Basler BIP2-DXXXXc-dn User Manual - 1.2

Other manuals for BIP2-DXXXXc-dn: Installation Manual, User Manual
Manual is about: IP Fixed Dome Cameras

Summary of BIP2-DXXXXc-dn

  • Page 1

    Basler ip fixed dome cameras user’s manual for bip2-dxxxxc-dn models document number: aw001015 version: 10 language: 000 (english) release date: 13 january 2016.

  • Page 2

    Contacting basler support worldwide europe, middle east, africa basler ag an der strusbek 60–62 22926 ahrensburg germany tel. +49 4102 463 515 fax +49 4102 463 599 support.Europe@baslerweb.Com the americas basler, inc. 855 springdale drive, suite 203 exton, pa 19341 usa tel. +1 610 280 0171 fax +1 6...

  • Page 3

    Aw00101510000 table of contents basler ip fixed dome cameras i table of contents 1 introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 about this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 4

    Table of contents aw00101510000 ii basler ip fixed dome cameras appendix a software license information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 5: 1 Introduction

    Aw00101510000 introduction basler ip fixed dome cameras 1 1 introduction 1.1 about this document applicability this document applies to cameras that have the designation "bip2" as part of their model name. See the specification tables in chapter 8 on page 105 for a complete list of the camera models...

  • Page 6: 1.2

    Introduction aw00101510000 2 basler ip fixed dome cameras 1.2 precautions weee directive the european union has enacted directive 2002/96/ec on waste electrical and electronic equipment (the weee directive). This directive is only applicable in european union member states. All basler ip cameras hav...

  • Page 7: 1.3

    Aw00101510000 introduction basler ip fixed dome cameras 3 1.3 overview rj-45 network / poe - provides a 10/100 ethernet connection and can be used to connect power over ethernet (ieee 802.3af) to the camera. Main terminal block - provides connections for an alternate camera power input that can be u...

  • Page 8

    Introduction aw00101510000 4 basler ip fixed dome cameras status indicator leds - the green led indicates the network connection speed. Off means the network speed is 10 mbits/s (or the network is not connected). On means the network speed is 100 mbits/s. The yellow led indicates the level of networ...

  • Page 9: 2 Accessing The Camera

    Aw00101510000 accessing the camera basler ip fixed dome cameras 5 2 accessing the camera the following instructions assume that you have used the basler ip fixed dome camera installation guide (aw001014) to install your camera and that you know either the ip address or the host name of your camera. ...

  • Page 10: 3 Configuring The Camera

    Configuring the camera aw00101510000 6 basler ip fixed dome cameras 3 configuring the camera this chapter describes how to configure your camera. It is intended to be used by administrators who have full access rights to the camera. 3.1 introduction when adjusting the parameters used to configure th...

  • Page 11

    Aw00101510000 configuring the camera basler ip fixed dome cameras 7 streaming , motion detection, alarm handling, etc. Except for the streaming group, the parameters in each group can be adjusted while the camera is in normal mode. The parameters in the streaming group can only be adjusted when the ...

  • Page 12

    Configuring the camera aw00101510000 8 basler ip fixed dome cameras fig. 3: camera block diagram imaging sensor stream 0 encoder camera global parameters (sensor aoi and masks) image control parameters alarm parameters i/o parameters motion detection parameters system parameters stream 0 parameters ...

  • Page 13: 3.2

    Aw00101510000 configuring the camera basler ip fixed dome cameras 9 3.2 accessing the configuration tools and camera parameters.

  • Page 14

    Configuring the camera aw00101510000 10 basler ip fixed dome cameras 4. A camera configuration menu will open on the left side of the client as shown below. Notice that the parameters used to configure the camera appear in groups such as the image controls group and the streaming group. You can open...

  • Page 15

    Aw00101510000 configuring the camera basler ip fixed dome cameras 11 note that changing the refresh rate setting will not change the rate at which the camera captures or streams images. The refresh rate setting only affects the rate at which images are displayed in the web client in your browser. So...

  • Page 16

    Configuring the camera aw00101510000 12 basler ip fixed dome cameras note that the quality of the focusing result might be influenced by: object movements during the focusing process changes in lighting conditions low lighting level low temperature (note the ambient temperature restrictions mentione...

  • Page 17: 3.3

    Aw00101510000 configuring the camera basler ip fixed dome cameras 13 3.3 image control parameters the parameters in the image controls group control the quality of the images captured by the camera's imaging sensor. 3.3.1 exposure tab prioritize quality = automatic exposure time control and automati...

  • Page 18

    Configuring the camera aw00101510000 14 basler ip fixed dome cameras note that the operation of the automatic gain and exposure time controls will be strongly influenced by the placement of the auto brightness mask. For more information about the auto brightness mask,. Exposure offset - is used to c...

  • Page 19: 3.3.2

    Aw00101510000 configuring the camera basler ip fixed dome cameras 15 note that if automatic exposure time control is enabled, the exposure time parameter will be read-only and will indicate the current exposure time value as set by the automatic control. Gain limit - when automatic gain control is e...

  • Page 20

    Configuring the camera aw00101510000 16 basler ip fixed dome cameras auto preset = the camera will attempt to identify the type of lighting present (i.E., daylight, incandescent, fluorescent, etc.) and then will automatically adjust the white balance based on the lighting type detected. This selecti...

  • Page 21: 3.3.3

    Aw00101510000 configuring the camera basler ip fixed dome cameras 17 3.3.3 day/night tab note: detailed information about how the camera’s day/night functionality works. Basler recommends that you read this chapter before you set the parameters on the day/night tab. Ir filter state - indicates the c...

  • Page 22: 3.3.4

    Configuring the camera aw00101510000 18 basler ip fixed dome cameras ir filter wait time - sets the amount of time in seconds that the value of the ir filter current level must remain above the ir filter switch level setting before the camera will switch from day mode to night mode. It also sets the...

  • Page 23: 3.3.5

    Aw00101510000 configuring the camera basler ip fixed dome cameras 19 3.3.5 rtt tab the rtt tab offers similar parameters as the exposure and appearance tabs (see page 15 ) to allow the user to choose different settings for real-time triggered images. This is useful to account for different lighting ...

  • Page 24

    Configuring the camera aw00101510000 20 basler ip fixed dome cameras black level - sets a value for the black level compensation in order to achieve a higher contrast. A setting of 0 means no black level compensation will take place. At higher settings, the black level will be adjusted based on the ...

  • Page 25: 3.4

    Aw00101510000 configuring the camera basler ip fixed dome cameras 21 3.4 streaming parameters the parameters in the streaming group are used to control the characteristics of the image area that will be captured by the camera’s sensor. They are also used to control the characteristics of the video s...

  • Page 26: 3.4.1

    Configuring the camera aw00101510000 22 basler ip fixed dome cameras 3.4.1 global tab the parameters on the global tab control the way that the camera’s imaging sensor will capture images. Because the images captured by the sensor are used for all three video streams, the parameters on this tab are ...

  • Page 27

    Aw00101510000 configuring the camera basler ip fixed dome cameras 23 sensor aoi left - as shown in, sets the left offset (in pixels) for the sensor aoi, i.E., how far the sensor aoi will be offset from the left edge of the sensor. When you adjust this setting, you will notice that it must be changed...

  • Page 28

    Configuring the camera aw00101510000 24 basler ip fixed dome cameras test image mode - enables or disables the camera’s test image feature. When the test image mode is enabled, the camera will generate test images using its digital devices rather than the imaging sensor. The generated test images wi...

  • Page 29

    Aw00101510000 configuring the camera basler ip fixed dome cameras 25 in addition to the sensor aoi editor, there are the following 4 editors: white balance mask editor auto brightness mask editor privacy mask editor motion mask editor.

  • Page 30

    Configuring the camera aw00101510000 26 basler ip fixed dome cameras white balance mask - click the white balance mask button to open the white balance mask editor as shown below. The white balance mask defines the area(s) of the image that will be used by the camera’s automatic white balancing func...

  • Page 31

    Aw00101510000 configuring the camera basler ip fixed dome cameras 27 auto brightness mask - click the auto brightness mask button to open the auto brightness mask editor as shown below. The auto brightness mask defines the area(s) of the image that will be used by the camera when it performs automat...

  • Page 32

    Configuring the camera aw00101510000 28 basler ip fixed dome cameras privacy mask - click the privacy mask button to open the privacy mask editor as shown below. The privacy mask defines the area(s) of the image that will be blacked out in the images in the video streams. Only the areas highlighted ...

  • Page 33

    Aw00101510000 configuring the camera basler ip fixed dome cameras 29 motion mask - click the motion mask button to open the motion mask editor as shown below. The motion mask defines the area(s) of the image that will be used for the camera’s motion detection function. Only the areas highlighted in ...

  • Page 34

    Configuring the camera aw00101510000 30 basler ip fixed dome cameras mask editor tools to apply a mask, all editors use the same tools. These are arranged in a toolbar at the top of each editor’s tab. With the tools, you can mask the entire sensor area, a single area or several different areas withi...

  • Page 35: 3.4.2

    Aw00101510000 configuring the camera basler ip fixed dome cameras 31 3.4.2 stream tabs the parameters on the stream 0 tab, stream 1 tab,and stream 2 tab control the way that the video stream associated with the selected tab is configured. This section describes the settings on the stream 0 tab, the ...

  • Page 36

    Configuring the camera aw00101510000 32 basler ip fixed dome cameras encoder type - sets the video encoder type for the stream. Off = the video stream is disabled and no images will be streamed. This setting is only available on the stream 1 and stream 2 tabs. Stream 0 is always enabled, and the off...

  • Page 37

    Aw00101510000 configuring the camera basler ip fixed dome cameras 33 encoder type - (continued from previous page) yuv (rt triggered) = the camera will use the i420 color format for outputting uncompressed yuv images. The output will be an http stream. Live recording is also supported. This encoder ...

  • Page 38

    Configuring the camera aw00101510000 34 basler ip fixed dome cameras if the encoder mode parameter is set to capped vbr, you can also set the desired quality of the stream by using the quality parameter. Note that the effect of the quality setting is not precisely equivalent for each encoder type. F...

  • Page 39

    Aw00101510000 configuring the camera basler ip fixed dome cameras 35 output size - lets you select from a list of standard image sizes. When you select a size, the camera checks the setting of the output scaling parameter. It then automatically sets the stream aoi left , stream aoi top, stream aoi w...

  • Page 40

    Configuring the camera aw00101510000 36 basler ip fixed dome cameras stream aoi height - as shown in, sets the height (in pixels) of the stream aoi. When you adjust this setting, you will notice that it must be changed in certain fixed increments. * * you can also use the stream aoi editor to set th...

  • Page 41

    Aw00101510000 configuring the camera basler ip fixed dome cameras 37 of the buffer that is allocated for post alarm image storage is full (see the next parameter). At that point, buffering will stop, and the pre and post alarm images held in the buffer will be retained until a new alarm buffer arm c...

  • Page 42

    Configuring the camera aw00101510000 38 basler ip fixed dome cameras overlay text - sets the text that will appear in the text overlay. You can enter simple strings of text, and you can also enter the following expressions: = display the current date, time, and time zone (see to set the current date...

  • Page 43

    Aw00101510000 configuring the camera basler ip fixed dome cameras 39 overlay position - sets the position of the text overlay. Top left = place the text overlay bar at the top left of each streamed image. Bottom left = place the text bar at the bottom left of each image. Top right = place the text o...

  • Page 44

    Configuring the camera aw00101510000 40 basler ip fixed dome cameras view current overlay image - click the view current overlay image button to view the current overlay image in the camera. Upload new overlay image - click the upload new overlay image button to upload a new png file as an overlay i...

  • Page 45

    Aw00101510000 configuring the camera basler ip fixed dome cameras 41 stream aoi editor - whenever a stream tab is selected, a stream aoi editor screen will also be available as shown below. Rather than setting numbers in the boxes on the stream tab, you can use the editor to set the aoi size and pos...

  • Page 46: 3.5

    Configuring the camera aw00101510000 42 basler ip fixed dome cameras 3.5 motion detection parameters the parameters in the motion detection group are used to control the operation of the camera’s motion detection function. To understand what the parameters in this group do, you should have a basic i...

  • Page 47

    Aw00101510000 configuring the camera basler ip fixed dome cameras 43 motion threshold - sets a threshold for motion detection. If the number of changed pixels in the current image is above the motion threshold and below the motion limit (see the next parameter), then motion will be detected. Motion ...

  • Page 48: 3.6

    Configuring the camera aw00101510000 44 basler ip fixed dome cameras 3.6 alarm handling parameters the parameters in the alarm handling group are used to select the sources that can declare an alarm condition and to control the actions that will be taken when an alarm condition is declared. 3.6.1 al...

  • Page 49

    Aw00101510000 configuring the camera basler ip fixed dome cameras 45 motion tab cyclic tab heartbeat missing tab source enable - check the source enable box on the motion tab to enable motion detection as a source for declaring an alarm condition. If motion detection is enabled as an alarm source an...

  • Page 50: 3.6.2

    Configuring the camera aw00101510000 46 basler ip fixed dome cameras 3.6.2 alarm buffers section each video stream can have an alarm buffer. Normally, the alarm buffer on a stream is simply a ring buffer that stores the last n captured images for the stream (n depends on the size of the images being...

  • Page 51: 3.6.3

    Aw00101510000 configuring the camera basler ip fixed dome cameras 47 3.6.3 alarm actions section the alarm actions section of the alarm handling parameters is used to control the actions that will be taken when an alarm condition is declared. Digital output tab digital output hold time [ms] - sets t...

  • Page 52

    Configuring the camera aw00101510000 48 basler ip fixed dome cameras email password - enter a password for authentication on the smtp server. Up to 29 characters can be used. All standard keyboard characters are valid. Email from - enter an email address to appear as the sender’s address in the emai...

  • Page 53

    Aw00101510000 configuring the camera basler ip fixed dome cameras 49 motionlevel_0= = current motion level (number of changed pixels) in region 0. The parameter descriptions for the remaining parameters motionregion_1/motionlevel_1 to motionregion_4/motionlevel_4 are identical to the motionregion_0/...

  • Page 54

    Configuring the camera aw00101510000 50 basler ip fixed dome cameras ftp password - enter a password for authentication on the ftp server. Up to 29 characters can be used. All standard keyboard characters are valid. Live recording tab the storage requirement in the live buffer for saving pre-alarm d...

  • Page 55

    Aw00101510000 configuring the camera basler ip fixed dome cameras 51 sd card tab include stream - check the include stream box to save video files to the sd card along with the text file. The video files will contain the pre-alarm and post-alarm images that were saved in the alarm buffers when the a...

  • Page 56: 3.7

    Configuring the camera aw00101510000 52 basler ip fixed dome cameras 3.7 live recording parameters the parameters in the live recording group are used to configure the settings for saving live recording data to an sd card or to an ftp server. 3.7.1 stream tabs the parameters on the stream 0 tab, str...

  • Page 57: 3.7.2

    Aw00101510000 configuring the camera basler ip fixed dome cameras 53 storage location - sets the location where the live stream should be saved. Sd card = the live stream will be saved to an sd card. For information about the sd card settings, see page 53 . Ftp server = the live stream will be saved...

  • Page 58: 3.7.3

    Configuring the camera aw00101510000 54 basler ip fixed dome cameras show sd card contents - click the show sd card contents button to access the sd card’s file structure via an ftp server that is built into the camera. When you click the button, the browser will open a new window, will connect to t...

  • Page 59: 3.8

    Aw00101510000 configuring the camera basler ip fixed dome cameras 55 3.8 network parameters the parameters in the network group are used to set the camera’s ip configuration. 3.8.1 settings tab ip address - assigns an ip address to the camera that will be used if dhcp addressing is disabled. Network...

  • Page 60: 3.8.2

    Configuring the camera aw00101510000 56 basler ip fixed dome cameras search domain - sets the domain names the camera will use for resolving non-fully qualified host names via dns lookups. Multiple domain names can be defined, which have to be separated by a space. Http port - sets the http port on ...

  • Page 61: 3.8.3

    Aw00101510000 configuring the camera basler ip fixed dome cameras 57 commit - click the commit button to save any changes you have made to the rtsp settings. Revert - click the revert button to cancel any changes you have made to the rtsp settings. The settings will revert to what they were the last...

  • Page 62: 3.8.5

    Configuring the camera aw00101510000 58 basler ip fixed dome cameras 3.8.5 snmp tab 3.8.6 onvif tab snmp enable - check the snmp enable box to enable the camera’s snmp agent. This agent is used to receive information via the simple network management protocol (snmp) from a "manager", e.G. An externa...

  • Page 63: 3.9

    Aw00101510000 configuring the camera basler ip fixed dome cameras 59 3.9 input / output parameters the parameters in the input/output group are used to configure the camera’s digital i/o ports and to configure the camera’s rs-485 serial port. 3.9.1 digital i/o tab i/o sub-tabs direction - sets wheth...

  • Page 64

    Configuring the camera aw00101510000 60 basler ip fixed dome cameras external trigger = the external trigger function is used to control the exposure start without having to use any other parameters. If the function parameter of an input port is set to "external trigger" and no external trigger is a...

  • Page 65

    Aw00101510000 configuring the camera basler ip fixed dome cameras 61 whether your camera falls into one of these categories, refer to the specification tables in chapter 8 on page 105 . For general information about shutters, see section 3.9.1.1. Flash window - this option is only available for came...

  • Page 66

    Configuring the camera aw00101510000 62 basler ip fixed dome cameras the cameras provide an exposure active output signal that will go active when the exposure time for a frame acquisition begins and will go inactive when the exposure time ends. Rolling shutter on cameras equipped with a rolling shu...

  • Page 67

    Aw00101510000 configuring the camera basler ip fixed dome cameras 63 using the flash window (rolling shutter) to provide the best-possible lighting conditions, apply the additional lighting during the "flash window" of each frame. The flash window is the period of time during a frame acquisition whe...

  • Page 68

    Configuring the camera aw00101510000 64 basler ip fixed dome cameras you can calculate when the flash window will open (i.E., the time from the frame trigger until the moment when the window opens) using the following formula: time to flash window open = trow x (h - 1) where h = sensor height (user-...

  • Page 69

    Aw00101510000 configuring the camera basler ip fixed dome cameras 65 using exposure active (rolling shutter) when the strobe mode parameter is set to "exposure active", the camera sends a signal on the digital output port that can be used to control an external light source in order to provide addit...

  • Page 70: 3.9.2

    Configuring the camera aw00101510000 66 basler ip fixed dome cameras 3.9.2 serial i/o tab the parameters on the serial i/o tab are used to configure the camera’s rs-485 serial port. Line configuration - sets the line configuration for the serial port in data bits, parity, stop bit format. For exampl...

  • Page 71: 3.10 User Parameters

    Aw00101510000 configuring the camera basler ip fixed dome cameras 67 3.10 user parameters the parameters in the user group are used to manage user authentication on the camera. 3.10.1 enabling authentication and logging in for the first time anonymous viewer enabled - check the anonymous viewer enab...

  • Page 72

    Configuring the camera aw00101510000 68 basler ip fixed dome cameras 3.10.2 logging in and logging out once you have logged into the camera, a logged in: indicator, a change password button, and a logout button (shown circled in red below) will appear in the basler toolbar. Notice that the logged in...

  • Page 73: 3.10.3 Managing Users

    Aw00101510000 configuring the camera basler ip fixed dome cameras 69 3.10.3 managing users to manage users, you must be logged into the camera as an administrator. Once you are logged in, access the user parameters group, and click on the manage users button. A user management tab will appear as sho...

  • Page 74

    Configuring the camera aw00101510000 70 basler ip fixed dome cameras to add a new user 1. Click the new user button on the user management tab. A user editor window will appear as shown below. 2. Enter a user name, select a user level (see), enter a password, reenter the password to verify, and clic...

  • Page 75

    Aw00101510000 configuring the camera basler ip fixed dome cameras 71 4. A success message window will open. Click the ok button. To change an existing user’s password 1. On the user management tab, click the name of the user whose password you wish to change. As shown below, the user information wil...

  • Page 76

    Configuring the camera aw00101510000 72 basler ip fixed dome cameras to change an existing user’s user level 1. On the user management tab, click the name of the user whose user level you wish to change (see for user level descriptions). As shown below, the user information will become highlighted, ...

  • Page 77: 3.11 Audio Parameters

    Aw00101510000 configuring the camera basler ip fixed dome cameras 73 3.11 audio parameters the parameters in the audio group are used to configure the camera’s audio functionality. The audio data can be streamed via http or rtsp together with mjpeg, mpeg-4, and h.264 encoded streams. For information...

  • Page 78: 3.12 System Parameters

    Configuring the camera aw00101510000 74 basler ip fixed dome cameras 3.12 system parameters the parameters in the system group provide some basic information about the camera and allow you to set basic system characteristics such as the date and time. 3.12.1 info tab 3.12.2 date/time tab the followi...

  • Page 79

    Aw00101510000 configuring the camera basler ip fixed dome cameras 75 time zone description - sets the time zone. Select the correct time zone for the camera’s location from the drop down list. External clock synchronization - enables or disables clock synchronization and sets the synchronization met...

  • Page 80: 3.12.3 Management Tab

    Configuring the camera aw00101510000 76 basler ip fixed dome cameras ntp server source - determines the way the ntp server parameter will be set. Dhcp = the camera receives the ip address or name of the ntp server to use from a dhcp server response, if available. Manual = you must manually set the i...

  • Page 81

    Aw00101510000 configuring the camera basler ip fixed dome cameras 77 config management - use the config management button to save the camera’s current parameter settings to a file on your pc or to upload a saved configuration file from your pc to the camera. To save the current parameter settings to...

  • Page 82

    Configuring the camera aw00101510000 78 basler ip fixed dome cameras 4. In the save as dialog box, select a location where the file will be saved, enter a file name (basler recommends using .Cfg as the file name extension), and click the save button. 5. When the download complete screen appears, cli...

  • Page 83

    Aw00101510000 configuring the camera basler ip fixed dome cameras 79 start firmware update - occasionally, firmware updates may be made available to the field. The start firmware update button is used to start the firmware update process. To determine the version of the firmware currently in your ca...

  • Page 84

    Configuring the camera aw00101510000 80 basler ip fixed dome cameras 2. Click the ok button in the start firmware upload dialog box. A web page will open indicating that camera operation has been stopped. 3. Use the browse button in the window to select the new firmware file that you want to load on...

  • Page 85

    Aw00101510000 configuring the camera basler ip fixed dome cameras 81 4. Make sure that the firmware is correct and then click the confirm update button. A web page indicating the progress will appear. Wait for the update to finish. A web page will appear indicating that the update is finished. 5. Cl...

  • Page 86: 4 Factory Default Button

    Factory default button aw00101510000 82 basler ip fixed dome cameras 4 factory default button a factory defaults button is available on the side of the camera as shown below. The factory defaults button is especially useful if you have enabled user management on the camera and you can no longer reme...

  • Page 87: Connector

    Aw00101510000 terminal blocks and audio connector basler ip fixed dome cameras 83 5 terminal blocks and audio connector 5.1 the main terminal block the terminal block on the front of the camera base can be used to: provide alternate power to the camera when poe is not used (this functionality is ava...

  • Page 88

    Terminal blocks and audio connector aw00101510000 84 basler ip fixed dome cameras the assignments for the wire fixing holes in the main terminal block are as shown below and explained in table 3 on page 85. Fig. 10: main terminal block the main terminal block is a push-in type of connector. Either s...

  • Page 89

    Aw00101510000 terminal blocks and audio connector basler ip fixed dome cameras 85 the functionality of each wire fixing hole in the main terminal block is as described in table 3. Hole name: gnd (outdoor dome cameras only) function: ground for alternate camera power. Note: the ground for alternate c...

  • Page 90

    Terminal blocks and audio connector aw00101510000 86 basler ip fixed dome cameras hole name: i/o-0, i/o-1 function: i/o port 0 and i/o port 1 respectively. Each i/o port can be set to operate either as an input or as an output. The choice of whether a particular i/o port will operate as an input or ...

  • Page 91

    Aw00101510000 terminal blocks and audio connector basler ip fixed dome cameras 87 hole name: dc out function: dc out supplies unregulated +5.6 vdc and can be used to power a small device such as a relay. The maximum allowed load on dc out is 50 ma. If an inductive load such as a relay is used with d...

  • Page 92

    Terminal blocks and audio connector aw00101510000 88 basler ip fixed dome cameras fig. 11: i/o, alternate power, and rs-485 schematic rs-485 gnd (isolated) b- a+ dc out vdc camera power gnd (isolated) +12 to +24 vdc +24 vdc max switch device rs-485 gnd rs-485 a+ rs-485 b- camera +5 vdc +5 vdc 1 kΩ (...

  • Page 93: 5.2

    Aw00101510000 terminal blocks and audio connector basler ip fixed dome cameras 89 5.2 the rs-485 terminal block the 3-hole terminal block on the right side of the camera base can be used to make an rs-485 connection to the camera. The assignments for the wire fixing holes in the terminal block are a...

  • Page 94: 5.3

    Terminal blocks and audio connector aw00101510000 90 basler ip fixed dome cameras 5.3 the audio connector 5.3.1 audio connector type and pin assignments the audio connector on the camera is a 4-pin jst phr-4 type connector. The pin numbering is as shown in figure 13. Fig. 13: audio connector the pin...

  • Page 95: 5.3.2

    Aw00101510000 terminal blocks and audio connector basler ip fixed dome cameras 91 5.3.2 audio y-cable a y-cable for use with the audio connector is shipped with the camera. The cable is equipped with the connectors shown in figure 14. If desired, you can use the information that appears in this sect...

  • Page 96: 5.3.3

    Terminal blocks and audio connector aw00101510000 92 basler ip fixed dome cameras 5.3.3 audio schematic a schematic for mic-in / line-in and for line-out is shown in figure 15. As shown in the schematic, software switchable mic-power is available on mic-in / line-in. The specifications for mic-power...

  • Page 97: 6 Day/night Functionality

    Aw00101510000 day/night functionality basler ip fixed dome cameras 93 6 day/night functionality 6.1 introduction basler ip fixed dome cameras are equipped with day/night functionality. Cameras with day/night functionality are well-suited for use in areas with natural lighting during the day and arti...

  • Page 98

    Day/night functionality aw00101510000 94 basler ip fixed dome cameras ir-cut filter modes of operation the ir-cut filter mechanism in the camera has several modes of operation. You can use the day/night tab in the image controls parameters group (see) to set the ir filter mode. The modes of operatio...

  • Page 99

    Aw00101510000 day/night functionality basler ip fixed dome cameras 95 auto controls from mistakenly sensing a momentary change in lighting conditions as a change from night to day or from day to night. Finally, the ir filter current level parameter lets you see the current darkness level as measured...

  • Page 100: 6.2

    Day/night functionality aw00101510000 96 basler ip fixed dome cameras 6.2 ir-cut filter control options controlling the ir-cut filter position via a digital i/o port as mentioned in, the ir-cut filter can be set for several different modes of operation. If you set the ir-cut filter mode parameter to...

  • Page 101

    Aw00101510000 day/night functionality basler ip fixed dome cameras 97 fig. 16: input used to control ir-cut filter position illuminator internal switch associated with a photocell rs-485 gnd (isolated) b- a+ dc out vdc camera power gnd (isolated) camera +5 vdc +5 vdc 1 kΩ (set as an output) (set as ...

  • Page 102

    Day/night functionality aw00101510000 98 basler ip fixed dome cameras controlling an external device based on the ir-cut filter position as mentioned, the camera includes a capability called the ir-cut filter announce feature. When this feature is enabled, the camera will "announce" the current posi...

  • Page 103

    Aw00101510000 day/night functionality basler ip fixed dome cameras 99 fig. 17: output used to apply device power relay illuminator power illuminator rs-485 gnd (isolated) b- a+ dc out vdc camera power gnd (isolated) camera +5 vdc +5 vdc 1 kΩ (set as an output) (set as an input) i/o-0 i/o-1 1 kΩ heat...

  • Page 104: 7 Real-Time Trigger

    Real-time trigger functionality aw00101510000 100 basler ip fixed dome cameras 7 real-time trigger functionality 7.1 introduction the camera normally captures images without the need for any type of triggering by the user. For instance, if a camera is set for a frame rate of 30 frames (images) per s...

  • Page 105

    Aw00101510000 real-time trigger functionality basler ip fixed dome cameras 101 1/30 s 1/30 s 1/30 s 1/30 s 1/30 s camera controlled capture 1 camera controlled capture 2 camera controlled capture 3 camera controlled capture 6 camera controlled capture 7 camera controlled capture 4 camera controlled ...

  • Page 106

    Real-time trigger functionality aw00101510000 102 basler ip fixed dome cameras if you take a close look at figure 19, you will notice that two of the image captures triggered by the camera’s internal process were aborted. These two partially completed images will be dropped and will not be transmitt...

  • Page 107: 7.2

    Aw00101510000 real-time trigger functionality basler ip fixed dome cameras 103 7.2 enabling and using real-time triggering to enable real-time triggering, use the digital i/o tab in the input/output parameters group (see section 3.9 on page 59 ) to properly configure one of the i/o ports. The port s...

  • Page 108: 7.3

    Real-time trigger functionality aw00101510000 104 basler ip fixed dome cameras 7.3 real-time triggering impact on streams when you are setting the streaming group parameters on the camera, remember that because the real-time trigger operates at the sensor level, it impacts all enabled streams. So, f...

  • Page 109: 8 Technical Specifications

    Aw00101510000 technical specifications basler ip fixed dome cameras 105 8 technical specifications 8.1 bip2-d1000c-dn and bip2-d1300c-dn specification bip2-d1000c-dn bip2-d1300c-dn sensor 1/3" progressive scan ccd global shutter effective pixels 1024 (h) x 768 (v) 1280 (h) x 960 (v) pixel size 4.65 ...

  • Page 110

    Technical specifications aw00101510000 106 basler ip fixed dome cameras audio bidirectional half-duplex audio streaming mic-in/line-in, line-out g.711 (8 bit, 8 khz) pcm raw (16 bit, 16 khz) alarm management ring buffer for pre and post alarm images microsdhc card slot for local storage (microsdhc c...

  • Page 111: 8.2

    Aw00101510000 technical specifications basler ip fixed dome cameras 107 8.2 bip2-d1920c-dn (outdoor)/(outdoor, af) and bip2-d1920c-dn (indoor)/(indoor, af) specification bip2-d1920c-dn (outdoor) / bip2-d1920c-dn (outdoor, af) bip2-d1920c-dn (indoor) / bip2-d1920c-dn (indoor, af) sensor 1/3" progress...

  • Page 112

    Technical specifications aw00101510000 108 basler ip fixed dome cameras alarm management ring buffer for pre and post alarm images microsdhc card slot for local storage (microsdhc card is not included with the camera) events triggered by motion detection or external input image upload via ftp, email...

  • Page 113

    Aw00101510000 technical specifications basler ip fixed dome cameras 109 standards fcc class a, ce, rohs, onvif the ce conformity declaration is available on the basler website: www.Baslerweb.Com housing ∅ 148 mm x 122 mm (∅ 5.83" x 4.8") vandal-proof aluminum chassis with polycarbonate dome bubble, ...

  • Page 114: 8.3

    Technical specifications aw00101510000 110 basler ip fixed dome cameras 8.3 dimensions fig. 20: dimensions in mm (inches).

  • Page 115

    Aw00101510000 software license information basler ip fixed dome cameras 111 appendix a software license information mpeg-4 this product is licensed under the mpeg-4 visual patent portfolio license for the personal and non-commercial use of a consumer for (i) encoding video in compliance with the mpe...

  • Page 116

    Software license information aw00101510000 112 basler ip fixed dome cameras other software the camera contains software originating from a variety of third parties. To view the software license information: 1. Start the ip camera web client as described in chapter 2 on page 5 . 2. Click the about ta...

  • Page 117

    Aw00101510000 revision history basler ip fixed dome cameras 113 revision history doc. Id number date changes aw00101501000 16 jun 2011 initial release of this document. Aw00101502000 27 jul 2011 added information for the new bip2-d1920c-dn and bip2-d1920c-dn (indoor) models. Aw00101503000 30 aug 201...

  • Page 118

    Revision history aw00101510000 114 basler ip fixed dome cameras aw00101505000 31 jul 2012 added the description of the new audio encoder type parameter (see page 37 ). Added the description of the new parameters pre-alarm time period [s] and post-alarm time period [s] to the live recording tab in th...

  • Page 119

    Aw00101510000 revision history basler ip fixed dome cameras 115 aw00101506000 3 apr 2014 updated the support contact information in the contacting basler support worldwide section (see page 2 ). Updated the frame rate mode parameter description (see page 23 ). Updated mask editor descriptions (see p...

  • Page 120

    Revision history aw00101510000 116 basler ip fixed dome cameras (continued from previous page) removed the ntp parameter in the system parameter group. Added information about maximum length of unshielded cables (see page 84 ). Updated the i/o, alternate power, and rs-485 schematic (see page 88 ). A...

  • Page 121

    Aw00101510000 index basler ip fixed dome cameras 117 index a adding a user............................................70 alarm actions ............................................47 alarm buffer size parameter .....................37 alarm buffer state parameter ....................46 alarm buffers ...

  • Page 122

    Index aw00101510000 118 basler ip fixed dome cameras focus tab ..................................................18 forwarding mode ......................................66 forwarding parameter ...............................66 forwarding, serial port ..............................66 frame rate imag...

  • Page 123

    Aw00101510000 index basler ip fixed dome cameras 119 mirror ........................................................23 mjpeg .....................................................32 model name parameter ............................74 motion detection mode parameter............42 motion detection para...

  • Page 124

    Index aw00101510000 120 basler ip fixed dome cameras sensor aoi height parameter ...................23 sensor aoi left parameter........................23 sensor aoi top parameter........................23 sensor aoi width parameter ....................23 serial i/o tab.................................