Bionic Fire RAIS User Manual - page 21
21
The appliance must be serviced and maintained using parts approved by the
manufacturer, to achieve the proper performance of the appliance.
9. Interruption of operation
9.1. Smoke spillage around the door
It could be due too low draught in the chimney
Check whether the flue or chimney is blocked
Check whether the extraction hood is switched on. If it is, switch it off and open a
window or door in the proximity of the stove for a short while.
9.2 Soot on glass
It could be caused by too wet firewood.
Make sure that the stove is heated properly when firing up, prior to closing the door.
9.3 Stove is burning too strong
It could be caused by:
Leak around the door seal
Chimney draught is too large > 22 Pa; draught regulator should be installed
9.4 Stove is burning too weakly
It could be caused by:
Too small amount of firewood
Too little air supply for room ventilation
Unclean smoke channels
Leaky chimney
Leakage between chimney and flue
If the stove continues to malfunction, we recommend that you contact your RAIS distributor
or you chimney sweep.
Warning!
In case of a chimney fire:
Shut off all air supply from outside (if installed) to the stove
Contact the fire department
Never attempt to put out the fire with water!
Afterwards, you should ask your chimney sweep to check the stove and chimney