Cabletron Systems MMAC-Plus 9F116-01 User Manual

Other manuals for MMAC-Plus 9F116-01: User Manual, Reference Manual
Manual is about: Frame relay module for MMAC-Plus

Summary of MMAC-Plus 9F116-01

  • Page 1

    Smartswitch 9000 9f116-01 user’s guide 9031184-01.

  • Page 3: Notice

    I notice notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5

    Iii notice declaration of conformity addendum application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: ...

  • Page 6

    Notice iv.

  • Page 7: Contents

    V contents chapter 1 introduction features........................................................................................................................... 1-1 related manuals............................................................................................................ 1-4 ge...

  • Page 8

    Contents vi.

  • Page 9: Chapter 1

    1-1 chapter 1 introduction the 9f116-01 microlan™ module (shown in figure 1-1) is a two port fddi bridge/router used to connect an external fddi network to one of the two fnb networks, fnb-1 or fnb-2, on the smartswitch 9000 fnb backplane. Another configuration option allows the module to bridge/rou...

  • Page 10

    Introduction 1-2 spanning tree algorithm the 9f116-01 supports both ieee 802.1d and dec spanning tree algorithm (sta) protocols. Connectivity the 9f116-01 provides one fddi dual attached connector pair from the module front panel. This connector pair allows the 9f116-01 to act as a das (with two fpi...

  • Page 11

    1-3 introduction figure 1-1. The 9f116-01 module a b f d d i 1 9f116-01 fddi smb cpu fnb 1 1.

  • Page 12: Related Manuals

    Introduction 1-4 related manuals the manuals listed below should be used to supplement the procedures and technical data contained in this manual. Smartswitch 9000 installation guide smartswitch 9000 operations guide smartswitch 9000 9c300-1 environmental module user’s guide smartswitch 9000 9c214-1...

  • Page 13: Chapter 2

    2-1 chapter 2 installing the microlan modules smartswitch 9000 microlan modules can be installed in any of the 14 slots that are available. To install, follow the steps below: 1. Remove the blank panel, covering the slot in which the microlan module will be installed. All other slots must remain cov...

  • Page 14

    Installing the microlan modules 2-2 figure 2-1. Installing the microlan module metal back-panel module guides module jack for esd wrist strap plastic tab warning: ensure that the circuit card is between the card guides. Lock down the top and bottom plastic tabs at the same time, applying even pressu...

  • Page 15: The Reset Switch

    2-3 installing the microlan modules the reset switch the reset switch is located on the front panel, under the top plastic tab as shown in figure 2-2. It serves two functions: • pressing the reset switch twice within three seconds causes the processor (i960) to reset. • pressing and holding the swit...

  • Page 16: User-Accessible Components

    Installing the microlan modules 2-4 user-accessible components figure 2-3 shows the various components that are accessible to the user. These consist of an eight position dip switch (explained in the next section), replaceable proms, and sockets for ram. These will be used for future upgrades. Instr...

  • Page 17

    2-5 installing the microlan modules setting the module card dip switch an eight switch dip switch is located on the module card as shown in figure 2-3 and figure 2-4. The functions of the switches are listed in table 2-1. Figure 2-4. Location of module dip switch 1 2 3 4 5 6 7 8.

  • Page 18

    Installing the microlan modules 2-6 see the cautions at the end of this table. Table 2-1. Function of dip switch switch function description 8 clear password 1 when toggled, this switch clears user-entered passwords stored in nvram and restores the default passwords. Once reset you can use the defau...

  • Page 19: Installing An Fpim

    2-7 installing the microlan modules installing an fpim the 9f116-01 microlan module is shipped without fpims. To install an fpim, follow the procedure below: 1. Remove the module if it is installed in the smartswitch 9000 chassis. 2. Remove the blank front cover over the fpim slot. 3. Install the fp...

  • Page 20

    Installing the microlan modules 2-8.

  • Page 21: Chapter 3

    3-1 chapter 3 operation the 9f116-01 provides connectivity between two of the three available interfaces: the front panel and both fddi rings on the fnb backplane (fnb-1 and fnb-2). Bridging/routing can occur between any two interfaces, front panel to either fnb ring or between the fnb rings (fnb-1 ...

  • Page 22: System Management Buses

    Operation 3-2 system management buses there are two management channels within the smartswitch 9000 system: the smb-1 and the smb-10. These buses provide out-of-band management and inter- module management communication. Smb-1 bus the smb-1 is a 1 mbps management bus located within the smartswitch 9...

  • Page 23: Dc/dc Converter

    3-3 operation dc/dc converter the dc/dc converter converts the 48 vdc on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller controls the operation of the dc/dc converter. Fnb interface smartswitch 9000 modules are designed with on...

  • Page 24

    Operation 3-4.

  • Page 25: Chapter 4

    4-1 chapter 4 lanview leds the front panel lanview leds indicate the status of the module and may be used as an aid in troubleshooting. Shown in figure 4-1 are the lanview leds of the 9f116-01 module. Figure 4-1. 9f116-01 lanview leds a b f d d i 1 9f116-01 fddi smb cpu fnb 1 1 system status fnb sta...

  • Page 26

    Lanview leds 4-2 the functions of the system management bus (smb) and cpu leds are listed in table 4-1. The information displayed by the fnb status leds, is dependent on how the bridging function is configured. When the front panel port is bridged to one of the fnb rings (fnb-1 or fnb-2), the leds l...

  • Page 27

    4-3 lanview leds the fddi status leds display the status when bridging to the front panel port from either fnb ring. The “a” and “b” leds indicate the status of the a and b ports. The “p” and “s” leds indicate the status of the primary and secondary fddi rings. When bridging between fnb rings, the f...

  • Page 28

    Lanview leds 4-4 green yellow red yellow wrap a, no mac on primary yellow green red green wrap b, mac on primary yellow yellow red green wrap b, no mac on primary green green red green wrap ab, mac on primary green off off green bypass primary & secondary green red red green twisted a-a, b-b yellow ...

  • Page 29: Chapter 5

    5-1 chapter 5 general specifications the specifications of the 9f116-01 microlan module are as follows: safety this equipment meets the following safety requirements: • ul 1950 • csa c22.2 no. 950 • en 60950 • iec 950 • emi requirements of fcc part 15 class a • en 55022 class a • vcci class i • emc ...

  • Page 30: Physical

    General specifications 5-2 physical dimensions: 35.0 d x 44.0 h x 3.0 w centimeters (13.8 d x 17.4 h x 1.2 w inches) weight: unit: 1.36 kg. (3 lb) shipping: 1.81 kg. (4 lb).

  • Page 31: Appendix A

    A-1 appendix a fpim specifications this smartswitch 9000 module uses fiber port interface modules (fpim) to provide front panel cable connections. The fpims are user-installable. See the section titled installing an fpim on page 2-7. Fpim-00 the fpim-00 has a mic style connector supporting a multimo...

  • Page 32: Fpim-02 and Fpim-04

    Fpim specifications a-2 transmitter power parameters are listed in table a-2. The link distance is up to 2 kilometers on the multimode fiber-optic cable as specified by ansi mmf-pmd. Fpim-02 and fpim-04 the fpim-02 has an rj-45 connector supporting an unshielded twisted pair (utp) connection. The fp...

  • Page 33: Fpim-05

    A-3 fpim specifications fpim-05 the fpim-05 has a mic style connector supporting a single-mode fiber connection. The specifications are listed in table a-4. The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on single mode fiber-optic cable as specified by ansi smf-pmd. Table...

  • Page 34

    Fpim specifications a-4.