Bartscher QUASAR 130 C Technical & Service Manual

Manual is about: Ice Cube Maker

Summary of QUASAR 130 C

  • Page 1

    1 quasar (r404a) technical service manual ice cube makers models: quasar 20 c quasar 30 c quasar 40 c quasar 40s c quasar 50 c quasar 60 c quasar 90 c quasar 130 c quasar 150 c modulars: mq 200 carefully read the instructions contained in this manual since they provide important information relative...

  • Page 2

    2 table of contents introduction warnings.....................................................................................................................................................3 description ...................................................................................................

  • Page 3

    3 introduction thank you for choosing quasar-c ice cube makers. You have purchased one of the most reliable ice-making products on the market today. Carefully read the instructions contained in this manual since they provide important information relative to safety during installation, use, and main...

  • Page 4

    4 description the quasar-c ice cubes maker is the result of years of experience in this field and the development of a high technology factory. Main features • storage bin made of polyester strengthened with glass fibre or abs • stock bin made of high resistance plastic materials • polyurethane insu...

  • Page 5

    5 once the storage bin is full the pan stops in its downward movement as it touches the cubes, so working the safety stop micro-switch and switching off the machine. Production will start again as soon as the cubes which detained it move or are removed..

  • Page 6

    6.

  • Page 7

    7 specificacions models: quasar 20/30/40/40s/50/60/90/130/150 * height z represents minimum machine height. If legs are placed under machine, then add an extra 80 mm.* model x y z a b c d e f g quasar 20 c 405 510 690 60 35 65 123 45 65 105 quasar 30 c 405 510 745 60 35 65 123 45 65 105 quasar 40 c ...

  • Page 8

    8 stock thermostat water inlet electrical connection.

  • Page 9

    9 technical data model cooling water usage l/hour (1) ice production water usage l/hour (1) total water usage l/hour (1) net weight (kg) dimensions crated x*y*z gross weight (kg) volume (m 3 ) quasar 20c a 4 4 36 490x595x765 41 0.22 quasar 20c w 15 4 19 36 490x595x765 41 0.22 quasar 30c a 4 4 39 490...

  • Page 10

    10 production tables for ice cube makers (kg/day) quasar 20 c quasar 30 c 45 25 22 27 20 28 19.5 29 19 30 18 30.5 17 32 16 25 26 27 24 28 23 29 22 30 21 30.5 20 32 19 40 24 24 25 22 27 20 28 19.5 29 19 30 18 31 17 24 28 25 26 27 24 28 23 29 22 30 21 31 20 35 22 25 24 24 25 22 27 20 28 19.5 29 19 30 ...

  • Page 11

    11 quasar 90 c quasar 130 c 45 24 71 26 66 28 61 29 59 30 57 31 55 32 53 24 99 26 92 28 85 29 81 30 79 31 77 32 74 40 23 74 24 71 26 66 28 61 29 59 30 57 31 55 23 103 24 99 26 92 28 85 29 81 30 79 31 77 35 22 77 23 74 24 71 26 66 28 61 29 59 30 57 22 108 23 103 24 99 26 92 28 85 29 81 30 79 30 21 83...

  • Page 12

    12 delivery & unpacking upon receipt, thoroughly inspect the packing container. If there appears to be damage to the container contact the shipper immediately. Unpack unit in the presence of delivery personnel noting any damage on the waybill. Packing bears the “green point” on all mode ording to th...

  • Page 13

    13 installation the ice cube maker is delivered on a small wooden pallet and is protected with a cardboard box and packaging. Loosen the cardboard box by cutting the straps, then lift vertically. After having removed the packaging, make sure the machine is complete. If in doubt do not use it and go ...

  • Page 14

    14 access to condenser and/or water pressure valve, allow sufficient space at front of the machine. Be sure that flooring is firm and even. Water and drainage water quality influences ice hardness, flavour, and quality as well as condenser life. Keep in mind the following points: a) water impurities...

  • Page 15

    15 connecting unit to drain (water cooled models) •drain must be located at least 150mm. Below machine level. Drain tube must have an inner diameter of 30mm. With a minimum gradient of 3 cm per metre. Electrical connection • unit is provided with a 1.5 m cord and schucko socket. • it is recommended ...

  • Page 16

    16 important! Supply socket must be properly earthed. Be sure to check standard for country where appliance is going to be installed. Operation preliminary check a) is machine levelled? B) are voltage and frequency of main supply the same as indicated on rating plate? C) is drainage system functioni...

  • Page 17

    17 important! Be sure voltage and frequency of main supply correspond to indicated levels on rating plate. Advise the final user on maintenance procedures which are not included in warranty, as well as those breakdowns caused by neglect of proper maintenance procedures. Adjustments condenser water v...

  • Page 18

    18 pressure control fan pressostat (air condensation) pressure control operates on high pressure by starting and/stopping fan. Differential is fixed. (1kg/cm2 or 14 psi.) cut-off pressure must be 16 kg/cm2 (228 psi) low pressure values may cause gearbox malfunction. Pressure values higher than 16 kg...

  • Page 19

    19 maintenance and cleaning instructions important! **maintenance and cleaning procedures as well as problems derived from failing to carry them out are not covered by the warranty. Proper maintenance is essential to obtain favourable ice quality and optimum function of unit. Frequency depends on wa...

  • Page 20

    20 maintenance and cleaning procedures warning: unit should always be disconnected during maintenance/cleaning procedures. Water condenser 1) disconnect machine. 2) close water faucet. 3) disconnect water entry/exit from condenser. 4) prepare a solution of 50% phosphoric acid in distilled water. 5) ...

  • Page 21

    21 3) hold agitator paddles so that water pan releases water. 4) once the water pan returns to its horizontal position again, switch off the machine. Pour 3 litres of water and one half of di-caloid lr) into water pan 5) allow the solution to work for 20 or 30 minutes, occasionally turning the paddl...

  • Page 22

    22 checking for water leaks this must be done whenever maintenance is carried out on the machine: check all water connections, braces, tubes and hoses in order to eliminate leaks and prevent breakages and flooding. Check that the valve closes tightly on models with an automatic cleaning system. Spec...

  • Page 23

    23 troubleshooting problem possible causes solution 1) none of the electrics work. A) the machine is not plugged in. A) plug the machine. B) the line fuse has blown. B) replace fuse. C) the current line is wrongly connected in the junction box. C) check connections. D) the cut off micro-switch is fa...

  • Page 24

    24 problem possible causes solution 4) everything appears to be running correctly but no ice made in the evaporator. A) freezing system faulty. (dirty condenser, presostato o válvula entrada agua de condensación averiadas o mal reguladas o falta de refrigerante). A) check system. B) hot gas valve fa...

  • Page 25

    25 problem possible causes solution 11) pan does not free cubes or remains in am intermediary position. A) cam motor disconnected or in bad condition. A) y b) connect or replace cam motor. Always change pin and wheel. B) flexible pin or cam wheel broken. 12) pan goes up and down constantly. A) agita...