    9031993-02 smartswitch 9000-6 slot 9 c106 and 9c706 chassis setup and installation guide.

  • Page 3: Notice

    I notice cabletron systems reserves the right to make changes in speciÞcations and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, Þrmware, or software desc...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5

    Iii notice declaration of conformity application of council directive(s): 89/336/eec 73/23/eec manufacturerÕs name: cabletron systems, inc. ManufacturerÕs address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: cabletron...

  • Page 6

    Notice iv.

  • Page 7: Contents

    V contents chapter 1 introduction smartswitch 9000-6 slot 9c106 overview ................................................................ 1-1 9c106 chassis ......................................................................................................... 1-1 features ............................

  • Page 8

    Contents vi appendix a smartswitch 9000-6 slot chassis security bars installing the security bars .........................................................................................A-1 removing security bars .........................................................................................

  • Page 9: Chapter 1

    1-1 chapter 1 introduction welcome to the cabletron systems smartswitch 9000-6 slot 9c106 and 9c706 chassis setup and installation guide . This manual provides installation instructions and essential reference information for the cabletron systems smartswitch 9000-6 slot networking chassis and its a...

  • Page 10

    Introduction 1-2 the backplane the 9c106 smartswitch 9000-6 slot chassis provides six distinct backplane buses, and the 9c706 provides an additional seventh bus, the cell transfer matrix. Each bus serves a particular set of needs. The seven backplane buses are shown in figure 1-1. Figure 1-1. The sm...

  • Page 11

    1-3 introduction system management bus 10 the system management bus 10, or smb-10, performs similar functions to those of the smb-1 previously discussed in this section. The smb-10 bus is devoted to the transfer of management data within the chassis, but is used for out-of-band or local management o...

  • Page 12

    Introduction 1-4 support for all smartswitch 9000 interface modules the chassis is designed to offer the same networking capabilities as cabletron systems original smartswitch 9000 chassis, thus supporting the same smartswitch 9000 networking interface modules. 9c206-1 power supply the 9c206-1 power...

  • Page 13

    1-5 introduction features thermal overload protection a thermal shutdown circuit is included within the 9c206-1 power supply. This circuit protects the power supply from overheating if a thermal overload occurs. Automatic recovery takes place after the thermal overload condition is corrected. Load s...

  • Page 14

    Introduction 1-6 figure 1-3. The 9c306 system monitor status c o m 1 c o m 2 epim lnk epim-t sm 9c306.

  • Page 15: How to Use This Manual

    1-7 introduction features out-of-band management out-of-band management refers to managing the smartswitch 9000-6 slot via a local management (lm) connection or an snmp-based management application that does not use the same network connection to the chassis as Òuser data.Ó three out-of-band managem...

  • Page 16: Related Manuals

    Introduction 1-8 chapter 1, introduction , provides an overview of the 9c106 and 9c706 chassis, provides a list of related documentation., and details the procedures to follow for obtaining assistance from cabletron systems. Chapter 2, smartswitch 9000-6 slot chassis installation , details the proce...

  • Page 17: Getting Help

    1-9 introduction getting help for additional support related to this device or document, contact cabletron systems using one of the following methods: before calling cabletron systems, have the following information ready: ¥ your cabletron systems service contract number ¥ a description of the failu...

  • Page 18

    Introduction 1-10

  • Page 19: Chapter 2

    2-1 chapter 2 smartswitch 9000-6 slot chassis installation this chapter provides guidelines for choosing a site to install the smartswitch 9000-6 slot chassis. It also provides instructions on unpacking and rack mounting the chassis. Installation instructions for the power supplies, fan tray, system...

  • Page 20: Chassis

    Smartswitch 9000-6 slot chassis installation 2-2 ¥ a standard 3-prong power receptacle must be located within 6 feet of the system. One circuit is recommended for each power supply. The ac wiring for the receptacle must be able to supply 12 amps at 120 volts or 6 amps at 220 volts. Proper grounding ...

  • Page 21

    2-3 smartswitch 9000-6 slot chassis installation rack mounting the smartswitch 9000-6 slot chassis the chassis can be mounted in a standard 19-inch equipment rack. Two people may be required to lift the chassis into place. The chassis is secured with ten bolts, Þve on each side. Using the bolts prov...

  • Page 22

    Smartswitch 9000-6 slot chassis installation 2-4 figure 2-1. Rack mounting the chassis fan 9c406.

  • Page 23: Installing A Power Supply

    2-5 smartswitch 9000-6 slot chassis installation installing a power supply at least one power supply must be installed on the front of the smartswitch 9000- 6 slot chassis. An additional power supply can be added to achieve redundancy. A power supply is installed by plugging it into either the left ...

  • Page 24

    Smartswitch 9000-6 slot chassis installation 2-6 c. Firmly plug the power supply into the corresponding connector on the back of the chassis by pushing the power supply until its frame touches the surface of the smartswitch 9000-6 slot chassis. D. Do not force the power supply in place. If significa...

  • Page 25

    2-7 smartswitch 9000-6 slot chassis installation installing the 9c306 system monitor the 9c306 system monitor is installed in the slot marked sm on the right front side of the smartswitch 9000-6 slot chassis, as shown in figure 2-3. Install a system monitor by following the steps below: the esd (ele...

  • Page 26: Installing A Fan Module

    Smartswitch 9000-6 slot chassis installation 2-8 figure 2-3. Installing smartswitch 9000-6 slot modules installing a fan module the fan module can only be installed in the slot at the top of the chassis, as shown in figure 2-4. Install the fan module by following the steps below: 1. Unpack the fan m...

  • Page 27

    2-9 smartswitch 9000-6 slot chassis installation 2. Remove the fan module from the protective plastic bag. (save the bag in the event the unit must be reshipped.) observe all precautions to prevent damage from electrostatic discharge (esd). 3. Examine the fan module, carefully checking for damage. I...

  • Page 28

    Smartswitch 9000-6 slot chassis installation 2-10 installing smartswitch 9000-6 slot interface modules smartswitch 9000 interface modules can be installed in any of the six slots that are available. To install interface modules, see figure 2-3 and follow the steps below: 1. Remove the blank plate, c...

  • Page 29: Chassis

    2-11 smartswitch 9000-6 slot chassis installation powering up the smartswitch 9000-6 slot chassis power up the smartswitch 9000-6 slot chassis by following the steps below: 1. Plug one end of the power cord (supplied with the power supply) into the ac power socket on the lower right front corner of ...

  • Page 30

    Smartswitch 9000-6 slot chassis installation 2-12.

  • Page 31: Chapter 3

    3-1 chapter 3 9c206-1 power supply operation this chapter describes the operation of the smartswitch 9000-6 slot chassis power supply. The chapter also details the use of lanview leds for troubleshooting and status information. The 9c206-1 power supply can operate with input voltages ranging from 10...

  • Page 32

    9c206-1 power supply operation 3-2 figure 3-1. 9c206-1 power supply lanview leds pwr status led the pwr status led indicates the input and output status of a power supply. The possible states and descriptions of the pwr status led are listed in table 3-1. Table 3-1. Pwr status led led color state de...

  • Page 33

    3-3 9c206-1 power supply operation power supply level indicator led the power supply level indicator led indicates the percentage of the power supply load. The possible states and descriptions of the power supply level indicator led are listed in table 3-2. Power redundancy led the power redundancy ...

  • Page 34

    9c206-1 power supply operation 3-4.

  • Page 35: Chapter 4

    4-1 chapter 4 specifications environment operating temperature: 5¡c to 40¡c (41¡f to 104¡f) storage temperature: -30¡c to 73¡c (-22¡f to 164¡f) operating relative humidity: 5% to 90% (non-condensing) regulatory compliance safety: ul 1950, csa c22.2 no. 950, en 60950, 73/23/eec, and iec 950 electroma...

  • Page 36: 9C206-1 Power Supply

    Specifications 4-2 9c706 smartswitch 9000-6 slot chassis dimensions 66 h x 43.2 w x 40.6 d centimeters (26 h x 17 w x 16 d inches) weight unit: 11.36 kilograms (25 pounds) shipping: 16.82 kilograms (37 pounds) 9c206-1 power supply dimensions 48.3 h x 10.7 w x 36.8 d centimeters (19 h x 4.2 w x 14.5 ...

  • Page 37: Appendix A

    A-1 appendix a smartswitch 9000-6 slot chassis security bars the smartswitch 9000-6 slot chassis is equipped with two security bars that prevent the unauthorized removal of the interface modules. This appendix provides instructions to install the smartswitch 9000-6 slot security bars. To install the...

  • Page 38

    Smartswitch 9000-6 slot chassis security bars a-2 4. To install the top security bar, orient the bar with the securing tabs facing up and toward the chassis. 5. Slide the security bar up, so that the holes of the securing tabs are aligned with the join in the beveled corners of the interface modules...

  • Page 39: Removing Security Bars

    A-3 removing security bars figure a-2. Security bar installation removing security bars the security bars should remain in place while the smartswitch 9000-6 slot chassis is operating. Remove the security bars by loosening the two screws that hold each bar in place. Slide the security bars out from ...

  • Page 40

    Smartswitch 9000-6 slot chassis security bars a-4.