Bullard EDP30 User Manual

Manual is about: Free-Air Pumps

Summary of EDP30

  • Page 1

    Free-air® pumps user manual www.Bullard.Com general information bullard free-air pumps transfer ambient air from a clean air location, where breathable air can be assured at all times, to workers wearing type c or ce continuous flow supplied air respirator hoods or tight fitting half- or full-face m...

  • Page 2: Www.Bullard.Com

    Www.Bullard.Com warning 2 w arnings read all instructions in this manual before using free-air ® pump models edp30 or edp50. Failure to operate these pumps in accordance with the instructions contained in this manual may result in death or serious injury to the respirator wearer. 1. Place the pump...

  • Page 3: Www.Bullard.Com

    Www.Bullard.Com free-air® pumps user manual 3 pump p erf ormance t ables number of respirators that can be used with pumps depending on the pump model and style of respirator(s) being used, bullard edp30 and edp50 free-air pumps will supply air for up to ten (10) workers. Refer to the respirator’s m...

  • Page 4: Www.Bullard.Com

    Www.Bullard.Com 4 br eathing air requir ements/a ssembling the air pump breathing air requirements air quality the free-air ® pump’s inlet filters must be located in a clean breath- able air location at all times. Breathable air drawn into the inlet filters must meet at least the requirements for ty...

  • Page 5: Free-Air® Pumps

    Free-air® pumps user manual 5 pump p erf ormance www.Bullard.Com electric motor specifications: edp30 and edp50 enclosure: open, drip-proof class: natl. Elec. Code: class b design l code k h.P. Five phase: single cycles: 60 wiring: 208-230 volts as shipped, with 8 foot cord and three wire, 30 amp pl...

  • Page 6: Www.Bullard.Com

    Www.Bullard.Com operating the free-air® pump 1. Analyze the atmosphere at the location of the worksite, the air inlet and the pump, to be sure the pump will not be operating in a contaminated or an explosive atmosphere. 2. Make sure the pump’s inlet filters are located in a clean, uncontaminated loc...

  • Page 7: Www.Bullard.Com

    Www.Bullard.Com 7 oper ating the fr ee-air pump a) close the dump valve by turning the red knob clockwise until no air can escape (figure 9). Note the dump valve provides a course pressure adjustment and may have to be used if the respirator’s approved pressure is below 10 psig. If so, you will also...

  • Page 8: Www.Bullard.Com

    Www.Bullard.Com 8 maintaining the fr ee-air pump maintaining the free-air® pump bullard edp30 and edp50 free-air pumps consist of an electrically- driven air pump with four carbon vanes. The vanes self-adjust as they wear and should last the following length of time if properly maintained: edp30 - 3...

  • Page 9: Www.Bullard.Com

    Www.Bullard.Com 9 troubleshooting guide if your bullard free-air pump is not working satisfactorily, follow the trouble shooting steps below: symptom: pump fails to start or hums 1. Turn pump switch off and disconnect from the power source. 2. Check for the correct electrical current as shown in the...

  • Page 10: Www.Bullard.Com

    Www.Bullard.Com replacement parts and accessories replacement parts list for both edp30 and edp50 free-air ® pumps cat. No. Description 23611 inlet filter 26701 gasket, pod, filter side 27161 gasket, pod, cover side 28151 pressure relief valve edp30 28152 pressure relief valve edp50 s16481 quick-dis...

  • Page 11: Www.Bullard.Com

    Www.Bullard.Com free-air® pumps user manual 11 pump w arr anty/ return a uthorization return policy edp30 and edp50 model free-air pumps are built to the unique customer specifications at the time of order and therefore are not re- turnable for credit. Please keep this in mind when placing your orde...

  • Page 12: Www.Bullard.Com

    ©2014 bullard. All rights reserved. Free-air is a registered trademark of bullard. 6095000710c (1214) iso 9001 certified www.Bullard.Com americas: bullard 1898 safety way cynthiana, ky 41031-9303 • usa toll-free within usa: 877-bullard (285-5273) tel: +1-859-234-6616 fax: +1-859-234-8987 europe: bul...