  • Page 1

    Mmac-m5fnb multi-media access center overview and setup guide cabletron systems, p.O. Box 5005, rochester, n.H. 03867-0505.

  • Page 2: Notice

    Notice i notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 3: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 4: Vcci Notice

    Notice iii vcci notice this equipment is in the 1st class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the voluntary control council for interference by information technology equipment (vcci) aimed at preventing radio interfe...

  • Page 5: Contents

    Contents v contents chapter 1 introduction 1.1 using this manual .................................................................... 1-1 1.2 using the mmac-m5fnb manual set .................................... 1-2 1.3 getting help .......................................................................

  • Page 6: Chapter 1

    Introduction page 1-1 chapter 1 introduction the mmac-m5fnb™ multi media access center offers maximum flexibility and convenience in the design and operation of your network. The enclosure provides space for one repeater/management module and up to five media interface modules (mim™); or, by removin...

  • Page 7

    Introduction page 1-2 1.2 using the mmac-m5fnb manual set other manuals have been developed for the repeater/management modules and for each mim that can be installed in your mmac-m5fnb. These manuals explain how to install the individual modules into the mmac-m5fnb, how to attach cable segments to ...

  • Page 8

    Introduction page 1-3 by internet mail: support@ctron.Com by fax: (603) 337-3075 by bbs: (603) 335-3358 (4 lines available) 1.4 the mmac-m5fnb multi media access center the cabletron systems mmac-m5fnb is a complete modular approach to integrated networks. The mmac-m5fnb supports local area networks...

  • Page 9

    Introduction page 1-4 figure 1-1. Mmac-m5fnb with optional mims 1.5 mmac-m5fnb features universal power supply the mmac-m5fnb power supply senses and automatically adjusts to the input voltage and frequency. No additional adjustments are necessary. Built-in power supply protection the power supply m...

  • Page 10

    Introduction page 1-5 supply requires ac power cycling (turn power switch off, then on again) to recover. A fault led on the power supply module indicates when an over current condition has occurred. Note: if you remove, then re-insert, the fan tray with no mims installed in the chassis and the powe...

  • Page 11

    Introduction page 1-6 if a redundant power supply is not desired, a fifth mim can be installed in the second power supply module slot. Note: the power requirements of some fddi mim configurations require dual power supplies. Consult the appropriate manuals for details. Hot swapping you have the opti...

  • Page 12

    Introduction page 1-7 rack mountable chassis the mmac-m5fnb chassis can be mounted into a standard 19" (48.26 cm) equipment rack. Separate rack mount brackets are included that allow the unit to be flush mounted or recessed 3" from the front plane of the rack mount unit for safety and ease of networ...

  • Page 13: Chapter 2

    Installation requirements and specifications page 2-1 chapter 2 installation requirements and specifications this chapter describes the following: • site guidelines that must be met before installing an mmac-m5fnb onto your network • mmac configuration guidelines • operating specifications for the m...

  • Page 14

    Installation requirements and specifications page 2-2 • a usa standard 3 prong power receptacle must be located within 2.13 m (7 ft.) of the site. • the temperature of the location must be maintained between 5 ° and 40 ° c (41 ° to 104 ° f). Temperature changes of greater than 10 ° c (18 ° f) per ho...

  • Page 15

    Installation requirements and specifications page 2-3 physical m5fnb dimensions: 14.8" high x 17" wide x 14.8" long (37.6 cm high x 43.2 cm wide x 37.6 cm long) weight: 17.3 lb (7.8 kg) with fan tray m5psm dimensions: 9.5" high x 3" wide x 13.625" deep (24.1 cm high x 7.6 cm wide x 34.6 cm deep) wei...

  • Page 16

    Installation requirements and specifications page 2-4 note: the maximum power out of each m5psm power supply will not exceed 300 watts. This unit is intended for indoor use only, and must be used with a two-conductor-plus-ground power supply cord with a minimum ho5vv-f cord, minimum 0.75 mm 2 diamet...

  • Page 17

    Installation requirements and specifications page 2-5 figure 2-1. The mmac-m5psm leds ok when lit, this green led indicates that the (power supply) power supply module is operating correctly; a signal is also sent to the management/repeater module to indicate that the power supply is functioning pro...

  • Page 18

    Installation requirements and specifications page 2-6 current condition has been corrected, the power supply requires ac power cycling (turn the power switch off for at least one second, then on again) to recover. Fan tray led this led is green when all the fans are operating properly. The led turns...

  • Page 19

    Installation requirements and specifications page 2-7 safety designed in accordance with ul1950, csa c22.2 no. 950, iec950, and en60950. Meets the emi requirement of fcc part 15 class a and en55022 class a. Meets the immunity requirements of en50082-1. This unit must be assembled and used in accorda...

  • Page 20: Chapter 3

    Mmac-m5fnb setup page 3-1 chapter 3 mmac-m5fnb setup this chapter contains instructions to help you set up cabletron systems’ mmac-m5fnb. You will not need any special tools or equipment to set up the mmac-m5fnb, but you must follow all guidelines listed in chapter 2, installation requirements and s...

  • Page 21

    Mmac-m5fnb setup page 3-2 3.2 setting up the mmac-m5fnb the following sections list the steps necessary to set up your mmac-m5fnb, including installing the mmac-m5fnb in the desired location, inserting the fan tray, and inserting the power supply module(s). 3.2.1 rack mounting the mmac-m5fnb to moun...

  • Page 22

    Mmac-m5fnb setup page 3-3 figure 3-1. Installing the m5fnb into a rack 3. Insert the screws through the holes on the mounting bracket and into the screw holes on the mmac-m5fnb. 4. Tighten the screws until the mounting bracket is securely attached to the unit. 5. Repeat steps 2-4 for the second rack...

  • Page 23

    Mmac-m5fnb setup page 3-4 7. Align the slots on each mounting bracket with the desired holes on the equipment rack. 8. Insert a bolt (item 5) through the slot in each of the mounting brackets and into the threaded holes in the equipment rack (item 6). Secure bolts with locking washers. 9. Tighten th...

  • Page 24

    Mmac-m5fnb setup page 3-5 figure 3-2. Cable tie tray installation 3.2.3 inserting the fan tray the mmac-m5fnb is equipped with a removable fan tray that allows for easy periodic cleaning and/or replacement if a problem occurs with fan operation. To insert the fan tray in the mmac-m5fnb: 1. Hold the ...

  • Page 25

    Mmac-m5fnb setup page 3-6 4. When the mmac-m5fnb is ready to be turned on, observe the led on the front of the fan tray. This led should be red for a moment after you turn on the power switch, and then change to green to indicate that all the fans are operating properly. If this led remains red, it ...

  • Page 26

    Mmac-m5fnb setup page 3-7 mmac-m5psms are installed, the load is evenly distributed; if one power supply fails for any reason other than a shorted dc backplane, the second power supply assumes the load. Note: the power requirements of some fddi configurations require dual power supplies. The mmac-m5...

  • Page 27

    Mmac-m5fnb setup page 3-8 install the m5psm(s) into your mmac-m5fnb as follows: 1. Unpack the m5psm by removing it from the shipping box and sliding the two foam end caps off the unit. Save the shipping box and materials in the event the unit must be reshipped. 2. Remove the m5psm from its protectiv...

  • Page 28

    Mmac-m5fnb setup page 3-9 figure 3-5. Installing the power supply module(s) 5. Tighten the knurled knobs to secure the m5psm to the mmac-m5fnb. 6. If you are installing an additional m5psm, repeat steps 3 - 5. After you have finished installing the power supply module(s), the mmac-m5fnb is ready to ...

  • Page 29

    Mmac-m5fnb setup page 3-10 to attach the security bars to the chassis: 1. Install all power supplies and mims in the m5fnb hub, as desired; be sure to install panels over any empty slots. 2. Place one of the security bars across the top row of knurled knobs securing the modules and panels to the cha...

  • Page 30

    Mmac-m5fnb setup page 3-11 3.2.6 powering up the mmac-m5fnb power up the mmac-m5fnb as follows: 1. If the mmac-m5fnb will not be rack mounted, place it on the selected site. 2. Plug a power cord into the power receptacle located on the front of each installed power supply. 3. Plug the power cord(s) ...