    Smartswitch 9000 9c214-2 dc power supply installation guide 9031305-05.

  • Page 3: Notice

    I notice notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5

    Iii notice declaration of conformity addendum application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: ...

  • Page 6

    Notice iv.

  • Page 7: Contents

    V contents chapter 1 introduction using this manual........................................................................................................ 1-1 the 9c214-2 power supply.......................................................................................... 1-1 features ...............

  • Page 8

    Contents vi.

  • Page 9: Chapter 1

    1-1 chapter 1 introduction using this manual read through this manual to become familiar with its contents and gain an understanding of the features and capabilities of the 9c214-2 power supply prior to installation and operation. Chapter 1, introduction , provides a brief description of the 9c214-2...

  • Page 10

    Introduction 1-2 figure 1-1. The 9c214-2 power supply 9c214-2 100% 50% 0% load power supply module status p w r s n b this unit to be installed in a restricted access area in accorcance with the nec or the authority having jurisdiction ! 48/60v 30a max -ol gml status led power supply smb status led ...

  • Page 11

    1-3 introduction features diagnostic controller for management each 9c214-2 power supply has a diagnostic controller. This diagnostic controller includes a microprocessor that monitors the numerous power supply functions available to the network manager via the lcd on the 9c300-1 environmental modul...

  • Page 12: Power Distribution System

    Introduction 1-4 power distribution system the smartswitch 9000 uses a distributed dc power system (figure 1-2) similar to those used in super computers. Three separate power buses are used to distribute dc power. The 48 volt dc system power bus, located on the backplane, powers all modules and the ...

  • Page 13: Related Manuals

    1-5 introduction related manuals the manuals listed below should be used to supplement the procedures and technical data contained in this manual. Smartswitch 9000 installation guide smartswitch 9000 operations guide smartswitch 9000 9c300-1 environmental module user’s guide in addition, each interf...

  • Page 14

    Introduction 1-6.

  • Page 15: Chapter 2

    2-1 chapter 2 installing the 9c214-2 power supply at least one power supply must be installed on the rear of the smartswitch 9000 chassis. Additional power supplies can be added to achieve redundancy. The first power supply is installed on the right side of the chassis (looking from the back of the ...

  • Page 16

    Installing the 9c214-2 power supply 2-2 5. Remove the cover. (keep the cover in the event you need to remove the power supply. The cover must be replaced to protect the connector.) 6. Hold the power supply by the handles on the top and bottom of the unit, and do the following: a. Align the power sup...

  • Page 17

    2-3 installing the 9c214-2 power supply figure 2-1. Installing the 9c214-2 power supply 2 1 . . . . . . . . . . . . . . . . . . . . . . 9c214-2 100% 50% 0% load power supply module status p w r s n b this unit to be installed in a restricted access area in accorcance with the nec or the authority ha...

  • Page 18: Connecting Power Source

    Installing the 9c214-2 power supply 2-4 connecting power source a nominal 48 or 60 volt positive or negative power source can be connected to a 9c214-2 power supply. Follow the appropriate steps starting below to make the proper connection. Connecting a nominal 48/60 volt positive power source the n...

  • Page 19

    2-5 installing the 9c214-2 power supply connecting a nominal -48/-60 volt negative power source the nominal -48/-60 volt negative power source is connected to a 9c214-2 power supply using at least number 10 awg (5 square millimeters) copper wire to which ring or spade terminals that will accept a nu...

  • Page 20

    Installing the 9c214-2 power supply 2-6 powering up a 9c214-2 power supply 1. Turn on the 9c214-2 power supply using the circuit breaker at the bottom right of the power supply. (the power supply uses a soft start feature and does a pre-power diagnostic check. Outputs become enabled within 5 seconds...

  • Page 21: Chapter 3

    3-1 chapter 3 9c214-2 power supply operation the 9c214-2 power supply can operate with input voltages ranging from 36 – 72 positive or negative volts direct current (vdc). Each 9c214-2 provides a maximum of 1000 watts of power to the smartswitch 9000. When two or more power supplies are installed, t...

  • Page 22

    9c214-2 power supply operation 3-2 diagnostic controller the diagnostic controller is composed of a z-80 microprocessor and it’s supporting logic. The diagnostic controller is designed to monitor the power supply’s input and output power parameters as well as the temperature and fan status. In addit...

  • Page 23

    3-3 9c214-2 power supply operation figure 3-1. 9c214-2 power supply lanview leds the pwr status led indicates, by color, the status of a power supply’s input and outputs. The possible colors, states, and descriptions of the pwr status led are listed in table 3-1. Table 3-1. Pwr status led led color ...

  • Page 24

    9c214-2 power supply operation 3-4 the smb status led indicates, by color, the status of the diagnostic controller. The possible colors, states, and descriptions of the smb status led are listed in table 3-2. Table 3-2. Smb status led led color state description green functional fully operational. Y...

  • Page 25

    3-5 9c214-2 power supply operation the power supply level indicator led indicates, by segment number, the percentage of the power supply’s capacity being used. The possible states and descriptions of the power supply level indicator led are listed in table 3-3. Load sharing each 9c214-2 power supply...

  • Page 26

    9c214-2 power supply operation 3-6.

  • Page 27: Chapter 4

    4-1 chapter 4 specifications safety the 9c214-2 power supply, when properly installed on the smartswitch 9000 chassis, complies with the following specifications and standards: safety requirements of: • ul 1950 • csa c22.2 no. 950 • en 60950 • iec 950 • tr-nwt-000063 emi requirements of: • fcc part ...

  • Page 28: Service

    Specifications 4-2 service the 9c214-2 power supply is designed with the following service capability: mtbf (mil-std-217): >200,000 hours projected mttr: hour bellcore standards the 9c214-2 power supply, when properly installed on the smartswitch 9000 chassis, complies with the following standards: ...

  • Page 29: Dc Input

    4-3 specifications dc input each 9c214-2 power supply operates with the following voltage and current. Voltage 36–72 vdc current 30a dc maximum fusing the dc input to the 9c214-2 power supply has a built in 30 amp circuit breaker. Dc input connection the dc input connector is a three connector termi...

  • Page 30