BioZone Scientific International BIOZONE Owner's Manual - page 3
Unit Components (Figure AA.)
A. Service Cover
B. Service Cover Screw
C. Lamp Connector
D. Status Light
E. Lamp Life Reset Port
F. Lamp Seal
G. Status Light Remote Connection
H. Power Connection
I. UV-Lamp
J. Plasma Ports
K.12VDC 25W Power Adapter
L. Mounting Screws / Rivets
M. Plasma Distribution Tubing
N. Plasma Distribution Fittings
Before installation
Check that the aforementioned components are included in the package (some
are inside the device). In the event that something is missing, contact your
supplier.
Inspect the device for damage that may have occurred during transportation. If
the unit has been damaged, do not connect it to the power supply. In the event of damage,
immediately inform the dispatcher or retailer.
Check whether the manufacturer of the ice-machine has verified the compatibility
of the ice-machine with IceZone and recommended a suitable location for the
IceZone unit. If so, comply fully with the manufacturer’s instructions.
Only a maintenance mechanic or appropriately qualified person may install the
IceZone.
The installation may not be carried out in such a way that it damages electronic
components, ice-machine components or wiring. Furthermore, installation must
not require any modification to or re-positioning of ice-machine components.
This installation instruction including the positioning of the plasma ports and use of NSF
approved materials must be followed carefully to preserve the NSF compliance of the ice
machine. The intention is to maintain the integrity of the ice machine’s boundary between the
food zone and mechanical section by using sealed fittings whenever the plumbing must pass
through this boundary.
ATTENTION: Before installation, disconnect the ice-machine from the power supply.
Installation instructions