C&H Technologies M 2 2 0 User Manual

Summary of M 2 2 0

  • Page 1

    M o d e l m 2 2 0 ( f o r m e r l y h p e 2 2 7 2 a ) u s e r ’ s m a n u a l d u a l 8 x 1 m u l t i p l e x e r m - m o d u l e document part no: 11029554 c&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 2

    Ii copyright c&h technologies, inc. (c&h) provides this manual "as is" without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. C&h may make improvements and/or changes in the product(s) an...

  • Page 3

    Iii amendment notice c&h technologies, inc. Makes every attempt to provide up-to-date manuals with the associated equipment. Occasionally, changes are made to the equipment wherein it is necessary to provide amendments to the manual. If any amendments are provided for this manual they are printed on...

  • Page 4

    Iv introduction this manual describes the operation and use of the c&h model m220 dual 8x1 multiplexer m- module (part number 11029550). This module was formerly manufactured by hp (agilent) as model e2272a. C&h obtained the manufacturing rights from agilent and now manufacturers it as c&h model m22...

  • Page 5

    V table of contents 1.0 general description................................................................................................ 1 1.1 purpose of equipment ................................................................................... 1 1.2 specifications of equipment...................

  • Page 6

    Vi list of figures figure 1. M-module installation ............................................................................................ 5 figure 2. M220 functional block diagram................................................................................. 7 figure 3. M220 switching schema...

  • Page 7

    1 1.0 general description the m220 provides two separate 8 to 1, two-wire multiplexers or you can move a jumper to connect the common channels of each multiplexer together and create a single 16 to 1, two-wire multiplexer on a single wide m-module adhering to the ansi/vita 12-1996 specification for ...

  • Page 8

    2 1.2.2 specifications the m220 incorporates the standard 40-pin, 20x2 row connector interfaces to the carrier board for power and data/control, but does not have the 24-pin optional connector for carrying user- connections back onto the carrier board. The user input/output is provided through a sta...

  • Page 9

    3 1.2.3 mechanical the mechanical dimensions of the module are in conformance with ansi/vita 12-1996 for single-wide m-module modules. The nominal dimensions are 5.687” (144.5 mm) long 2.082” (52.9 mm) wide. 1.2.4 bus compliance the module complies with the ansi/vita 12-1996 specification for single...

  • Page 10

    4 c&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 11

    5 2.0 installation 2.1 unpacking and inspection verify that there has been no damage to the shipping container. If damage exists then the container should be retained, as it will provide evidence of carrier caused problems. Such problems should be reported to the shipping courier immediately, as wel...

  • Page 12

    6 2.4 preparation for reshipment if the module is to be shipped separately it should be enclosed in a suitable water and vapor proof anti-static bag. Heat seal or tape the bag to insure a moisture-proof closure. When sealing the bag, keep trapped air volume to a minimum. The shipping container shoul...

  • Page 13

    7 3.0 functional description 3.1 overview a simplified functional block diagram is shown in figure 2. A(7:1) d(15:0) carrier interface /iack /cs /ds0 /write gnd +5v +12v /dack /dreq col(4:1) reset & power supply conditioning row _set(4:1) dr_en vcc zgnd vcc +5vdr row _reset(4:1) /reset sysclk /ds1 /...

  • Page 14

    8 3.1.3 id eeprom the eeprom holds sixty-four 16-bit words of m-module id data and vxi m-module data. Refer section 3.2.3 for more details. 3.1.4 row and column drivers the module uses a matrix drive scheme (rows and columns) in which a maximum of four of the relays (one row) can be operated at any ...

  • Page 15

    9 1 ch0_hi 2 ch0_lo 18 ch1_hi 33 ch1_lo 17 ch2_hi 32 ch2_lo 16 ch3_hi 31 ch3_lo 22 ch4_hi 6 ch4_lo 21 ch5_hi 5 ch5_lo 20 ch6_hi 4 ch6_lo 19 ch7_hi 3 ch7_lo 34 - 41 25 ch8_hi 9 ch8_lo 26 ch9_hi 10 ch9_lo 27 ch10_hi 11 ch10_lo 28 ch11_hi 12 ch11_lo 13 ch12_hi 29 ch12_lo 15 ch13_hi 14 ch13_lo 30 ch14_h...

  • Page 16

    10 3.2 identification and configuration registers 3.2.1 setting multiplexer size figure 4 shows the two jumper positions for the m220. When in position a (jumper not connecting one row of pins), the module is configured as a dual 8-to-1 multiplexer. When in position b (jumper connecting all pins), t...

  • Page 17

    11 3.2.2 i/o registers there are a variety of registers used to configure and control the m219 module. These registers are located in the iospace. The address map of the registers is shown in table ii. Details of the registers are provided in figure 5. Table ii. I/o address map/command summary regis...

  • Page 18

    12 reg. 00 status bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 write read-only read reserved init mps fifoe fifof int init  init status (1 = initialized since last power up, 0 = not initialized since last power up) mps  multiplexer size (0 = 16 to 1 multiplexer, 1 = dual 8 to 1 multiplexer, see note)...

  • Page 19

    13 reg. 10 row 0 set register bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 write unused r0c3 r0c2 r0c1 r0c0 read unused r0c3 r0c2 r0c1 r0c0 reg. 12 row 0 reset register bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 write unused r0c3 r0c2 r0c1 r0c0 read unused r0c3 r0c2 r0c1 r0c0 reg. 14 row 1 set register ...

  • Page 20

    14 3.2.3 module identification the m220 supports the identification function called ident. This ident function provides information about the module and is stored in a sixteen-word deep (32 byte) serial prom. Access is accomplished with read/write operations on the last address in iospace (hex fe) a...

  • Page 21

    15 4.0 operation the m220 is a register-based instrument that is controlled through a series of i/o registers described in section 3.2.2. The exact method of accessing and addressing the i/o registers is dependent on the m-module carrier used to interface the module to your data acquisition or test ...

  • Page 22

    16 3. The row n set/reset readback registers return the programmed relay state only if you use the module correctly. Since the driver power can be disabled (the power-on state), the row n set and row n reset registers can be written to and read from without moving any relay contacts. 4. When the mod...

  • Page 23

    17 if the m-module is enabled to interrupt, it asserts the int line on the m-module interface to the carrier when the last commanded relay operation in the fifo has completed. For example, if relays in only one row were instructed to move, the module asserts an interrupt after that one row has been ...

  • Page 24

    18 c&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 25

    A-1 appendix a: connectors maximum voltage/current. The maximum voltage that may be applied to any connector on the m220 is 200 vdc, 125 vac rms, or 175 vac peak--these limits apply only if the product is installed in a humidity-controlled ( transients are controlled, and there is not a relay connec...

  • Page 26

    A-2 c&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 27

    N o t e s: c&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 28

    . C&h technologies, inc. 445 round rock west drive round rock, texas 78681 www.Chtech.Com.

  • Page 29

    Reader's comment form your comments assist us in improving the usefulness of c&h's publications; they are an important part of the inputs used for revision. C&h technologies, inc. May use and distribute any of the information that you supply in any way that it believes to be appropriate without incu...

  • Page 30

    Instructions in its continuing effort to improve documentation, c&h technologies, inc. Provides this form for use in submitting any comments or suggestions that the user may have. This form may be detached, folded along the lines indicated, taped along the loose edge (do not staple), and mailed. Ple...