CableTronix CTA-30RK-1000 Installation Manual

Summary of CTA-30RK-1000

  • Page 1

    Installation manual cta-30rk-1000 rack mount distribution amplifier 1.

  • Page 2

    Package contents this package contains: one cta-30rk-1000 rack mount distribution amplifier one cta-30rk-1000 installation manual product description the cta-30rk-1000 is a rack mount push-pull amplifier producing signals with extremely low distortion and harmonic content. The unit is capable of 135...

  • Page 3

    Installation and operation note to system installer system installer must adhere to article 820-40 of the nec that provides guidelines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practica...

  • Page 4

    4. Hardware connections a. The cta-30rk-1000 is designed for installation in a standard 19” eia rack. B. Connect a 75ohm coaxial cable with f-connectors from the headend combiner output to cta-30rk-1000’s in port. Do not exceed the unit’s maximum input level. C. Connect a 75ohm coaxial cable with f-...

  • Page 5

    Installed in this amplifier to compensate for this slope in cable resulting in a flat frequency response at the output 8. Troubleshooting a. Ensure you are using quality multiple shielded cables with quality radial or compression f-connectors. B. Ensure the f-connector’s center conductor is making s...