Bunn LPG Installation And Operating Manual - page 4
4
ELECTRICAL REQUIREMENTS
The grinder has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp, single
phase, 60 Hz for 120V models; and 100 volts ac, 15 amp single phase, 50Hz for 100V models.
P1028
P1029
OPERATING CONTROLS
Off/On/Start Switch (Models LPG and LPG-2E)
OFF - (upper position) Switching to this position stops all operation of
the grinder.
ON - (middle position) The switch will return to this position after a grind
cycle has begun and will remain in this position after grinding has ceased.
START - (lower, momentary position) Pressing the switch to this position
and releasing initiates a grind cycle.
Hopper Selector Switch (Model LPG-2E only)
LEFT
- Switching to this position allows beans to be ground from the left
hopper.
RIGHT
- Switching to this position allows beans to be ground from the
right hopper.
27091 042211
PREVENTIVE MAINTENANCE
Bunn-O-Matic
®
Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance
should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic
®
Corporation at
1-800-286-6070.
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.
6-Month
Weekly Cleaning plus replace the dechaffer assembly.
1-Year
1. On grinders with slide plates check the slide plates and clean.
2. Inspect and clean/replace burrs and grind chamber if necessary.
3. Adjust the burrs and grind time to your specifications for particulate size and throw weight.