Cabletron Systems SmartSwitch 9A100 User Manual

Other manuals for SmartSwitch 9A100: User Manual, Upgrade Instructions, Installation And Setup Manual
Manual is about: ATM Switch

Summary of SmartSwitch 9A100

  • Page 1

    Smartswitch 9a100 user guide 35 industrial way rochester, nh 03866 usa (603) 332-9400 part number 04-0049-01 rev. A order number 9032628.

  • Page 2

    Ii smartswitch 9a100 user guide notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hard...

  • Page 3

    Smartswitch 9a100 user guide iii fcc class a notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may...

  • Page 4

    Iv smartswitch 9a100 user guide declaration of conformity addendum application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way p. O. Box 5005 rochester, nh 03866 product name: smartswitch 9a100 european representati...

  • Page 5

    Smartswitch 9a100 user guide v safety information class 1 laser transceivers the 6a-iom-29-4, 6a-iom-29-4-ir, 6a-iom-29-4-lr, 6a-iom-39-1 and 6a-iom-39-1-lr connectors use class 1 laser transceivers. Read the following safety information before installing or operating the 6a-iom-29-4. The class 1 la...

  • Page 6

    Vi smartswitch 9a100 user guide fiber optic protective caps %"¤›apm read before removing fiber optic protective caps. Cable assemblies and mmf/smf ports are shipped with protective caps to prevent contamination. To avoid contamination, replace port caps on all fiber optic devices when not in use. Ca...

  • Page 7

    Smartswitch 9a100 user guide vii regulatory compliance summary safety the smartswitch 9a100 meets the safety requirements of ul 1950, csa c22.2 no. 950, en 60950, iec 950, and 73/23/eec. Emc the smartswitch 9a100 meets the emc requirements of fcc part 15, en 55022, csa c108.8, vcci v-3/93.01, en 500...

  • Page 8

    Viii smartswitch 9a100 user guide revision history document name: smartswitch 9a100 user guide document part number: 04-0049-01 rev. A document order number: 9032628 author: carre gibson editor: ayesha maqsood illustrator: michael fornalski date revision description may 1998 04-0049-01 rev. A initia...

  • Page 9

    Smartswitch 9a100 user guide ix table of contents 1 introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 2 switch installation and setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.1 unpacking the switch...

  • Page 10

    X smartswitch 9a100 user guide table of contents 4.5 pvc connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 4.5.1 point-to-point pvcs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 11

    Smartswitch 9a100 user guide xi table of contents c.3 electronic services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1 c.4 placing a support call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 12

    Xii smartswitch 9a100 user guide table of contents.

  • Page 13

    Smartswitch 9a100 user guide xiii list of figures figure 2-1 smartswitch 9a100-04 front panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 figure 2-2 installing the smartswitch 9a100 . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 14

    Xiv smartswitch 9a100 user guide list of figures.

  • Page 15

    Smartswitch 9a100 user guide xv list of tables table 2-1 i/o module id numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 table 2-2 ds3 and e3 module settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 16

    Xvi smartswitch 9a100 user guide list of tables.

  • Page 17

    Smartswitch 9a100 user guide 1-1 1 introduction welcome to the smartswitch 9a100 user guide. The smartswitch 9a100 atm switch is a module that fits into the smartswitch 9000 chassis. You can install up to seven smartswitch 9a100 switches into a 14-slot smartswitch 9000 chassis; or up to three switch...

  • Page 18

    1-2 smartswitch 9a100 user guide introduction.

  • Page 19

    Smartswitch 9a100 user guide 2-1 2 switch installation and setup after you read this chapter, you will be able to perform the following tasks: u install the smartswitch 9a100 switch module into the smartswitch 9000 chassis u complete the initial configuration u use the console interface u install th...

  • Page 20

    2-2 smartswitch 9a100 user guide inspecting the switch switch installation and setup 2.2 inspecting the switch depending on the configuration ordered, your switch looks similar to the unit in figure 2-1. The smartswitch 9a100-04 has four i/o modules. Figure 2-1 smartswitch 9a100-04 front panel inspe...

  • Page 21

    Smartswitch 9a100 user guide 2-3 switch installation and setup inspecting the switch if the hardware configuration is incorrect, contact cabletron customer support immediately. 2.2.1 ds3 and e3 i/o module configuration table 2-2 shows the pre-configured values for both the ds3 (6a-iom-67-4) and e3 (...

  • Page 22

    2-4 smartswitch 9a100 user guide installing the switch switch installation and setup 2.3 installing the switch the smartswitch 9a100 is hot swappable, meaning that you can install and remove it without turning off or unplugging the smartswitch 9000 chassis. The following list shows how many switch m...

  • Page 23

    Smartswitch 9a100 user guide 2-5 switch installation and setup installing the switch figure 2-2 installing the smartswitch 9a100 rotate ejector to lock in place metal backpanel card guides circuit card.

  • Page 24

    2-6 smartswitch 9a100 user guide configuring the switch switch installation and setup 2.4 configuring the switch initial configuration of your smartswitch 9a100 switch consists of setting the name, ethernet ip address, and subnet mask. Once these tasks are complete, the switch can be reached through...

  • Page 25

    Smartswitch 9a100 user guide 2-7 switch installation and setup configuring the switch figure 2-3 smartswitch 9a100 console and network connections –• start the dumb terminal or pc and its terminal emulation software. •• when power is applied to the smartswitch 9a100, the module emits a series of dia...

  • Page 26

    2-8 smartswitch 9a100 user guide using the console switch installation and setup n• next, the switch prompts for the information necessary to make the switch accessible through your ethernet network u switch name u ip address u subnet mask s¬• after you enter these parameters and reboot the switch, ...

  • Page 27

    Smartswitch 9a100 user guide 2-9 switch installation and setup using the console all console commands use the syntax: operator switch-attribute [ ... ] where the operator is one of the following: show ( display ): show the current values used by a switch-attribute. Add ( create ): add a new instance...

  • Page 28

    2-10 smartswitch 9a100 user guide using the console switch installation and setup if you don’t specify parameters with the command, the console prompts you for an input value and provides a default value displayed in parenthesis. For example, if you enter show portconfig without specifying a port (a...

  • Page 29

    Smartswitch 9a100 user guide 2-11 switch installation and setup using the console the above example creates an alias ( traffic ) that can be entered in place of the command set switchtrafficcongestion . For example: smartswitch # traffic queue1efcithreshold(4096) : queue2efcithreshold(4096) : queue3...

  • Page 30

    2-12 smartswitch 9a100 user guide smartswitch atm administrator switch installation and setup 2.5.5 console help the console provides several levels of help for console commands. For example, to list the switch attributes that can be used with a particular operator, enter the word help (or ? ) follo...

  • Page 31

    Smartswitch 9a100 user guide 2-13 switch installation and setup smartswitch atm administrator u alarm management u switch discovery additionally, the smartswitch atm administrator provides the following capabilities that are not available from the console interface: u use a graphical interface u per...

  • Page 32

    2-14 smartswitch 9a100 user guide smartswitch atm administrator switch installation and setup smartswitch atm administrator can be installed on a pc running windows nt 4.0, windows nt 3.51, or windows 95, and requires the following pc hardware configuration: u pentium 133 mhz or faster processor u 2...

  • Page 33

    Smartswitch 9a100 user guide 2-15 switch installation and setup smartswitch atm administrator 2.6.2 starting smartswitch atm administrator the first time when you use smartswitch atm administrator for the first time, you should change the default passwords to prevent unauthorized access to the appli...

  • Page 34

    2-16 smartswitch 9a100 user guide smartswitch atm administrator switch installation and setup.

  • Page 35

    Smartswitch 9a100 user guide 3-1 3 ip over atm and lane this chapter describes working with the smartswitch 9a100 ip over atm vlan and emulated lan capabilities. At the end of this chapter you will be able to use your smartswitch 9a100 switch to • create an ip over atm vlan • create an emulated ethe...

  • Page 36

    3-2 smartswitch 9a100 user guide %•f"›amv˜"m˜,6˜p¦f•˜":1˜=/"2 ˜˜,6˜3¦f•˜":1˜"m=˜/"2' 3. Enter the show client command to make sure the client is operational and to obtain the 20-byte atm address of the arp server. For instance, if you used the client number (client 1) from the example in step 2, ent...

  • Page 37

    Smartswitch 9a100 user guide 3-3 ,6˜3¦f•˜":1˜"m=˜/"2' %•f"›amv˜"m˜'h¤d"›f=˜/"2˜˜ note if configured devices fail to join the vlan, see chapter 4, section 4.2.2, “uni routes.” also, see chapter 5, section 5.1, “troubleshooting ip over atm.” you have completed the process for creating an ip over atm v...

  • Page 38

    3-4 smartswitch 9a100 user guide %•f"›amv˜"m˜'h¤d"›f=˜/"2 ˜˜,6˜3¦f•˜":1˜"m=˜/"2' 1. Enter the start lecs command to activate lane server services on this switch. Smartswitch # start lecs notice - 'lecs' ***** lecs started ***** smartswitch # 2. Create an elan on your smartswitch 9a100 switch by exec...

  • Page 39

    Smartswitch 9a100 user guide 3-5 ,6˜3¦f•˜":1˜"m=˜/"2' %•f"›amv˜"m˜'h¤d"›f=˜/"2˜˜ 4. Enter the show client command to make certain that the client is operational. Smartswitch # show client 1 lane client 1 ============================================================================ client state : oper...

  • Page 40

    3-6 smartswitch 9a100 user guide %•f"›amv˜"m˜'h¤d"›f=˜/"2 ˜˜,6˜3¦f•˜":1˜"m=˜/"2' 3.2.1 atm addressing for lan emulation the smartswitch 9a100 provides a default format for atm addresses used by lan emulation. The default format is constructed as follows: netprefix + the mac address of the device + a...

  • Page 41

    Smartswitch 9a100 user guide 3-7 ,6˜3¦f•˜":1˜"m=˜/"2' %•f"›amv˜"m˜'h¤d"›f=˜/"2˜˜ 3.2.3 switch clients it is important to understand the concept of smartswitch 9a100 switch client connections. A client connection is actually a connection between the vlan and the smartswitch 9a100 cpu; this cpu connec...

  • Page 42

    3-8 smartswitch 9a100 user guide %•f"›amv˜"m˜'h¤d"›f=˜/"2 ˜˜,6˜3¦f•˜":1˜"m=˜/"2'.

  • Page 43

    Smartswitch 9a100 user guide 4-1 4 switch administration this chapter contains software and hardware procedures that you might need to perform on your smartswitch 9a100 switch. These procedures include • backing up switch configuration • creating routes and connecting switches • using switch events ...

  • Page 44

    4-2 smartswitch 9a100 user guide atm routing switch administration the switch stores the ip address of the tftp server, the path, and the backup file name. The next time you enter the backup or restore commands, these values are presented as the default ip address and path. For example, when you ent...

  • Page 45

    Smartswitch 9a100 user guide 4-3 switch administration atm routing 4. Enter the add atmroute command to create a static route to the iisp device: smartswitch # add atmroute portnumber(a1) : b2 atmaddress() : 52:00:00:00:00:00:00:00:00:00:14:51:80 prefixlength(104) : index(0) : type(internal) :exteri...

  • Page 46

    4-4 smartswitch 9a100 user guide atm routing switch administration note dotted lines in the diagrams below represent one-way routes to the devices pointed to by the arrowheads. Each route is defined on the device from which the dotted line originates. Figure 4-1 iisp route across pnni domain a secon...

  • Page 47

    Smartswitch 9a100 user guide 4-5 switch administration atm routing 4.2.2 uni routes use the add atmroute command to create uni routes. For example, connect an end station adapter (with mac address 00:11:22:33:44:55) to port a2 of the smartswitch 9a100. If the adapter does not support ilmi or its ilm...

  • Page 48

    4-6 smartswitch 9a100 user guide atm routing switch administration 4.2.3 route metrics route metrics are assigned to routes using a metric tag (one of the input parameters for add atmroute ). The metric tag specifies a particular pair of incoming and outgoing metrics contained within a list of metri...

  • Page 49

    Smartswitch 9a100 user guide 4-7 switch administration ip routing enter show pnnimetric to view the newly created metric pair: smartswitch # show pnnimetrics metrics(all) : metrics metrics tag direction index gcac clp admin wt service categories ======================================================...

  • Page 50

    4-8 smartswitch 9a100 user guide ip routing switch administration note smartswitch 9a100 ip routing performance is inadequate for routing between vlans. If you need to create routes between vlans on your smartswitch 9a100, use a router equipped with an atm interface. Consult cabletron customer suppo...

  • Page 51

    Smartswitch 9a100 user guide 4-9 switch administration events and alarms figure 4-3 ip routing through sw1 for connectivity to the ethernet network 4.4 events and alarms the smartswitch 9a100 switch records and reports its operation in real-time through the use of events and alarms. An event is an o...

  • Page 52

    4-10 smartswitch 9a100 user guide events and alarms switch administration 4.4.2 viewing events and alarms use the show events command to view a list of the currently logged events. For example, smartswitch # show events index(all) : 0 minor event 000:00:08:410 ---------------------------------------...

  • Page 53

    Smartswitch 9a100 user guide 4-11 switch administration pvc connections use the show alarms command to view a list of the currently logged alarms. For example, smartswitch # show alarms index(all) : 0 000:00:31:164 --------------------------------------------------- lecs operational ----------------...

  • Page 54

    4-12 smartswitch 9a100 user guide pvc connections switch administration 4.5.1 point-to-point pvcs the procedure for setting up a pvc connection between two end nodes through the smartswitch 9a100 consists of specifying the ports and the virtual path and virtual channel identifiers (vpi and vci). 1. ...

  • Page 55

    Smartswitch 9a100 user guide 4-13 switch administration pvc connections 4.5.2 point-to-multipoint pvcs instructions in this section describe how to set up a point-to-multipoint connection through your smartswitch 9a100. Example: create a point-to-multipoint connection between a broadcasting workstat...

  • Page 56

    4-14 smartswitch 9a100 user guide pvc connections switch administration 3. Use add pvc to successively create point-to-multipoint pvcs for ports b2, b3, and c1. Smartswitch # add pvc conntype(ptp) : pmp lowportid() : a1 lowvpi() : 0 lowvci() : 101 highportid() : b2 highvpi() : 0 highvci() : 101 fwdt...

  • Page 57

    Smartswitch 9a100 user guide 4-15 switch administration pvc connections 4.5.4 non-zero vpis the smartswitch 9a100 uses 12 bits to define vpi/vci pairs. The vccmask determines how many of the 12 bits are used for the vpi and how many are used for the vci. The vccmask uses a 2-bit register to hold fou...

  • Page 58

    4-16 smartswitch 9a100 user guide pvc connections switch administration 3. Use the set portconfig command to reconfigure a port to use the new values for vpi and vci. For example, to set up a pvc on port a1 using the new vpi/vci bit ranges (3/9), enter smartswitch # set portconfig a1 portadminstatus...

  • Page 59

    Smartswitch 9a100 user guide 4-17 switch administration traffic management 4.6 traffic management this section describes how the smartswitch 9a100 manages bandwidth and congestion. It briefly describes console commands that affect how the smartswitch 9a100 manages traffic. This section also provides...

  • Page 60

    4-18 smartswitch 9a100 user guide traffic management switch administration use the trafficdescriptor commands to view, create, and delete traffic descriptors. For example, enter the show trafficdescriptor command to view all currently defined traffic descriptors. Smartswitch # show trafficdescriptor...

  • Page 61

    Smartswitch 9a100 user guide 4-19 switch administration traffic management a user-defined pvc must have user-defined traffic descriptors. For instance, if a video link over a pvc requires a constant data flow of 5000 kb/s and a peak cell rate of 8000 kb/s, create a traffic descriptor for cbr traffic...

  • Page 62

    4-20 smartswitch 9a100 user guide traffic management switch administration use the command show caceqbwallocscheme to view the current cac policies used by each port for each qos and referenced by vpi . Smartswitch # show caceqbwallocscheme portid(all) : vpi(0) : ====================================...

  • Page 63

    Smartswitch 9a100 user guide 4-21 switch administration traffic management for example, enter the show porttrafficcongestion command to view current buffer utilization. Smartswitch # show porttrafficcongestion portnumber(all) : port id queue 1 queue 2 queue 3 queue 4 min max min max min max min max ...

  • Page 64

    4-22 smartswitch 9a100 user guide traffic management switch administration quality of service queue allocation guidelines the following values are recommended settings for the min and max thresholds for the qos queues under specific sustained traffic conditions. Use the settings in table 4-3 as guid...

  • Page 65

    Smartswitch 9a100 user guide 4-23 switch administration upgrading and changing software along with efci and backward rm cell marking, the smartswitch 9a100 uses standard rm cell marking. The switch discard threshold ( show switchtrafficcongestion ) corresponds to total shared buffer utilization and ...

  • Page 66

    4-24 smartswitch 9a100 user guide upgrading and changing software switch administration 4.7.2 boot load commands the following table describes the commands available from the boot load prompt, their use, and their associated parameters. Table 4-4 boot load commands command action parameters chpi cha...

  • Page 67

    Smartswitch 9a100 user guide 4-25 switch administration upgrading and changing software figure 4-4 memory locations affected by the boot load commands 4.7.3 upgrading boot load software two images of the boot load software reside in flash ram. The two images are identified as boot load image 0 and b...

  • Page 68

    4-26 smartswitch 9a100 user guide upgrading and changing software switch administration 5. Set up the tftp/bootp server tables (or equivalent file) with: - smartswitch 9a100 mac address - ip address of the smartswitch 9a100 ethernet interface - path to the image file on the tftp/bootp server 6. From...

  • Page 69

    Smartswitch 9a100 user guide 4-27 switch administration upgrading and changing software changing the default boot load image continuing with the example above, perform the following steps to set boot load image 0 back to being the default. 1. Reboot the smartswitch 9a100. 2. When the following messa...

  • Page 70

    4-28 smartswitch 9a100 user guide upgrading and changing software switch administration ............................................................................ ............................................................................ .............................................................

  • Page 71

    Smartswitch 9a100 user guide 4-29 switch administration upgrading and changing software ........................................................................... ................................................... Validity checks of the switch software downloaded file... All validity checks ok pro...

  • Page 72

    4-30 smartswitch 9a100 user guide saving core dumps switch administration if the problem is corrected, enter the update firmware command to continue with the upgrade process. However, if you are unable to correct the problem, use the df (download flash) command and a tftp/bootp server to replace the...

  • Page 73

    Smartswitch 9a100 user guide 4-31 switch administration saving core dumps enter the set coredump command to enable the core dump feature. For example, smartswitch # set coredump enablecoredump(n) : y serverip() : 204.95.77.240 coredumpfile() : /tftpboot/bobr/core username() : bobr userpassword() : s...

  • Page 74

    4-32 smartswitch 9a100 user guide saving core dumps switch administration if a system failure occurs while the core dump feature is enabled, the smartswitch 9a100 console appears similar to the example below. The smartswitch 9a100 then begins sending images of its memory to the core dump files on th...

  • Page 75

    Smartswitch 9a100 user guide 5-1 5 troubleshooting this chapter provides basic troubleshooting for diagnosing and fixing problems with vlan, emulated lans, and atm traffic congestion. 5.1 troubleshooting ip over atm you have configured an ip over atm vlan, but your network applications are not worki...

  • Page 76

    5-2 smartswitch 9a100 user guide troubleshooting lan emulation troubleshooting 4. Check ilmi, uni routes, and pvcs (if applicable). • if using svcs, use show atmroute to check whether static uni routes are correct and whether dynamic uni routes are established and correct. If dynamic routes are inco...

  • Page 77

    Smartswitch 9a100 user guide 5-3 troubleshooting troubleshooting pnni links 5. Check whether bus is connected. • use show busclient to check whether devices are registered with the bus. If clients are registered, check end node configuration. If not registered, check multi-point signaling. • use set...

  • Page 78

    5-4 smartswitch 9a100 user guide troubleshooting congestion troubleshooting 5.4 troubleshooting congestion if the bandwidth of your smartswitch 9a100 begins to decrease, and if connections are being lost or packets are being dropped at a high rate, it’s possible that your switch is becoming congeste...

  • Page 79

    Smartswitch 9a100 user guide 5-5 troubleshooting troubleshooting congestion 8. Is the number of cells being dropped by all other ports decreasing somewhat? • if no, go back to step 6. • if yes, continue. 9. Enter the set caceqbwallocscheme command and set call admission control for this port to a mo...

  • Page 80

    5-6 smartswitch 9a100 user guide troubleshooting congestion troubleshooting.

  • Page 81

    Smartswitch 9a100 user guide a-1 appendix a specifications this appendix describes the smartswitch 9a100 switch hardware, product features, technical specifications, and adapter pin-out descriptions. "•s )832:˜6"2'/ this section describes the hardware components of the smartswitch 9a100 atm switch. ...

  • Page 82

    A-2 smartswitch 9a100 user guide front panel specifications figure a-1 illustrates the front panel of the smartswitch 9a100 switch. Figure a-1 smartswitch 9a100 front panel no sync data no sync d ata console terminal (rj-45) ethernet port (10base-t) fail status power rx data tx data reset button eje...

  • Page 83

    Smartswitch 9a100 user guide a-3 specifications technical specifications "•¢ :'%+2,%"/˜96'%,),%":,329 table a-2 hardware specifications specification value processor i960cf, 33 mhz switching engine 2.5 gbps, non-blocking max i/o ports 45 for 6-slot chassis; 105 for 14-slot chassis switch latency 10 ...

  • Page 84

    A-4 smartswitch 9a100 user guide technical specifications specifications table a-4 atm port specifications media port speed framing connector max. Tx power min. Tx power max. Rx power min. Rx power range smf-ir 155 mbps or 622 mbps sts-3 or stm-1 sts-12 or stm-4 sc -8 dbm -15 dbm -7 dbm -28 dbm 15 k...

  • Page 85

    Smartswitch 9a100 user guide a-5 specifications technical specifications table a-6 management standards and specifications management protocol supported mibs snmpv1/snmpv2c mib ii (rfc 1213) interface table mib (rfc 1573) atom mib (rfc 1695) atom2 mib (pre-standard) lane mib (atm forum) ilmi 4.0 mib...

  • Page 86

    A-6 smartswitch 9a100 user guide technical specifications specifications.

  • Page 87

    Smartswitch 9a100 user guide b-1 appendix b agent support this appendix briefly describes the support provided for managing the smartswitch 9a100 using simple network management protocol (snmp). B.1 mib, smi, mib files and internet mib hierarchy a mib (management information base) is the term used t...

  • Page 88

    B-2 smartswitch 9a100 user guide mib, smi, mib files and internet mib hierarchy agent support figure b-1 internet mib hierarchy b.1.1 zeitnet cabletron proprietary mibs the location of some of zeitnet proprietary mibs in the internet hierarchy is shown in figure b-2. All nodes starting with “zn” rep...

  • Page 89

    Smartswitch 9a100 user guide b-3 agent support mib, smi, mib files and internet mib hierarchy . Figure b-2 zeitnet private mibs in figure b-2, the zeitnet proprietary group is identified by 1.3.6.1.4.1.1295; its subgroup, called znproducts, is identified by 1; and the first variable is znmanagedobje...

  • Page 90

    B-4 smartswitch 9a100 user guide mib, smi, mib files and internet mib hierarchy agent support : figure b-3 zeitnet cabletron smartswitch 9a100 mib object identifier example b.1.3 supported protocols the smartswitch 9a100 supports simple network management protocol (snmp). Both the snmpv1 and snmpv2c...

  • Page 91

    Smartswitch 9a100 user guide b-5 agent support mib, smi, mib files and internet mib hierarchy b.1.5 zeitnet cabletron proprietary mib groups the following table of zeitnet proprietary mib groups lists group name, object identifier, and group function. Table b-1 zeitnet proprietary mib groupings name...

  • Page 92

    B-6 smartswitch 9a100 user guide mib, smi, mib files and internet mib hierarchy agent support b.1.6 smartswitch 9a100 mib support the smartswitch 9a100 is shipped with the following mibs: • mib ii (rfc 1213) • interface table mib (rfc 1573) • atom mib (rfc 1695) • atom2 mib (pre-standard) • lane mib...

  • Page 93

    Smartswitch 9a100 user guide b-7 agent support managing the smartswitch 9a100 not supported the following mib objects are not supported. If used, these objects return either the value zero or the message, “not supported.” • atminterfacemaxvpcs • atminterfaceconfvpcs • atminterfaceds3plcptable • atmi...

  • Page 94

    B-8 smartswitch 9a100 user guide managing the smartswitch 9a100 agent support b.2.1 console commands that affect the agent the following is a list of the console commands that affect the operation of the smartswitch 9a100 snmp agent. For detailed descriptions of these commands, see the smartcell 6a0...

  • Page 95

    Smartswitch 9a100 user guide c-1 appendix c technical support this appendix tells you what to do if you need technical support for your smartswitch 9a100 switch. Cabletron offers several support and service programs that provide high-quality support to our customers. For technical support, first con...

  • Page 96

    C-2 smartswitch 9a100 user guide hardware warranty technical support • detailed description of the issue (including history, what you've tried, and conditions under which you see this occur) • 6>À`Ý>ÀiÊ“œ`i•Ê˜Ö“liÀ]ÊÃœvÍÝ>ÀiÊÜiÀÈœ˜]Ê>˜`ÊÃ݈Ív…Êvœ˜vˆ}ÖÀ>͈œ˜Ê-Í…>ÍʈÃ]ÊÝ…>ÍÊ«>ÀÍÊÍß«iÃÊ>Àiʈ˜ÊÝ…>ÍÊ Ã•...

  • Page 97

    Smartswitch 9a100 user guide d-1 appendix d acronyms a b aal atm adaptation layer aal1 atm adaptation layer type 1 aal2 atm adapter layer type 2 aal3/4 atm adapter layer type 3/4 aal5 atm adapter layer type 5 aalm atm adaptation layer mux abr available bit rate afi authority and format identifier an...

  • Page 98

    D-2 smartswitch 9a100 user guide acronyms c bootp boot protocol bus broadcast and unknown server cac call admission control can campus area network cat-3 category 3 unshielded twisted pair cable cat-5 category 5 unshielded twisted pair cable cbr constant bit rate ccitt comite consultatif internation...

  • Page 99

    Smartswitch 9a100 user guide d-3 acronyms d e dcc digital cross connect, generic dacs or direct connect card, data interface module df download flash ds-0 digital signaling 0 ds-1 digital signaling 1 ds-3 digital signaling 3 dte data terminal equipment dtl designated transit list dvt delay variation...

  • Page 100

    D-4 smartswitch 9a100 user guide acronyms f g h i fcs frame check sequence fifo first in first out ftp file transfer protocol gb/s gigabits per second gcac generic call admission control gcra generic cell rate algorithm gfc generic flow control hec header error check ieee institute of electrical and...

  • Page 101

    Smartswitch 9a100 user guide d-5 acronyms j k l ilmi integrated local management interface i/o input/output iom input/output module ip internet protocol ip/atm internet protocol over atm ipx internetwork packet exchange protocol itu-tss international telecommunications union-telecommunications stand...

  • Page 102

    D-6 smartswitch 9a100 user guide acronyms m n lecsela n lan emulation configuration server emulated lan les lane server leselan lane server emulated lan lis logical ip subnetwork llc logical link control lmi local management interface mac media access control man metropolitan area network mb/s megab...

  • Page 103

    Smartswitch 9a100 user guide d-7 acronyms o p netbeui netbios extension user interface nfs network file system nic network interface controller/card nls natural language syntax nms network management system nni network node interface or network-to-network interface nrt-vbr non real time - variable b...

  • Page 104

    D-8 smartswitch 9a100 user guide acronyms q r pdu protocol data unit pgl peer group leader pmd physical media dependent sub-layer pmp point-to-multipoint p-nni private network node interface or private network-to-network interface ppd partial packet discard prom programmable read-only memory pti pay...

  • Page 105

    Smartswitch 9a100 user guide d-9 acronyms s rm resource management rma return merchandise authorization rqu receive queue underrun rs-# recommended standard defined by electronic industries association rt-vbr real time - variable bit rate rw read-write access saal signaling atm adaptation layer sar ...

  • Page 106

    D-10 smartswitch 9a100 user guide acronyms t u svc switched virtual circuit svcc switched virtual channel connection t-1 transmission system 1 t-3 transmission system 3 taxi transparent asynchronous transmitter/receiver interface tcp transmission control protocol td traffic descriptor tdm time-divis...

  • Page 107

    Smartswitch 9a100 user guide d-11 acronyms v w vbr/rt variable bit rate/real time vbr/nrt variable bit rate/non-real time vc virtual circuit vcc virtual channel connection vci virtual channel identifier vcl virtual channel link vlan virtual lan vp virtual path vpc virtual path connection vpi virtual...

  • Page 108

    D-12 smartswitch 9a100 user guide acronyms.

  • Page 109

    Smartswitch 9a100 user guide i-1 index numerics 6a-iom-21-4 ........................................... 2-3 6a-iom-22-4 ........................................... 2-3 6a-iom-29-4 ........................................... 2-3 6a-iom-29-4-ir ...................................... 2-3 6a-iom-29-4-lr...

  • Page 110

    I-2 smartswitch 9a100 user guide index affecting the agent ............................. B-8 alias .................................................... 2-9 create .................................................. 2-9 delete .................................................. 2-9 display ...............

  • Page 111

    Smartswitch 9a100 user guide i-3 index g go ............................................................ 4-24 h hardware specifications ........................... A-3 hardware warranty ................................... C-2 he ............................................................ 4-24 help ...

  • Page 112

    I-4 smartswitch 9a100 user guide index p parallel routes ........................................... 4-7 partial commands ................................... 2-11 pc serial port adapter pin-out .................. A-5 peak cell rate ........................................... 4-17 physical specificat...

  • Page 113

    Smartswitch 9a100 user guide i-5 index atm ports ........................................ A-4 front panel ......................................... A-1 management standards ...................... A-5 physical ............................................. A-3 protocols standards ........................

  • Page 114

    I-6 smartswitch 9a100 user guide index vpi non-zero values ................................ 4-15 vpi bits ................................................... 4-15 vpi/vci pairs ......................................... 4-15 z zeitnet cabletron proprietary mibs ....... B-2.