Cabletron Systems SWPIM-DDS Installation Manual

Manual is about: Sliding WAN Physical Interface Module

Summary of SWPIM-DDS

  • Page 1

    Swpim-dds lnk sts title page swpim-dds installation guide 9033036-01.

  • Page 3: Notice

    Swpim-dds installation guide i notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardw...

  • Page 4

    Notice ii swpim-dds installation guide industry canada notice this digital apparatus does not exceed the class a limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the canadian department of communications. Le présent appareil numérique n’émet pa...

  • Page 5

    Notice swpim-dds installation guide iii cabletron systems, inc. Program license agreement important: this license applies for use of product in the following geographical regions: canada mexico central america south america before opening or utilizing the enclosed product, carefully read this licens...

  • Page 6

    Notice iv swpim-dds installation guide if the program is exported from the united states pursuant to the license exception tsr under the u.S. Export administration regulations, in addition to the restriction on transfer set forth in sections 1 or 2 of this agreement, you agree not to (i) reexport or...

  • Page 7

    Notice swpim-dds installation guide v cabletron systems sales and service, inc. Program license agreement important: this license applies for use of product in the united states of america and by united states of america government end users. Before opening or utilizing the enclosed product, careful...

  • Page 8

    Notice vi swpim-dds installation guide if the program is exported from the united states pursuant to the license exception tsr under the u.S. Export administration regulations, in addition to the restriction on transfer set forth in sections 1 or 2 of this agreement, you agree not to (i) reexport or...

  • Page 9

    Notice swpim-dds installation guide vii cabletron systems limited program license agreement important: this license applies for the use of the product in the following geographical regions: europe middle east africa asia australia pacific rim before opening or utilizing the enclosed product, careful...

  • Page 10

    Notice viii swpim-dds installation guide if the program is exported from the united states pursuant to the license exception tsr under the u.S. Export administration regulations, in addition to the restriction on transfer set forth in sections 1 or 2 of this agreement, you agree not to (i) reexport ...

  • Page 11

    Notice swpim-dds installation guide ix declaration of conformity application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european repre...

  • Page 12

    Notice x swpim-dds installation guide.

  • Page 13: Contents

    Swpim-dds installation guide xi contents introduction using this guide .......................................................................... Xiii structure of this guide................................................................. Xiii swpim-dds features .......................................

  • Page 14

    Contents xii swpim-dds installation guide.

  • Page 15: Introduction

    Swpim-dds installation guide xiii introduction welcome to the cabletron systems swpim-dds installation guide . This manual gives an introduction to the swpim-dds, lists features and capabilities, details the cabling pinouts, and explains how to install the swpim-dds. The swpim-dds (sliding wan physi...

  • Page 16: Specifications

    Introduction xiv swpim-dds installation guide appendix a , specifications , contains information on functionality and operating specifications, connector pinouts for the swpim-dds, environmental requirements, and physical properties. Swpim-dds features interfaces the swpim-dds can be installed into ...

  • Page 17: Theory of Operation

    Introduction swpim-dds installation guide xv theory of operation the dds interface consists of the following: framer/transceiver and line isolation/protection. Dds framer/transceiver the swpim-dds provides the framing and transceiver functionality for dds-pri and dds-cc (clear channel). Dds-pri - dd...

  • Page 18: Related Manuals

    Introduction xvi swpim-dds installation guide related manuals the following cabletron systems manuals may help the user to set up and manage the swpim-dds: ssr-600 installation guide hsim-ssr-600 installation guide 6c105 smartswitch 6000 overview and setup guide ethernet technology guide cabling gui...

  • Page 19: Document Conventions

    Introduction swpim-dds installation guide xvii document conventions the following conventions may be used in this document: note note symbol. Calls the reader’s attention to any item of information that may be of special importance. Tip tip symbol. Conveys helpful hints concerning procedures or acti...

  • Page 20: Getting Help

    Introduction xviii swpim-dds installation guide getting help for additional support related to this device or document, contact cabletron systems using one of the following methods: before calling cabletron systems, have the following information ready: • your cabletron systems service contract numb...

  • Page 21: Chapter 1

    Swpim-dds installation guide 1-1 chapter 1 installation this chapter covers the following items: • unpacking the swpim-dds ( section 1.1 ) • installing the swpim-dds into the host platform ( section 1.2 ) • a description of the lanview led indications ( section 1.3 ) • connecting the swpim-dds to th...

  • Page 22: 1.2

    Chapter 1: installation 1-2 swpim-dds installation guide 1.2 installing the swpim-dds the swpim-dds can be installed in any available open slot in the host platform. To install the swpim-dds, proceed as follows: 1. The host platform may be powered down, if desired. Be aware of loss of desired parame...

  • Page 23

    Installing the swpim-dds swpim-dds installation guide 1-3 figure 1-1 installing the swpim-dds into the host platform 7. Install the swpim-dds in the host platform by aligning the swpim-dds with the rail guides in the host platform and sliding it in. Take care that the swpim-dds slides in straight an...

  • Page 24: 10.

    Chapter 1: installation 1-4 swpim-dds installation guide 10. The swpim-dds must be configured before the wan connection is made. Once the swpim-dds has been configured, the host platform must undergo a soft or hard restart in order for the swpim-dds to be recognized and for traffic to pass. Refer to...

  • Page 25: 1.4

    Connecting to the network swpim-dds installation guide 1-5 1.4 connecting to the network figure 1-2 depicts a typical configuration for the swpim-dds. Cabletron systems part number for the cable is 9360119-x, where x represents the length of the cable. Figure 1-2 typical configuration 1.5 completing...

  • Page 26

    Chapter 1: installation 1-6 swpim-dds installation guide.

  • Page 27: Appendix A

    Swpim-dds installation guide a-1 appendix a specifications this section describes the environmental specifications and safety and approval requirements for the swpim-dds. Cabletron systems reserves the right to change these specifications at any time without notice. A.1 physical properties a.2 netwo...

  • Page 28: A.2.1

    Appendix a: specifications a-2 swpim-dds installation guide a.2.1 recommended wan cable cabletron systems part number for the dds line interface cable: 9360119-x (where x is the desired length of the cable) a.3 environmental requirements table a-1 rj48 pinouts pin signal 1 transmit ring 2 transmit t...

  • Page 29: A.4

    Regulatory compliance swpim-dds installation guide a-3 a.4 regulatory compliance safety ul 1950 (without d3 deviations), csa c22.2 no. 950, and en 60950 emi fcc part 15 class a, en 55022 class a and vcci v-3 electromagnetic compatibility (emc) en 50082-1 including: iec 801-2 (esd), iec 801-3 (radiat...

  • Page 30

    Appendix a: specifications a-4 swpim-dds installation guide.