5.3 SETTING THE TIMER
The Timer duration is set by configuring the
Timer Range
and
Timer Settings
switches.
• The Timer Range is determined by the positions of the Timer Range switches R1 and R2.
• The Timer Settings is determined by the sum of the values for each of the Timer Settings switches that are set
to ON (any combination of 8, 4, 2 and 1)
TIMER RANGE
TIMER SETTINGS (8, 4, 2 and 1)
R1
R2
MULTIPLIER
MIN TIME SETTING
MAX TIME SETTING
OFF
OFF
10 seconds
10 seconds
2.5 minutes
ON
OFF
1 minute
1 minute
15 minutes
OFF
ON
10 minutes
10 minutes
2.5 hours
ON
ON
1 hour
1 hour
15 hour
The Timer duration is then calculated by the Timer Settings multiplied by the Timer Range.
For example, if 8,2 and 1 are ON, and the range R1 is OFF and R2 is ON, the timer duration will be
(8 + 2 + 1) x 10 minutes = 110 minutes ( 1 hour and 50 minutes )
5.4 APPLICATION EXAMPLE 1
10 minute timer, Power ON when timer is running, Indicator ON while power ON
• Set all switches to the OFF position
• Set the Load Output switch to the NO position to select the power ON during timer mode.
• Set the LED Indicator switch to the ON position to select the indicator on while power ON mode.
• Set the Timer Range to 1 minute ( 1 minute to 15 minutes possible duration ) switch R1 = ON, switch R2 = OFF
• Set the Timer Settings switches to add up to 10 ( 8 + 2 = 10 ), 10 x 1 minute = 10 minutes
LOAD
OUTPUT
IND
LED
TIMER
RANGE
TIMER
SETTINGS
NO
ON
R1
R2
8
4
2
1
NC
OFF
OFF
OFF
OFF
OFF
OFF
OFF
5.5 APPLICATION EXAMPLE 2
7 hour timer, Power OFF when timer is running, Indicator ON while power OFF
• Set all switches to the OFF position
• Set the Load Output switch to the NC position to select the power OFF during timer mode.
• Set the LED Indicator switch to the OFF position to select the indicator OFF while power ON mode.
• Set the Timer Range to 1 hour with switch R1 = ON, switch R2 = ON
• Set the Timer Settings switches to add up to 7 ( 4 + 2 +1 = 7 ), 7 x 1 hour = 7 hours.
LOAD
OUTPUT
IND
LED
TIMER
RANGE
TIMER
SETTINGS
NO
ON
R1
R2
8
4
2
1
NC
OFF
OFF
OFF
OFF
OFF
OFF
OFF