    Part number 5-051-503-00 rev a 1 2 5 4 7 8 3 6 9 0 # panic p a g e.

  • Page 2

    2 thank you for purchasing this c&k alarm system. Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide you with years of reliable operation. This manual explains how to operate your alarm system. Basic operating instructions are also printed on ...

  • Page 3

    3 table of contents getting acquainted ............................................... 4 - 5 what the lights mean ........................................... 6 - 7 what the sounds mean ........................................ 8 - 9 arming the system ............................................ 10 - ...

  • Page 4

    4 what your alarm system is... Your alarm system is made up of a control panel and several detection devices like motion sensors, magnetic contacts, and so on. Specific areas of detection are called zones. Zones can be programmed to have different characteristics. Some zones may be 24-hour zones, th...

  • Page 5

    5 each alarm system in the 2300 family is designed to meet the specific needs of a variety of applications. The system 236e is designed for applications requiring protection of six zones. Some of the available features of your alarm system are also optional, and will only be installed if appropriate...

  • Page 6

    6 on off flashing ac power is being supplied battery is low; call your service department ac power failure - system is using battery . . . System is armed - protection is on system is not armed - protection is off system is armed with delay zones converted to instant zones . . . Power arm normal sta...

  • Page 7

    7 on off flashing bell fuse failed . Flashing slow - watchdog reset normal state . . . Service power, arm, and service flashing slow - flashing fast - failed to communicate . . The power, arm, and service lights simultane- ously flash (slowly) when in the programming mode. Zone is in trouble (when a...

  • Page 8

    8 sound meaning 2 beeps (confirmation tones) system armed or disarmed . Successful central station test or battery test . Pulsed tone (2 seconds on, 2 seconds off) zone programmed for pulsed bell or siren is in alarm . Continuous tone zone programmed for steady bell or siren is in alarm circuit malf...

  • Page 9

    9 sound meaning 3 pulse temporal pattern (½ second on / ½ second off / ½ second on / ½ second off / ½ second on / 1½ second off - repeating) * zone programmed for 3 pulse temporal pattern is in alarm (this is the audible signal which ul has designated for fire-protection zones.) . . Trouble chirp (2...

  • Page 10

    10 make sure all the zone lights are off. Faulted zones must be cleared or bypassed before the system can be armed. For more information, refer to the sections bypassing zones and after an alarm occurs. To arm the system / auto home arming: . If programmed, the red zone lights will automatically tur...

  • Page 11

    11 exit through any time delay door within seconds. The exit delay time can be programmed from 10 seconds to 150 seconds. . . Once the exit delay time has expired, the keypad will beep twice to confirm that the system is armed. If the exit pre-alarm option is installed, the keypad will beep slowly u...

  • Page 12

    12 instant arming instant arming converts all time delayed zones to instant zones. Make sure all the zone lights are off. Pin required . . Option installed exit delay disable (see page 17). . Home arming or bypassing interior zones will allow you to move about freely inside the premises while the sy...

  • Page 13

    13 enter your pin (if required), push the key, enter the digit "4", then push the # key. The keypad will beep twice to confirm that the system is armed. Home arming arms perimeter zones, while bypassing interior zones. Home arming make sure all the zone lights are off. The red arm light will be on w...

  • Page 14

    14 instant home arming instant home arming arms the perimeter zones and bypasses interior zones. Entry time delays are converted to instant. Make sure all the zone lights are off. The keypad will beep twice to confirm that the system is armed. Enter your pin (if required), push the key, enter the di...

  • Page 15

    15 bypassing zones this procedure allows you to bypass one or more zones while your system is disarmed*. Note: system programming determines which zones can be bypassed. To learn if a zone can be bypassed, see the zone description list on page 38. Enter your pin (if required). Pin required push the ...

  • Page 16

    16 note: disarming your alarm system removes all bypasses (except for 24-hour zones). . The procedures for adding a bypass and removing a bypass are identical. To remove a bypass: enter your pin, push the key, enter the digit "2", enter the zone from which the bypass is to be removed, then push the ...

  • Page 17

    17 your alarm system has been programmed for one of the following two arming types: goof-proof arming if any zone other than a 24-hour zone is faulted (open window, malfunction- ing sensor, etc.), your system will not arm. You will not be able to arm the system until the faulted zone is cleared or m...

  • Page 18

    18 to disarm the system: enter only through a time delay door. If the entry pre-alarm option is installed, the keypad will sound constantly until 10 seconds before the delay time expires (or the panel is disarmed), then beep rapidly for the last 10 seconds. . Option installed enter your pin within s...

  • Page 19

    19 after an alarm occurs: enter your pin and push the # key. This will silence the bell/siren and disarm the system. . The red zone lights on the keypad will flash fast to help you remember where the violations occurred. . Pin required if this is a false alarm and no emergency response is needed, ca...

  • Page 20

    20 24-hour monitoring with this option installed, your alarm system will transmit alarm signals to our central station. Option installed police/panic keys when this option is installed, holding down the "7" and "9" (panic) keys at the same time will trigger an alarm. The keypad will beep twice to co...

  • Page 21

    21 pager open/close reports (system 236e or later only) if the pager open/close reporting option is enabled, arming or disarming your system will initiate a special report to your paging device. This will be a 2-digit code, using the following format: digit 1: user number arming or disarming the sys...

  • Page 22

    22 user 1 can use his master pin to change the pins of users 1 - 6. Changing a system 236e user pin enter your master pin, push the key, enter the digit "0", then push the # key. 0 master pin required the power, service, and arm lights will slowly flash. . Enter the user number (1 - 6), and push the...

  • Page 23

    23 enter the new pin again and push the # key. If the new pin is accepted, the keypad will beep twice. If you make a mistake while programming, or if the system rejects the new pin, the keypad will beep five times. Try again. . If no key is pressed for 5 minutes, the system will automatically exit t...

  • Page 24

    24 resetting smoke detectors when a smoke detector is triggered, the red zone light of the zone where it's located will come on, and the bell/siren will sound. Option installed before you do anything else, evacuate the building. Don't go back inside until your sure it's safe. When it's safe to do so...

  • Page 25

    25 door chime when this option is installed, the keypad will beep for two seconds each time a designated zone is faulted. Option installed to turn the door chime on and off (for all keypads installed): push the key, enter the digit "5", then push the # key. 5 keypad tone disable you can disable the ...

  • Page 26

    26 keypad tone disable (continued) to turn the entry/exit pre-alarm tones (entry/exit delay countdown) on and off: push the key, enter the digit "5", the digit "2", and push the # key. 2 5 to turn the confirmation/error tones on and off: push the key, enter the digit "5", the digit "4", and push the...

  • Page 27

    27 local system test this option allows on-site testing of each zone in your system. To initiate the system test: enter your pin (if required), push the key, enter the digit "6", the digit "0", then push the # key. Once the keypad lights go out, the system will be ready for testing. Walk through the...

  • Page 28

    28 to manually test the standby battery, push the key, enter the digit "6", the digit "4", then push the # key. Standby battery test your alarm system can be programmed to automatically test its standby battery every 4 hours. During the test, ac power is turned off in order to monitor the battery un...

  • Page 29

    29 if you have telephone trouble: first, unplug the control panel from its telephone jack to determine if the alarm system is causing the trouble. The phone jack is located . If the trouble goes away when you unplug the control, call us for service. If you still have telephone trouble after unpluggi...

  • Page 30

    30 we subscribe to the recommendations for the number and placement of smoke and/or heat detectors found in the national fire protection association's standard #72, chapter 2 (n.F.P.A. Batterymarch park, quincy, ma 02269). For the best early warning, fire detection devices should be installed in all...

  • Page 31

    31 every household should establish and regularly practice an escape plan in the event of a fire. The following steps, recommended by the national fire protection association, can be used as a guide in developing your own emergency plan. Establish a meeting place outdoors, away from the house, where...

  • Page 32

    32 alarm a condition that occurs when the detection devices in a zone are triggered after the system is armed. Alarm memory alarm conditions are stored in memory until cleared. Exit delay once the system is armed, the time you have to exit the premises through a delay door (before an alarm occurs). ...

  • Page 33

    33 the limitations of your alarm system while your alarm system is reliable and sophisticated, it does not offer guaranteed protection against burglary or fire. Any alarm system, whether commercial or residential, is subject to compromise or failure-to-warn for a variety of reasons. These include: i...

  • Page 34

    34 for your convenience, the following is a list of the keypad operations discussed in these instructions. Keys functions personal idendification number (pin) arms and disarms the system 0 programs new user pins (master pin required). 1 clears the alarm memory bypasses individual zones (pin may be r...

  • Page 35

    35 keys functions 2 5 turns the entry/exit pre-alarm tones on/off. 4 5 turns the error tones on/off. 6 0 initiates the local system test (pin may be required). 1 5 turns the audible keypad feedback on/off. 2 6 resets smoke detectors. 3 6 initiates the bell/siren test (pin may be required). 3 5 turns...

  • Page 36

    36 keys functions 4 6 initiates the standby battery test. 7 converts all time delay zones to instant and arms the system (pin may be required). 4 7 converts entry time delay zones to instant (if programmed to do so), and arms perimeter zones, while bypassing interior zones (pin may be required). Ref...

  • Page 37

    37 as required by ul standard 1023, your alarm system is a grade "a" system (see definition on page 32). Alarm system malfunctions and failures are caused most often by inadequate maintenance. Your alarm system should be tested weekly to make sure that all detection devices are working properly. In ...

  • Page 38

    38 zone location yes no bypass 1 2 3 4 5 6.

  • Page 39

    39 fcc notice warning: this device is intended to be installed by a professional alarm installer. The user shall be cautioned that changes or modifications not expressly approved by c&k systems could void the user’s authority to operate the equipment. Fcc rules part 15 this equipment has been tested...

  • Page 40

    40 industry canada notice: the canadian department of communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. Industry canada does not guarantee the equipment will opera...