TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Only Water Flowing from Faucet
Head on Beverage Thinner than
Desired
1. Bag-in-Box (BIB) or caddy is
empty.
2. BIB or caddy is not engaged in
bottle adapter properly.
1. System is not set to tempera-
ture yet (ice bank not fully
formed).
2. a) Tank regulator is below 125
psi (red LED Nitrogen “Out”
light is flashing on dispenser
door).
b) Gas leak on tank regulator.
1. Change BIB to full BIB or refill
the caddy with more product.
2. Lift BIB or caddy out of adapt-
er and seat it back down prop-
erly. Follow step-by-step in-
structions on priming product
through the system.
1. Wait until system is fully cooled
and ice bank fully formed
before setting preferred N2
pressure. Check Compressor
switch is set to ON and sight
gauge shows full water bath. If
water bath sight gauge is low,
press Dispense switch to OFF.
Wait a few seconds. Press Dis-
pense switch to ON. Bath will
automatically start filling water
bath after 30 seconds.
2. a) Adjust tank regulator by
turning the T-handle clockwise
until needle reaches 125 psi.
Dispense a drink to make sure
needle stays set at 125 psi.
b) If gas is leaking from tank
regulator, replace tank regula-
tor by contacting manufactur-
er or supplier.