BIONIME rightest GM700S User Manual

Summary of rightest GM700S

  • Page 1

    101-3gm780-011 en rev . Da te: s ept ember/2014 bionime gmbh tramstrasse 16, 9442 berneck switzerland e-mail: info@bionime.Ch gm700s 0197 bionime corporation no. 100, sec. 2, daqing st., south dist., taichung city 40242, taiwan tel: +886 4 2369 2388 fax: +886 4 2261 7586 http: //www.Bionime.Com e-ma...

  • Page 3

    Preface 3 2 preface the blood glucose monitoring system is a personal blood glucose monitoring system to be used for self-testing only. It is not recommended for multiple users. The testing result is calibrated to be plasma equivalent for test with fresh capillary, venous, arterial and neonatal whol...

  • Page 4

    - avoid contact with dripping or splashing liquids. - the minimum blood sample size to test using the blood glucose monitoring system is 0.75µl: ( ) tm rightest gm700s 5 4 caution caution blood sample size above 3.0µl might contaminate the test strip port and the meter. Blood sample size below 0.75µ...

  • Page 5

    7 6 table of contents table of contents about the blood glucose monitoring system the blood glucose monitoring system ............................................................ The blood glucose meter ................................................................................ The blood glucos...

  • Page 6

    9 8 10* 5 3 * 2 6 * 1 contents your blood glucose monitoring system gm700s consists of several items. Please identify each item, learn its name and how it is used. Below are the items included in your blood glucose monitoring system gm700s: 1. Getting started guide 2. User's manual (includes log boo...

  • Page 7

    Gm700s 11 10 the blood glucose meter tm rightest gm700s right button ( ) battery cover meter battery the blood glucose meter tm rightest gm700s left button ( ) main button ( ) display window test strip port 2d barcode with serial number.

  • Page 8

    13 12 the blood glucose meter tm rightest gm700s the blood glucose meter tm rightest gm700s indicates a test result stored in memory indicates a test result not included into the average results of the meter indicates the average result indicates a control solution test result unit of test result te...

  • Page 9

    15 14 the blood glucose meter g 700s can only be used with blood glucose test strips gs700 and control solution gc700. The use of other test strips or control solutions can lead to incorrect results. Tm tm rightest m rightest tm rightest precaution - close the lood glucose test strip gs700 vial imme...

  • Page 10

    17 16 meter activation and battery change your blood glucose meter comes with one cr2032, 3volt, batteries installed. New batteries will provide power to perform approximately 1000 tests under normal use. Press the main button or insert a strip to activate your meter. Tm rightest one gm700s 17 meter...

  • Page 11

    19 18 note - use the left and right buttons to select your setting data and press the main button to confirm each selection. After confirming all of the settings, you will return to the time mode. You can enter the setting mode two ways. 1. Replace the battery 2. With battery inserted after removing...

  • Page 12

    21 20 4. Time format 12/24h selection with the time format blinking, press the left or right button to switch between 12h and 24h. Press the main button to confirm. 5. Hour setting with the hour blinking, press the left or right button until you see the current hour. Press the main button to confirm...

  • Page 13

    23 22 1. How to turn on the blood glucose meter press the main button or insert a test strip. 2. Manual power off to power off the blood glucose meter , press and hold the main button for 3 seconds. 3. Auto power off tm rightest tm rightest tm the rightest blood glucose meter will power off automati...

  • Page 14

    Gm700s 25 24 handling the blood glucose test strip tm rightest gs700 removing the blood glucose test strip : 1. Hold the blood glucose test strip as shown. 2. Rotate the blood glucose test strip counterclockwise and pull up simultaneously. Tm rightest tm rightest tm rightest gs700 gs700 gs700 3. Tak...

  • Page 15

    27 26 performing a blood glucose test 1. Hold the depth adjustable cap in one hand and hold the base with the other hand. Bend the cap down. When a gap appears between the cap and base, pull the cap and base in opposite directions. 2. Pull off the depth adjustable cap. 3. Insert a new disposable lan...

  • Page 16

    29 performing a blood glucose test 12. A blood drop icon will appear on the display window and will be accompanied by a beep (if volume is turned on). Apply the blood sample within 2 minutes. 13. Place the lancing device against your fingertip and press the release button. 14. Touch and hold the blo...

  • Page 17

    31 30 performing a blood glucose test caution - do not apply your blood drop to the sample port on the strip until you see the " " appear. The blood glucose meter is performing an internal test and will display " " and " " if you apply blood too soon. If this occurs, please repeat the test with a ne...

  • Page 18

    33 32 alternative site testing caution - test results may vary if blood samples are taken from different sites or under certain conditions where glucose levels are changing rapidly such as: following a drink, a meal, an insulin dose or exercise. In these cases, only the fingertip should be used. - d...

  • Page 19

    35 34 view window appearance understanding test results and messages if your blood glucose result is unusually high or low, or if you question your test results, repeat the test with a new blood glucose test strip gs700. You can also run a quality control test with the control solutions gc700 to che...

  • Page 20

    37 36 understanding test results and messages about quality control testing what is a quality control test ? To ensure proper monitoring function, it is necessary to regularly perform a quality control test. Use one of the control solutions gc700 when testing your blood glucose monitoring system gm7...

  • Page 21

    39 38 about quality control testing about quality control testing caution - each time you open a new bottle of control solution, write the expiration date on the label. The control solution gc700 is good for 3 months after opening the bottle, or until the expiration date printed on the label, whiche...

  • Page 22

    41 40 performing a quality control test 9. Tightly replace the cap on the control solution gc700 bottle. 10. The control solution result will appear. Compare your quality control test result to the control solution range printed on the blood glucose test strip gs700 vial label. Tm rightest tm righte...

  • Page 23

    43 42 understanding control test results recalling test results the blood glucose meter is able to automatically store a maximum of 500 test results with time and date. If your meter has stored 500 results, the newest test result will replace the oldest one. To recall your test memory, start the met...

  • Page 24

    45 44 recalling average test results 5. Quick searching: to view test results in sequential order automatically, enter the memory mode. Press the right or left button for 2 seconds. (the right button is for viewing from the most current to the oldest test results. The left button is for viewing from...

  • Page 25

    47 46 caring for your meter maintenance keep your meter and test strip free of dust, water or any other liquid. Store the meter in the carrying case when not in use. If your meter is dropped or damaged, perform a quality control test with the control solution before performing a blood glucose test. ...

  • Page 26

    49 48 er1 - er2 - the m er3 - the s the inserted test strip has been used or damaged. Please use a new test strip. Eter has malfunctioned. Do a quality control test or reinstall the batteries to check if the meter works properly. Ignal transmission is disrupted. Repeat the test using a new test stri...

  • Page 27

    51 50 limitations error messages and troubleshooting - blood glucose monitoring system gm700s is not intended for serum or plasma testing. - severe dehydration and excessive water loss may cause inaccurately low results. - the glucose test may be invalid in the presence of abnormally high concentrat...

  • Page 28

    53 52 specification specification hematocrit power supply battery life meter dimension meter weight monitor display area meter storage/ transportation conditions test strip storage/ transportation conditions 10-70% one cr2032 batteries (3 voltage) approximately 1000 standard tests 82 mm x 45 mm x 15...

  • Page 29

    55 54 customer service warranty we sincerely like to provide complete, considerate services to our customers. Please review all the instructions to make sure you are performing the steps correctly. If you have any questions or in case of problems with the products, please contact your local bionime ...

  • Page 30

    57 56 component manufacturer information expected glucose values without diabetes blood glucose meter, test strip, control solution manufacturer: bionime corporation no. 100, sec. 2, daqing st., south dist., taichung city 40242, taiwan product complies with in vitro diagnostic medical device directi...