  • Page 1

    Split air conditioner design inverter series (arctic) МОДЕЛИ: owner’s manual ch-s09ftxs-b ch-s12ftxs-b ch-s09ftxs-m ch-s12ftxs-m ch-s09ftxs-w ch-s12ftxs-w designed by cooper&hunter international corporation, oregon, usa www.Cooperandhunter.Com f or proper operation, please read and keep this manual ...

  • Page 2

    Annual energy efficiency perfomance ratio i s calculated by overall capacity and average operaing time (apr 500 hours) multiplication in full-load coling mode operation. Cooling capacity i s device cooling capaciy (demanded in kwh) in full-load cooling mode operation. Err energy label index is ratio...

  • Page 3

    ■ 1 ■ 7 ■ 13 ■ 16 ■ 24 ■ 25 ■ 28 ■ 21 ■ 29 ■ 6 ■ 12 do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Contents operation and maintenance precautions ...........................................................................

  • Page 4: Precautions

    1 precautions warning do not connect air conditioner to multi-purpose socket. This appliance can be used by children aged from 8 operation and maintenance if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a haza...

  • Page 5: Precautions

    Do not block air outlet or air inlet. It may cause malfunction. Remote controller may be broken. ● power cord is overheating or damaged. ● there’s abnormal sound during operation. ● circuit break trips off frequently. ● air conditioner gives off burning smell. ● indoor unit is leaking. Contact the d...

  • Page 6: Precautions

    Do install the circuit break. If not, it may cause malfunction. Of at least 3mm in all poles should be connected in fixed wiring. Magnet buckle and heating buckle function, it can protect the circuit-short and overload. Power supply circuit and circuit break. 3 precautions warning note the following...

  • Page 7: Precautions

    Installation must be performed in accordance with the persons in order to avoid a hazard. Must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The appliance must be positioned so tha...

  • Page 8: Precautions

    The indoor unit should be installed close to the wall. reachable after finishing installation. Far away from animals or plants.If it is unavoidable, please add the fence for safety purpose. 5 precautions warning place, only the qualified person can perform the work. Otherwise, it may cause personal ...

  • Page 9

    ⑹ ⑸ ⑵ ⑻ ⑼ ⑽ ⑷ ⑺ ⑶ ⑴ power cord remote controller front panel filter horizontal louver wall pipe binding tape connection wires drain hose drain connector name of parts ⑸ ⑻ ⑶ ⑼ ⑽ ⑴ ⑵ indoor unit air in air out outdoor unit air in air out ⑷ ⑹ ⑺ : cool : dry : heat : set temp. : power the icons displaye...

  • Page 10

    Operation of remote controller t-on t-off 1 7 press it to set health or air function. 8 i feel / 4 3 2 5 6 11 13 12 16 10 14 9 15 press it to start or stop operation. On/off mode + - press it to select operation mode (auto/cool/dry/fan/heat). : press it to increase temperature setting. : press it to...

  • Page 11

    Operation of remote controller 6 press this button to set up &down swing angle, which circularly changes as below: off this remote controller is universal . If any command , or is sent out, the unit will carry out the command as indicates the guide louver swings as: press this button to turn on i fe...

  • Page 12

    Operation of remote controller remote controller description p ress this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the first time to start scavenging function; lcd displays“ ”. Press the button for the second time to start healthy ...

  • Page 13

    Operation of remote controller light: 15 press light button to turn on the display's light and press this button again to turn off the display's light. If the light is turned on , is displayed. If the light is turned off, disappears. Turbo: 14 press this button to activate / deactivate the turbo fun...

  • Page 14

    Operation of remote controller ★ ● ● ● ● ● 1.Remove the battery cover plate from the rear of the remote controller. (as shown in the figure) 2.Take out the old batteries. 3.Insert two new aaa1.5v dry batteries, and pay attention to the polarity. 4. Reinstall the battery cover plate. When replacing t...

  • Page 15

    Mode model temperature setting airflow rate auto cooling 25 ( cool,fan) auto auto heat ℃ ℃ ℃ pump 25 ( cool,fan) auto auto heat pump 20 ( heat) auto emergency operation when the remote controller is lost or damaged, please use the manual switch on the main unit. In that case, the unit will operate i...

  • Page 16

    ℃ ? ? (fig.A) (fig.B) caution wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleaner (not with volatile liquid such as thinner or gasoline). Note: if the air conditioner operates under dusty environment, the frequency of cleaning air filter shall increase correspon...

  • Page 17

    1. Press the clasp as shown by arrow (1) to loosen the clasps at the lower end until a sound of “crack” is heard; press the clasp as shown by arrow (2) to open the clasps at the upper end; open the panel and then pull the filter downward to remove it. (as shown in fig a) 2. Install the healthy filte...

  • Page 18

    ① make sure that nothing obstructs the air inlet and air outlet of indoor and outdoor units. ② ③ ① ② ③ ④ ④ check before use maintenance after use disconnect the power for the air conditioner. Clean the filter and the body of indoor and outdoor units. Remove the dust and other objects on the outdoor ...

  • Page 19

    ● ● ● ● ● ● troubleshooting caution phenomenon troubleshooting waiting the unit does not operate: the unit does not operate if it is turned on immediately after being turned off. This is to odours are emitted: some odours may be emitted from the indoor unit. This is the result of room smells (such a...

  • Page 20

    ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● troubleshooting phenomenon troubleshooting the unit can not be started up: is the power cut off? Is the power plug loose? ( if ap plicable) is the circuit protection device tripped off? Is voltage higher or lower? (tested by professionals) is the timer corre...

  • Page 21

    In heat mode, when the temperature of indoor heat exchanger is very low, air flow is stopped in order to prevent cold air. (within 2 minutes) in heat mode, when the outdoor temperature is low or humidity is high, frost will be formed on the outdoor heat exchanger. The unit will defrost automatically...

  • Page 22

    Operation tips cooling operation principle: air conditioners absorb heat in the room and transmit it to the outdoor unit so that the room temperature is decreased. The cooling capacity will increase or decrease according to outdoor ambient temperature. Freeze protection: if the unit is operating in ...

  • Page 23

    Operation tips tips for energy saving: * do not overcool or overheat. Setting temperature at a moderate level helps energy saving. * cover windows with a blind or a curtain. Blocking sunlight and air from outdoors is favorable for cooling (heating). * clean air filters once per two weeks. Clogged ai...

  • Page 24

    4.Warning: before obtaining access to terminals, all supply circuits must be disconnected. 5.For appliances with type y attachment, the instructions shall contain the substance of the following. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qu...

  • Page 25

    Note: notices for installation safety precautions for electric appliances installation site of outdoor unit 1.Select a site where noise and outflow air emitted by the unit will not annoy neighbors. Select a site where there is sufficient ventilation. Select a site where there is no obstruction block...

  • Page 26

    Earthing requirements ① ② ③ ④ 1. Air conditioner is type i electric appliance. Please ensure that the unit is reliably earthed. 2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may cause electric shock. 3. The earth resistan...

  • Page 27

    Space to the wall above above installation dimension diagram installation dimension diagram space to the ceiling space to the wall space to the wall air outlet side space to the floor above above above above above space to the obstruction air outlet side space to the wall air inlet side above above ...

  • Page 28

    Ø 55 drill piping hole 1.Slant the piping hole ( 55) on the wall slightly downward to the outdoor side. 2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. Indoor outdoor wall pipe seal pad installation of indoor...

  • Page 29

    09k,12k, yellow- green 3 brown ● ● ● after tightening the screws, pull the wire slightly to confirm whether it's firm or not. ● ● make sure that all wiring connections are secure and the cover plates are reinstalled note: all wires between indoor and outdoor units must be connected by the qualified ...

  • Page 30

    Installation of indoor unit 4. 2. 3. ● 1. ⑴ ⑵ 1. 2. Installation of indoor unit the piping can be output from right, right rear, left or left rear. When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis when necessary(as shown in fig.7) c...

  • Page 31

    Manifold valve multimeter -76cmhg lo handle charging hose manometer hi handle charging hose vacuum pump low pressure valve Ø 、 09 12k 18k n(1) indoor unit connection blue black brown yellow-green 2 3 handle 3. 4. 5. 1. 2. Remove the handle on the right side plate of outdoor unit. Take off wire clamp...

  • Page 32

    1. (1) do not switch on power before installation is finished completely. (2) electric wiring must be connected correctly and securely. (3) cut-off valves of the connection pipes should be opened. (4) 2. (1) switch on power and press "on/off" button on the remote controller to start operation. (2) c...

  • Page 33

    Installation and maintenance of healthy filter(optional) fig. A 1. 2. (as shown in fig.B). 3. Install the air filter properly along the arrow direction in fig.C, and then close the panel . Cleaning and maintenance service life ● filter air filter (as shown in fig.A) fig. B fig. C lift up the front p...

  • Page 34

    1. Standard length of connection pipe 5m、7.5m、8m 2. Min length of connection pipe for the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m. 3. Max...

  • Page 35

    Sheet 2. Additional refrigerant charging amount for r22 r407c r410a and r134a note: the additional refrigerant charging amount in sheet 2 is recommended value, not compulsory. Diameter of connection pipe mm indoor unit throttle outdoor unit throttle liquid pipe gas pipe cooling only, cooling and hea...

  • Page 36

    Designed by cooper&hunter international corporation, oregon, usa www.Cooperandhunter.Com e-mail: info@cooperandhunter.Com.