Cabletron Systems 9F120-08 User Manual

Other manuals for 9F120-08: Appendix, User Manual
Manual is about: Cabletron Systems User's Guide 9E531-24 24 Port 10BASE-FL Ethernet Module SmartSwitch 9000

Summary of 9F120-08

  • Page 1

    Smartswitch 9000 9f120-08, 9f122-12 & 9f125-08 user’s guide 9031174-02.

  • Page 3: Notice

    I notice notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5

    Iii notice declaration of conformity addendum application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: ...

  • Page 6: Safety Information

    Notice iv safety information class 1 laser transceivers the 9f120-08, 9f122-12 and 9f125-08 are class 1 laser products the 9f120-08, 9f122-12 and 9f125-08 use class 1 laser transceivers. Read the following safety information before installing or operating these adapters. The class 1 laser transceive...

  • Page 7: Contents

    V contents chapter 1 introduction features........................................................................................................................... 1-1 related manuals............................................................................................................ 1-4 ge...

  • Page 8

    Contents vi.

  • Page 9: Chapter 1

    1-1 chapter 1 introduction the 9f120-08, 9f122-12 and 9f125-08 microlan™ modules are dual attached concentrator modules for the smartswitch 9000 (see figure 1-1). The 9f120-08 provides eight multi-mode fiber master ports, the 9f122-12 provides twelve unshielded twisted pair master ports, and the 9f1...

  • Page 10

    Introduction 1-2 connectivity the front panel master port connections are via standard fiber fddi mic connectors or rj-45 unshielded twisted pair ports. Multiple modules can combine to provide connections for up to 168 fddi stations. All fddi stations connected to the master ports are directly attac...

  • Page 11

    1-3 introduction figure 1-1. The concentrator modules m 1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 1 5 6 4 8 2 3 7 f d d i smb cpu fnb 9f120-08 fddi smb cpu fnb 9f122-12 fddi 1 4 2 3 5 6 8 7 m 1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 1 5 6 4 8 2 3 7 f d d i smb cpu fnb 9f125-08 fddi.

  • Page 12: Related Manuals

    Introduction 1-4 related manuals the manuals listed below should be used to supplement the procedures and technical data contained in this manual. Smartswitch 9000 installation guide smartswitch 9000 operations guide smartswitch 9000 9c300-1 environmental module user’s guide smartswitch 9000 9c214-1...

  • Page 13: Chapter 2

    2-1 chapter 2 installing the microlan modules smartswitch 9000 microlan modules can be installed in any of the 14 slots that are available. To install, follow the steps below: 1. Remove the blank panel, covering the slot in which the microlan module will be installed. All other slots must remain cov...

  • Page 14

    Installing the microlan modules 2-2 figure 2-1. Installing the microlan module metal back-panel module guides module jack for esd wrist strap plastic tab warning: ensure that the circuit card is between the card guides. Lock down the top and bottom plastic tabs at the same time, applying even pressu...

  • Page 15: The Reset Switch

    2-3 installing the microlan modules the reset switch the reset switch is located on the front panel, under the top plastic tab, as shown in figure 2-2. It serves two functions: • pressing the reset switch twice within three seconds causes the processor (i960) to reset. • pressing and holding the swi...

  • Page 16: User-Accessible Components

    Installing the microlan modules 2-4 user-accessible components figure 2-3 shows the various components that are accessible to the user. These consist of an eight-position dip switch (explained in the next section), replaceable proms and sockets for ram. These will be used for future upgrades. Instru...

  • Page 17

    2-5 installing the microlan modules setting the module card dip switch an eight-switch dip switch is located on the module card, as shown in figure 2-3 and figure 2-4. The functions of the switches are listed in table 2-1. Figure 2-4. Location of module dip switch 1 2 3 4 5 6 7 8.

  • Page 18

    Installing the microlan modules 2-6 see the cautions at the end of this table. Table 2-1. Function of dip switch switch function description 8 clear password 1 when toggled, this switch clears user-entered passwords stored in nvram, and restores the default passwords. Once reset you can use the defa...

  • Page 19: Chapter 3

    3-1 chapter 3 operation the microlan modules, as shown in figure 3-1, provide concentrator ports that connect directly to the fnb bus. Each port can connect to either ring (fnb-1 or fnb-2). This is software configurable via local or remote management. Figure 3-1. Block diagram flexible network bus (...

  • Page 20: System Management Buses

    Operation 3-2 system management buses there are two management channels within the smartswitch 9000 system: the smb-1 and the smb-10. These buses provide out-of-band management and inter- module management communication. Smb-1 bus the smb-1 is a 1 mbps management bus located within the smartswitch 9...

  • Page 21: System Diagnostic Controller

    3-3 operation system diagnostic controller this diagnostic controller is composed of a z-80 microprocessor and its supporting logic. The diagnostic controller is designed to control the power-up sequencing of modules, monitor the concentrator modules input and output power parameters, keep watch ove...

  • Page 22

    Operation 3-4.

  • Page 23: Chapter 4

    4-1 chapter 4 lanview leds the front panel lanview leds indicate the status of the module and may be used as an aid in troubleshooting. Shown in figure 4-1 is the lanview leds of the concentrator modules. Figure 4-1. The lanview leds m 1 1 5 6 4 8 2 3 7 f d d i smb cpu fnb 9f120-08 fddi smb cpu fnb ...

  • Page 24

    Lanview leds 4-2 the functions of the system management bus (smb) and the cpu leds are listed in table 4-1. The functions of the fnb receive leds are listed in table 4-2. The functions of the fnb transmit leds are listed in table 4-2. Table 4-1. Smb and cpu leds led color state description green fun...

  • Page 25

    4-3 lanview leds there is one fddi port led for each master port. The functions of the fddi port leds are listed in table 4-4. Table 4-4. Fddi status leds led color state green link, activity, port enabled yellow link, no activity, port enabled red no link, port disabled red (flashing) link, port di...

  • Page 26

    Lanview leds 4-4.

  • Page 27: Chapter 5

    5-1 chapter 5 specifications safety this equipment meets the following safety requirements: • ul 1950 • csa c22.2 no. 950 • en 60950 • iec 950 • emi requirements of fcc part 15 class a • en 55022 class a • vcci class i • emc the following requirements: en 50082-1 iec 801-2 esd iec 801-3 radiated sus...

  • Page 28: Physical

    Specifications 5-2 physical dimensions: 35.0 d x 44.0 h x 3.0 w centimeters (13.8 d x 17.4 h x 1.2 w inches) weight: unit: 1360.7 gr. (3 lb) shipping: 1814.4 gr. (4 lb) link distance 9f120-08 up to 2 kilometers on multimode fiber-optic cable as specified by ansi mmf-pmd. 9f125-08 40 kilometers (max)...