Barco DATA 708 Installation Manual

Other manuals for DATA 708: Owner's Manual, Installation Manual
Manual is about: Barco projector OWNER'S MANUAL

Summary of DATA 708

  • Page 1

    R9002129 installation manual data 708.

  • Page 3: Barco Projection Systems

    Barco projection systems date : 260597 art. No. : r5975987a r9002129 installation manual data 708.

  • Page 4

    Due to constant research, the information in this manual is subject to change without notice. Produced by barco nv, may 1997. All rights reserved. Trademarks are the rights of their respective owners. Barco nv/projection systems noordlaan 5 b-8520 kuurne belgium printed in belgium.

  • Page 5: Table of Contents

    Table of contents i - 1 5975987a barcodata 708 260597 table of contents i warnings .................................................................................................................................................................................... 1-1 safety instructions ...............

  • Page 6

    Table of contents i - 2 5975987a barcodata 708 260597.

  • Page 7: Safety Instructions

    Safety instructions 1-1 5975987a barcodata 708 260597 warning to prevent fire or electrical shock hazard, do not expose this equipment to rain or moisture federal communication commission (fcc statement) this equipment has been tested and found to comply with the limits of a class a digital device, ...

  • Page 8

    Safety instructions 1-2 5975987a barcodata 708 260597 power cord with ansi 73.11 plug: the wires of the power cord are colored in accordance with the following code. Green/yellow: ground white: neutral black: line (live) 3. Do not allow anything to rest on the power cord. Do not locate this product ...

  • Page 9: Unpacking And Dimensions

    Unpacking and dimensions 2 - 1 5975987a barcodata 708 260597 2 unpacking and dimensions unpacking take the projector out of its shipping carton and place it on a table. Save the original shipping carton and packing material, they will come in handy if you ever have to ship your projector. For maximu...

  • Page 10

    Unpacking and dimensions 2 - 2 5975987a barcodata 708 260597 projector dimensions (mm).

  • Page 11: Installation Guidelines

    Installation guidelines 3-1 5975987a barcodata 708 260597 3 installation guidelines installation guidelines careful consideration of things such as image size, ambient light level, projector placement and type of screen to use are critical to the optimum use of the projection system. * environment d...

  • Page 12

    Installation guidelines 3-2 5975987a barcodata 708 260597 * where to install the projector? To indicate a correct installation position it is necessary to know the distance : - projector - ceiling - projector - screen to find this correct position for the projector, equipped with hd145 lenses, formu...

  • Page 13: Installation Set Up

    Installation set up 1-1 5975987a barcodata 708 260597 4 installation set up access to controls opening procedure : during the projector set up and installation it is neces- sary to open the top cover. To gain access, procede as follow : *turn both lock screws with a screwdriver or a coin counter clo...

  • Page 14

    Installation set up 4-2 5975987a barcodata 708 260597 scan adaptation the scanning can be switch by turning the horizontal and vertical scan connectors and the convergence connectors. To change the scanning, it is necessary to open the projector top cover and to rotate the chassis. For opening the p...

  • Page 15

    Installation set up 1-3 5975987a barcodata 708 260597 a : horizontal scan inversion three connectors are used, one for each horizontal deflection coil. When changing the horizontal scan, insure that all three connectors are set in the same position. See position of the connectors for the correspondi...

  • Page 16

    Installation set up 4-4 5975987a barcodata 708 260597.

  • Page 17: Projector Set Up

    Projector set up 5-1 5975987a barcodata 708 260597 5 projector set up projector set up the strap on the cpu unit allow a set up of the password mode. Gaining access to the strap - open the top cover (see installation set up) - open the chassis (see installation set up) horizontal scan connectors ver...

  • Page 18

    Projector set up 5-2 5975987a barcodata 708 260597.

  • Page 19: Power Connection

    Power connection 6-1 5975987a barcodata 708 260597 6 power connection power (mains) cord connection use the supplied power cord to connect your projector to the wall outlet. Plug the female power connector into the male connector at the front of the projector. See installation instructions before co...

  • Page 20

    Power connection 6-2 5975987a barcodata 708 260597.

  • Page 21: Installation Adjustments

    Installation adjustments 7 - 1 5975987a barcodata 708 260597 7 installation adjustments entering the adjustment mode adjustment mode select a path from below: select with or then to return guided random access installation service iris source 1 random access adjustment guided adjustment installation...

  • Page 22

    Installation adjustments 7 - 2 5975987a barcodata 708 260597 overview flow chart installation mode. Scheimpflug adjustment to continue to return loosen the 4 lens mounting nuts on each lens, until the tag of each scheimpflug ring can be moved to its desired position (1.4 m, 2.4 m or 4.0 m screen wid...

  • Page 23

    Installation adjustments 7 - 3 5975987a barcodata 708 260597 adjustment mode select a path from below: select with or then to return guided random access installation service iris source 1 push the control disk up or down to highlight "installation" and press enter. Enter continues displaying a warn...

  • Page 24

    Installation adjustments 7 - 4 5975987a barcodata 708 260597 scheimpfug adjustment the scheimpfug correction can be adjusted separately for the three tubes within 3 ranges: range 1 : 1.4 m (55") to 1.9 m (75"), optimum screen width 1.4 m (55") range 2 : 1.9 m (75") to 3.2 m (126"), optimum screen wi...

  • Page 25

    Installation adjustments 7 - 5 5975987a barcodata 708 260597 optical lens focusing optical lens focusing to continue to return 1. Loosen the nut on the rear of the xxxx lens, rotate the lens barrel to focus the center of the image, then tighten the nut 2. Loosen the nut on the front of the xxxx lens...

  • Page 26

    Installation adjustments 7 - 6 5975987a barcodata 708 260597 raster centering the raster must be centered on the crt screen surface of each tube, therefore, it is necessary to look into the lenses. Caution : to avoid eye discomfort while performing these adjust- ments, reduce the contrast and gradua...

  • Page 27

    Installation adjustments 7 - 7 5975987a barcodata 708 260597 crt projection angle adjustment the projection angle of the red and blue crt's is dependent on the desired size of the projected image. If the centers of green, blue and red do not coincide, the crt projection angle must be adjusted. Never...

  • Page 28

    Installation adjustments 7 - 8 5975987a barcodata 708 260597 loosen the four hexagon screws a, a', b and b', upper and lower fixation latch. These screws fasten the cooling house of the red tube. Pivot the red crt until the center of the red image coincides with the center of the green image. If the...

  • Page 29

    Installation adjustments 7 - 9 5975987a barcodata 708 260597 adjustment mode source 1 select with or then to return guided random access installation service iris after finishing the installation adjustments procedure, the 'path selection' returns on the screen. You are now able to start the alignme...

  • Page 30

    Installation adjustments 7-10 5975987a barcodata 708 260597.

  • Page 31: G2 Adjustment

    G2 adjustment a-1 5975987a barcodata 708 260597 a g2 adjustment enter the adjustment mode by pressing adjust and highlight service. Press enter to start up the service mode. G2 adjustment adjustment mode select a path from below: select with or then to return source 1 guided random access installati...

  • Page 32

    G2 adjustment a-2 5975987a barcodata 708 260597 a green led for each color is mounted on the driver board, below the crt's. When selecting the g2 adjustment menu, these green leds must be out. If not, follow the procedure to adjust the g2 : - loosen the retaining screws of the upper electronic chass...

  • Page 33: 1813

    Formula outside package dimensions (inches) chemical family federal stock number (fsn) gross weight (lbs) % treshold limit value (units) alloys and metallic coatings % % pigments solvents additives catalyst vehicle hazardous mixtures of other liquids, solids, or gases appearance and odor boiling poi...

  • Page 34

    Stability unstable stable conditions to avoid incompatability (materials to avoid) hazardous decomposition products hazardous polymerization will not occur conditions to avoid may occur steps to be taken in case material is released or spilled waste disposal method respiratory protection (specific t...