Cabletron Systems 9A426-01 Appendix

Other manuals for 9A426-01: User Manual
Manual is about: ATM Access Modules

Summary of 9A426-01

  • Page 1

    9031919-02 smartswitch 9000 9a426-01/9a426-02 local management appendix.

  • Page 3: Appendix

    1 appendix 9a426-01/9a426-02 module specific information introduction this appendix contains local management information that is specific to the following atm modules: • 9a426-01 (1 active front panel port; 1 stand-by front panel port) • 9a426-02 (2 active front panel ports) local management screen...

  • Page 4: Module Interfaces

    9a426-01/9a426-02 module specific information 2 module interfaces the 9a426-01 atm module has seven interfaces. Table 1 lists the identifying number, name, and description of each interface. The 9a426-02 atm module has eight interfaces. Table 2 lists the identifying number, name, and description of ...

  • Page 5

    3 9a426-01/9a426-02 module specific information modifying fields and user privileges to modify fields on these modules, you must have read-write or super-user privileges. If you have read-only privileges, you can view information; however, you cannot modify any fields. Virtual channels and virtual p...

  • Page 6

    9a426-01/9a426-02 module specific information 4 fnb resource configuration screen the 9a426-01/9a426-02 fnb resource configuration screen (figure 1), lists all possible connections a module can support on the fnb, displays the current connection, and allows you to change the connection. Figure 1. 9a...

  • Page 7

    5 9a426-01/9a426-02 module specific information fnb resource configuration screen fields the following information briefly explains each fnb resource configuration screen field. Current fddi con: displays the current connections of the selected module to the smartswitch 9000 fnb. Config id displays ...

  • Page 8: Connection Table  Screen

    9a426-01/9a426-02 module specific information 6 connection table screen the 9a426-01/9a426-02 connection table screen (figure 2), displays the currently configured connections on the module. Figure 2. 9a426-01/9a426-02 connection table screen smartswitch 9000 local management 9a426-02 connection tab...

  • Page 9

    7 9a426-01/9a426-02 module specific information connection table screen fields the following information briefly explains each connection table screen field. Atm port current connections number of virtual circuits that are currently open for this port. Elan: name of the elan to which this client is ...

  • Page 10

    9a426-01/9a426-02 module specific information 8 • llc encapsulation logical link control for bridged protocols. You can choose this encapsulation type for pvcs. You cannot use this encapsulation type for svcs. Llc encapsulation inserts an llc snap header for each legacy lan network type that is bein...

  • Page 11: Add/delete Entry Screen

    9 9a426-01/9a426-02 module specific information add/delete entry screen the 9a426-01/9a426-02 add/delete entry screen (figure 3), is used to add or delete a pvc on the module. Figure 3. 9a426-01/9a426-02 add/delete entry screen smartswitch 9000 local management 9a426-02 add/delete entry module name:...

  • Page 12

    9a426-01/9a426-02 module specific information 10 add/delete entry screen fields the following information briefly explains each add/delete entry screen field. Vpi displays the virtual path identifier number of the connection you want to add or delete. Vci displays the virtual channel identifier numb...

  • Page 13

    11 9a426-01/9a426-02 module specific information adding pvcs to the connection table to add a pvc to the connection table: 1. Go to the add/delete entry screen. 2. Use the arrow keys to move the cursor to the vpi field. 3. Enter the number of the vpi you want to add, then press the tab key. 4. Enter...

  • Page 14: Lec Administration Screen

    9a426-01/9a426-02 module specific information 12 lec administration screen the 9a426-01/9a426-02 lec administration screen (figure 4), is used to add, delete, modify, or view lan emulation attributes on the module. Figure 4. 9a426-01/9a426-02 lec administration screen smartswitch 9000 local manageme...

  • Page 15

    13 9a426-01/9a426-02 module specific information lec administration screen fields the following information briefly explains each lec administration screen field. Configure lec (toggle) specifies whether the lan emulation client should auto-configure the next time it is started. Use the space bar to...

  • Page 16

    9a426-01/9a426-02 module specific information 14 if there are currently no active elans, then all choices on the atm specific configuration screen will result in the message “no active elan present”. You can only access the connection table screen and the lec administration screen. You cannot access...

  • Page 17

    15 9a426-01/9a426-02 module specific information 3. Type the name of the elan you want to add. 4. Use the arrow keys to move to the configure lec, max mtu size, and lan type fields. Select the appropriate choice for each field. 5. Use the arrow keys to highlight save, then press the return key. The ...

  • Page 18: Lec Properties Screen

    9a426-01/9a426-02 module specific information 16 lec properties screen the 9a426-01/9a426-02 lec properties screen (figure 5), displays information about the various lan emulation components. Figure 5. 9a426-01/9a426-02 lec properties screen smartswitch 9000 local management 9a426-02 lec properties ...

  • Page 19

    17 9a426-01/9a426-02 module specific information lec properties screen fields the following information briefly explains each lec properties screen field. Lecs atm address displays the atm address of the lecs (if it is known), or the empty string. Lecs configuration direct vpi/vci a bi-directional, ...

  • Page 20: Svc Signalling Screen

    9a426-01/9a426-02 module specific information 18 svc signalling screen the 9a426-01/9a426-02 svc signalling screen (figure 6), is used to change the type of svc signalling and lan emulation used by the module. Figure 6. 9a426-01/9a426-02 svc signalling screen smartswitch 9000 local management 9a426-...

  • Page 21

    19 9a426-01/9a426-02 module specific information svc signalling screen fields the following information briefly explains each svc signalling screen field. Signalling/lan emulation type (toggle) displays the types of signalling and lan emulation to be used by the module. Use the space bar to select o...

  • Page 22: Diagnostics Screen

    9a426-01/9a426-02 module specific information 20 diagnostics screen the 9a426-01/9a426-02 diagnostics screen (figure 7), is used to enable or disable extended diagnostics for the module. Figure 7. 9a426-01/9a426-02 diagnostics screen smartswitch 9000 local management 9a426-02 diagnostics module name...

  • Page 23

    21 9a426-01/9a426-02 module specific information diagnostics screen field the following information briefly explains the diagnostics screen field. Extended diagnostics (toggle) enables or disables extended diagnostics for the atm module. Use the space bar to select one of the following choices: • en...

  • Page 24

    9a426-01/9a426-02 module specific information 22.