To prevent possible SERIOUS INJURY OR DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY OR DEATH from a
closing garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5m), and away
from ALL moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Drywall Anchors
Insulated
Staples
Screw 6ABx1-1/2"
Lighted Door Control Button
INSTALLATION STEP 6
Install the Door Control
Locate the door control within sight of the door at a minimum
height of 5 feet (1.5 m) where small children cannot reach, and
away from all moving parts of the door and door hardware.
1. Strip 1/4" (6 mm) of insulation from one end of the bell wire.
Connect it to the two screw terminals on the back of the door
control by color: white wire to 2 and white/red wire to 1.
2. Fasten the Lighted Door Control Button securely with
6ABx1-1/2" screws. If installing into drywall, drill 5/32" holes
and use the anchors provided.
3. Run the bell wire up the wall and across the ceiling to the
opener. Use insulated staples to secure the wire in several
places. Do not pierce wire with a staple, creating a short or
open circuit.
4. Receiver terminal screws and the antenna are located on the
back panel of the opener. Position the antenna wire as shown.
5. Connect the bell wire to the opener terminal screws: white to 2
and white/red to 1.
6. Use tacks or staples to permanently attach the entrapment
warning label to the wall near the door control, and the manual
release/safety reverse test in a prominent location on the
inside of the garage door.
NOTE:
DO NOT connect the power and operate the opener at this
time. The trolley will travel to the full open position but will not
return to the close position until the sensor beam is connected
and properly aligned. See Safety Reversing Sensor instructions
beginning on page 16.
Opener
Terminal Screws
Bell Wire
Antenna
Back Panel
Lighted Door
Control Button
Terminal Screws
Bell Wire
WHT
RED
Kg
1
3
9
7
5
1
3
9
7
5
2
3
1
-2
-1
Lighted
Door Control Button
Kg
HARDWARE SHOWN ACTUAL SIZE