Bircher Reglomat PrimeMotion B Original Instructions

Summary of PrimeMotion B

  • Page 1

    1 prime motion b observe the national and international regulations on door safety. Only trained, qualified personnel may mount and start up the detector. The unit may only be opened and repaired by bircher reglomat. The unit may only be operated from a safety extra-low voltage (selv) system with sa...

  • Page 2

    5 configuration by hand dip-switch and potentiometer radar functions description field size 1 = smallest radar field (led flashes once), 2 ......., 3* = medium radar field (flashes 3 times), 4 ......, 5 = largest radar field size (flashes 5 times) direction recognition 1 on 2 3 4 on = both direction...