Bullard 88VX Series User Manual - page 5
Operations
8
The requirements for Grade D breathable air include:
Oxygen ...............................................................19.5-23.5%
Hydrocarbons (condensed)
in mg/m3 .................................................... 5 mg/m3 max.
Carbon monoxide ............................................. 10 ppm max.
Carbon dioxide ............................................ 1,000 ppm max.
Odor................................................. Lack of noticeable odor
No toxic contaminants at levels that make air unsafe
to breathe.
Contact the Compressed Gas Association (1725 Jefferson
Davis Hwy, Arlington, VA 22202) for complete details on
Commodity Specification G-7.1.
Air Source
Locate the source of supplied air whether it is an air
compressor or an ambient air pump, such as a Bullard
Free-Air pump, in a clean air environment. Locate the air
source far enough from your work site to ensure the air
remains contaminant-free. Always use an inlet filter on
your air source.
Use suitable after-cooler/dryers, filters, carbon monoxide
monitors and alarms, like the Bullard Clean Air Box (CAB)
Series, as necessary to assure clean, breathable air at
all times.
The air should be regularly sampled to be sure that it
meets Grade D requirements.
Breathing Air Pressure
Air pressure must be continually monitored at the point-
of-attachment while operating this respirator. A reliable
air pressure gauge must be present to permit you to
continually monitor the pressure during actual respirator
operation.
The Breathing Air Pressure Table (page 9) defines the
air pressure ranges necessary to provide 88VX Series
respirators with a volume of air that falls within the
required range of 6-15 cfm or 170-425 lpm (Ref. 42 CFR,
Part 84, Subpart J, Table 8).
Make sure you understand the information in the Breathing
Air Pressure Table before using this respirator.
1. Determine the type of air source you are using (column
1), then find your flow control valve/climate control
device (column 2).
2. Be sure your Bullard air supply hose(s) (column 3) is
approved for use with your flow control valve/climate
control device.
3. Determine that your Bullard air supply hose is within the
approved length (column 4).
4. Make sure you have not exceeded the maximum number
of hose sections (column 5).
5. Set the air pressure at the point-of-attachment within
the required pressure range (column 6) for your flow
control valve/climate control device, and air supply hose
type and length. Accurate pressure readings can only be
attained when air is flowing into the respirator.
NIOSH approved Bullard air supply hose(s) MUST be used
between the breathing tube connection fitting on the
wearer’s belt and the point-of-attachment to the air supply
(Figure 3, Page 10).
NIOSH approved Bullard quick-disconnect fittings MUST
be used to connect V5 or V20 hose lengths together. When
connecting lengths of V10 hose, only use Bullard V11 hose-
to-hose adapters. Secure connection(s) until wrenchtight
and leakfree. Total connected hose length and number
of hoses MUST be within the ranges specified on the
Breathing Air Pressure Table (Page 9) and the respirator’s
NIOSH approval label (Page 3).
The breathing tube connection fitting MUST be secured
to the belt that is supplied with this respirator. Securing
the air entry connection fitting helps prevent the air
supply hose from snagging, disconnecting or pulling the
respirator helmet off your head.
WARNING
Failure to supply the minimum required pressure
at the point-of-attachment for your hose length and
type will reduce airflow and could result in death or
serious injury.
88VX Series Airline Respirator
User Manual
Breathing Air Pressure Table
9
Breathing Air Pressure Table
This table defines the air pressure ranges necessary to provide 88VX Series respirators with a volume of air that falls within the required range of
6-15 cfm or 170-425 lpm according to U.S. Government regulations (42 CFR, Subpart J, 84.150, Table 8).
1
2
3
4
5
6
Flow Control Valve/
Air Supply
Air Supply
Maximum Number
Required Pressure
Air Source
Climate Control Device
Hose
Hose Length (feet)
of Hose Sections
Range (psig air)
Stationary
F30, F30B, F30S, F31, F32,
V10
25
1
14-15
or Portable
F33, F34, F37, F38
50
2
15-18
Air
Compressor
100
3
19-24
150
4
23-29
200
5
25-34
250-300
5
31-39
V5
25
1
12-18
50
2
19-23
F40, F40B, F40S, F41, F42,
V10
25
1
22-25
F43, F44, F47, F48
50
2
24-27
100
3
27-32
150
4
30-37
200
5
33-40
250-300
5
38-45
V5
25
1
22-26
50
2
25-30
AC100030,
AC100030B,
V10
25-50
2
55-65
AC100030S,
AC100031,
75-150
3
60-70
AC100032,
AC100033,
175-300
5
65-75
AC100034,
AC100037,
ACC100038
V5
25
1
55-65
50
1
56-69
DC5040, DC5040B,
V10
50
2
48-52
DC5040S, DC5041,
100
3
59-63
DC5042,
DC5043,
150
3
68-72
DC5044,
DC5047,
200
3
80-84
DC5048
250
3
85-92
300
5
90-98
V5
25
1
53-57
50
2
67-71
HC240030,
HC240030B,
V10
25
1
61-63
HC240030S,
HC240031,
50
2
63-65
HC240032,
HC240033,
100
3
68-70
HC240034,
HC240037,
150
4
73-75
HC240038
200
4
77-79
250
5
80-82
300
5
84-86
V5
25
1
65-66
50
1
68-69
Bullard
F35, F35B, F35S
V20
50
1
4-6
Free-Air
®
100
2
6-8
Pumps
200
2
10-15
300
3
13-18
Frigitron
2000
V20
50
1
16-22
Frigitron
2000B
100
2
18-25
Frigitron
2000S
200
2
22-30
300
3
25-34
S - Special or Critical Users Instructions