Cabletron Systems MMAC-Plus 9G426-02 Reference Manual

Other manuals for MMAC-Plus 9G426-02: User Manual, User Manual
Manual is about: Frame relay module for MMAC-Plus

Summary of MMAC-Plus 9G426-02

  • Page 1

    9032028 mmac-plus ™ module local management 9g426-02 module specific appendix.

  • Page 3: Appendix

    1 appendix 9g426-02 module specific information introduction this appendix contains local management information that is specific to the 9g426-02 ethernet module. The 9g426-02 ethernet module is a 3-port switching module with: • 2 front panel gigabit ethernet ports • 1 internal network bus (inb) bac...

  • Page 4: Module Interface Codes

    9g426-02 module specific information 2 module interface codes the 9g426-02 module has 7 interfaces. Table 1 lists the identifying number, name, and description of each interface. Use the numbers listed in table 1 to configure the module’s default interface (see the general configuration screen). Tab...

  • Page 5: General Configuration Screen

    3 9g426-02 module specific information general configuration screen the general configuration screen (figure 1), displays information about the selected module and allows you to set the following general parameters: • module date and time • screen refresh and lockout time • host ip address • subnet ...

  • Page 6

    9g426-02 module specific information 4 general configuration screen fields the following information briefly explains each general configuration screen field. Module serial # displays the serial number of the selected module. Module board revision displays the version number of the selected module. ...

  • Page 7

    5 9g426-02 module specific information screen lockout time contains the maximum number of minutes that the local management application will display a module’s screen while pending input or action from a user. For example, if you enter 5 in this field, users will have up to five minutes to respond i...

  • Page 8: Port Statistics Screen

    9g426-02 module specific information 6 port statistics screen the port statistics screen (figure 2), displays information and statistics about the module’s ethernet ports. Figure 2. Port statistics screen mmac-plus local management port statistics module name: 9g426-02 firmware revision: 01.00.00 sl...

  • Page 9

    7 9g426-02 module specific information port statistics screen fields the following information briefly explains each port statistics screen field. Port # indicates the current port for which statistics are displayed. Octets displays the number of octets transmitted and received on the port. Packets ...

  • Page 10

    9g426-02 module specific information 8 multicasts displays the number of multicasts received. Link status indicates whether there is a physical connection from this port to another device. One of the following values appears: • link - there is a link signal present; there is a valid physical connect...

  • Page 11

    9 9g426-02 module specific information displaying statistics for another port to display statistics for another port: 1. Use the arrow keys to highlight the port # field at the bottom of the screen. 2. Press the space bar to increment (or press the backspace key to decrement) the port number. Exitin...

  • Page 12

    9g426-02 module specific information 10