24 vdc current@ 12 vdc weight output torque work nominal response time for 63% of stroke (seconds) .138 work torque output weight current @ 24 vdc nominal response time for 63% of stroke (seconds) 0.104 2.3.6 available dyna 8200 actuator models with clockwise output shaft rotation • dync-1...

  • Page 6

    Full load engine rpm no load engine rpm adjustable 100% % of engine load 0% engine rpm note mounting information and kits are usually available for a particular engine. Contact sales representative. 4.1.2 set up the linkage and rod end bearings (see 4.2). 4.1.3 install the speed sensor with sae thre...

  • Page 7

    4.2.1 rotary actuator to rotary fuel pump 4.2 typical linkage arrangements for the actuator and fuel system 4.2.2 rotary actuator to linear fuel pump installation of magnetic pickup 4.1.4 mount the controller in the control panel. 4.1.5 connect the wiring as shown in section 4.3 or according to your...

  • Page 8

    † the 5k remote speed potentiometer can be wired two different ways: 1. As shown by the solid line from the wiper of the 5k potentiometer and then connected to terminal #9 (no resistor required). Adjust- able range is approximately ± 5% at 1800 rpm. 2. As shown by the dashed line from the wiper of t...

  • Page 9

    2500 to 5000 hz 5000 to 9000 hz dyn1-10652-000-0-12/24 dyn1-10652-001-0-12/24* dyn1-10653-000-0-12/24 dyn1-10653-001-0-12/24* ] ] 250 to 1200 hz 1200 to 2500 hz part number dyn1-10654-000-0-12/24 dyn1-10654-001-0-12/24* dyn1-10656-000-0-12/24 dyn1-10656-001-0-12/24* ] ] part number input signal freq...

  • Page 10

    Side view "on" on off side view "off" off on o n o f f top view s1 s2 5.5 proper procedures for setting switches s1 and s2 question: how do i know if the switches in the dual-in-line packages are correctly set as far as being in the off position or the on position? Answer: the drawings above should ...

  • Page 11

    6. Calibration procedure for 8000 governor controller — dyn1-10682, 10683, 10684, 10686 dyn1-10682-000-0-12/24 dyn1-10682-001-0-12/24* dyn1-10683-000-0-12/24 dyn1-10683-001-0-12/24* input signal frequency maximum input signal frequency maximum part number part number dyn1-10684-000-0-12/24 dyn1-1068...

  • Page 12

    Side view "on" on off side view "off" off on o n o f f top view s1 s2 12 6.5 general information on s1 and s2 • switch s1 selects one of two integrating rate ranges. The diesel version integrates at twice the rate of the gas version. • switch s2 selects the point at which actuator coil current level...

  • Page 13

    7. Dyna 8000 series troubleshooting chart 7.1 problem: governor is completely dead and actuator lever stays at minimum position when power is applied to governor. Check battery connections and contacts for turning power on to the controller. Correct and free linkage. Check pole tip gap over gear too...

  • Page 14

    Means of detection corrective action verify and correct wiring as necessary. Verify and correct wiring as necessary. Replace controller. If continuity is detected, replace the controller. Turn dc power on to the governor if the actuator is now normal. Proceed to step 7.3.1. Means of detection check ...

  • Page 15

    7.5 problem: slow, small amplitude hunting of speed or frequency means of detection 7.5.1 sticking or very loose linkage. Corrective action correct linkage. Means of detection 7.6.1 verify calibration settings of the controller. Corrective action readjust settings as necessary. 7.6 problem: fast osc...

  • Page 16

    16 dync-11024-000 actuator — counterclockwise rotation dync-11024-300 side mounted actuator — counterclockwise rotation dync-12000-000

  • Page 17

    Dync-14800-000 terminal strip connection dync-14801-000 2-pin ms connector connection 17 dync-11020-401 ul approval, hazardous duty, class 1, division 2, group d clockwise unit.

  • Page 18

    Dync-11024-400 ul approval, hazardous duty, class 1, division 2, group d counterclockwise unit dync-14800-400 ul approval, hazardous duty, class 1, division 2, group d f-23721-5 an invensys company barber-colman dyna products 1354 clifford avenue (zip 61111) telephone (815) 637-3000 p.O. Box 2940 fa...