Cablematic WL2001 User Manual - page 5
Well SEC Electronic Co.,Ltd
www.wellsecurityalarm.com
Ver 1.1
- 5 -
Symptoms Causes Remedies
Cannot alarm by phone
1.
Hasn’t armed
2.
Less than 30 seconds after arming.
3.
Set wrong phone num
4.
The two parts of door\window
sensor is installed too far from
each other.
5.
Haven’t activated PIR.
6.
Hasn’t checked code
1.
Make arming
2.
Operate after 30 seconds
3.
Set the num again according to
the manual
4.
Adjust the installation place of
the door sensor
5.
Activate the PIR
6. Check code again
Remote controlling distance is too
short and the light indicator is not on
strong enough
1.
The battery of remote controller
2. Low battery
1.
Clean the rust
2. Change battery
Light indicator of door sensor and
PIR is always on.
Low battery
Change battery
Dial alarm num slowly
The main panel has stored others num
Set it again according to the
operation manual
The main panel cannot receive
accessories signals
Hasn’t checked code
1.
Check the code again
Notice:
■Don’t install the system beside the strongly disturbing equipments like motor, computer etc.
■Should be installed in a concealed place.
■Should be plug firmly and ensure well dissipation
■Only designed for indoor