CADDX Ranger 8000 Installation Manual

Other manuals for Ranger 8000: Operator's Manual, Operator's Manual
Manual is about: DOWNLOADABLE CONTROL COMMUNICATOR

Summary of Ranger 8000

  • Page 1

    5 5 $ $ 1 1 * * ( ( 5 5 ( ( d d o o w w n n l l o o a a d d a a b b l l e e c c o o n n t t r r o o l l c c o o m m m m u u n n i i c c a a t t o o r r i i n n s s t t a a l l l l a a t t i i o o n n m m a a n n u u a a l l table of contents general description..........................................

  • Page 2

    2 general description the caddx ranger 8600e is a versatile 6-zone up/downloadable security control with a built-in digital communicator. Its microcomputer design gives some of the most versatile, yet easy to use features available for most security applications today. Each of the six zones can be p...

  • Page 3

    3 feature definitions alarm history five seconds after pressing the [0] key, the keypad will annunciate “freeze frame” alarm history. The zone led’s will indicate which zone(s) caused the last alarm, regardless of the number of times the ranger 8600e has been armed or disarmed since that alarm. It a...

  • Page 4

    4 secondary exit delay used most often for garage doors, this zone type is a second entry/exit delay that has its own delay times, independent of the standard entry/exit delay zone. Telephone line monitor the ranger 8600e has a telephone line monitor that monitors the voltage and current of the tele...

  • Page 5

    5 terminal drawing & special notes.

  • Page 6

    6 terminal description terminal description 4- pin connector programmable auxiliary output terminals 1 connect one side of zone 1 loop. The other side of loop to common terminal 2. Open or short causes alarm. 2 common (-) terminal 3 connect one side of zone 2 loop. The other side of loop to common t...

  • Page 7

    7 how to program the ranger 8600e the ranger 8600e can be placed into the "program" mode by either of the following methods. Enter the 4 digit "go to program" access code (locations 28-31). At initial power-up the code in these slots is [9][7][1][3]. The ranger 8600e must be disarmed to gain access ...

  • Page 8

    8.

  • Page 9

    9 programming phone numbers and formats (required programming for central station reporting) this section describes all the locations that must be programmed for the ranger 8600e to function and report to a central station. Other programming can be found in the section “programming instructions” sta...

  • Page 10

    10 table 1.1 data format description "0" local only the communicator is disabled "1" universal 4 + 2 1800hz transmit 2300hz handshake double round parity 20 pps. "2" ademco/silent knight fast 1900hz transmit 1400hz handshake double round parity 20 pps. "3" caddx modem proprietary "4" reserved reserv...

  • Page 11

    11 locations 028-031: programming the "go to program" access code locations 028-031contain the "go to program" access code. Location 028 contains the first digit of the code and location 031 contains the fourth digit of the code. The code must contain four (4) digits. With the ranger 8600e disarmed,...

  • Page 12

    12 note: when programming the following communicator codes, a "10" must be programmed in order to report a zero (0). Location 086-087: programming the ranger 8600e for duress code capability the ranger 8600e has the ability to report a duress code when the system is armed or disarmed with user code ...

  • Page 13

    13 location 100-101: programming to report failure to communicate the 8600e has the ability to communicate each time communication is re-established after a signal has been unable to report. The data that failed to communicate will not be sent, but can be recovered from the log. The desired "failure...

  • Page 14

    14 location 120-121: programming to report ac power loss the ranger 8600e has the ability to report an ac power failure code when ac power is lost. This report can be immediate or delayed depending on the information programmed in location 150 ac power loss delay. The desired ac failure mode should ...

  • Page 15

    15.

  • Page 16

    16 location 131: automatic bypass / instant arming location 131 is used to enable automatic "instant arming". Programming a "1" in this location will cause the control to automatically enter the "instant" mode and bypass interior follower zones if a fault is not detected on an entry/exit zone during...

  • Page 17

    17 location 140: priority siren cutoff inhibit location 140 can be programmed based on the following selections. Value description 1 a priority zone type siren will sound continuously until an arm/disarm code is entered (otherwise, the siren will time-out as programmed in location 77). This location...

  • Page 18

    18 table 2.1 data activation on notes "0" burglary alarm momentary output * "1" fire alarm momentary output * "2" panic alarm / duress momentary output * "3" armed state latched output "4" armed with bypass latched output "5" ac power latched output "6" low battery latched output "7" line seizure / ...

  • Page 19

    19 location 152: programming the number of days left until autotest report location 152 contains the number of days left until the next autotest report. If this location contains a "0", an autotest signal will be reported the first time the current time equals the autotest time programmed in locatio...

  • Page 20

    20 location 164: programming the autotest time, minutes - tens digit location 164 contains the tens digit, of the minutes after the hour that the autotest is desired. The time is entered in 24- hour time. If the desired autotest time is 5:25 pm, the 24-hour time is 17:25, so this location should con...

  • Page 21

    21 table 3.1 zones to program for n/c operation data t0 program in location 174 6 "1" 5 "2" 5 & 6 "3" 4 "4" 4 & 6 "5" 4 & 5 "6" 4, 5, & 6 "7" 3 "8" 3 & 6 "9" 3 & 5 a ="10" 3, 5, & 6 b ="11" 3 & 4 c ="12" 3, 4, & 6 d ="13" 3, 4, & 5 e ="14" 3, 4, 5, & 6 f ="15" location 175: programming zones 1 & 2 f...

  • Page 22

    22 location 177: split reporting - programming ac power fail, low battery, open/close, and maintenance open/close to report to the secondary phone number the 8600e is capable sending certain reports to the secondary telephone number. This feature known as split reporting can be used to send alarm re...

  • Page 23

    23 location 182: format over-ride location the number selected in this location will select the format options as follows: value description 1 add for extended reporting 2 add for hex digits allowed 4 add for 20pps 8 add for 10pps location 183: format over-ride location the number selected in this l...

  • Page 24

    24 location 197: force arming force arming is a feature that will allow the ranger 8600e to be armed without all zones secure (no "ready" led illuminated). At the end of the exit delay, all unsecured zones will automatically bypass, while all secure (ready) zones will be armed and active in the syst...

  • Page 25

    25 reports to send to both phone numbers data for location 205 maintenance code open/close "1" open/close "2" open/close; maintenance code open/close "3" low battery "4" low battery; maintenance code open/close "5" low battery; open/close "6" low battery; open/close; maintenance code open/close "7" ...

  • Page 26

    26 location 210: programming to report exit error the ranger 8600e has the ability to report an exit error code if an entry/exit zone is violated at the moment the exit delay expires. The desired exit error code is programmed in location 210. If this location contains a "0", exit errors will not be ...

  • Page 27

    27 location 250-251: reserved location 252-253: programming to report keypad auxiliary 3 the ranger 8600e has the ability to report a silent auxiliary 3 code each time the [7] and [9] keys are pressed simultaneously on the keypad. The desired auxiliary 3 code is programmed in locations 252-253. If b...

  • Page 28

    28 arm/disarm codes 1 - 7 location page description data 1 data 2 data 3 data 4 default 000-003 10 user #1 arm / disarm code "1-2-3-4" 004-007 10 user #2 arm / disarm code "15" disabled 008-011 10 user #3 arm / disarm code "15" disabled 012-015 10 user #4 arm / disarm code "15" disabled 016-019 10 u...

  • Page 29

    29 location page description zone id event/ext code default 122-123 14 low battery communicator code "0" disabled 124 14 trouble communicator code zone number "0" disabled 125 14 zone bypass communicator code zone number "0" disabled 126 14 restore communicator code zone number "0" disabled 127 14 c...

  • Page 30

    30 location page description data default 174 20 program zones 3 thru 6 for normally closed operation "0" supervised 175 21 program zones 1 & 2 for normally closed operation "0" supervised 176 21 split report - tamper, download complete, & autotest "0" phone #1 177 22 split report - ac failure, low ...

  • Page 31

    31 location page description data default 250 27 reserved reserved 251 27 reserved reserved 252 27 auxiliary 3 communicator code "0" 253 27 auxiliary 3 extended communicator code "0" 254 27 user on site communicator code "0" 255 27 cross zoning time (minutes) "5" remember! After all data has been en...

  • Page 32

    32 appendix 1 - reporting in sia format the 8600e has the ability to report sia level 1 transmissions to either or both phone numbers. Each report in sia consists of an event code and a zone or user id. The zone or user id is programmed in the first digit of each report. When programming the event c...

  • Page 33

    33 appendix 2 - reporting in contact id the 8600e has the ability to report ademco contact id transmissions to either or both phone numbers. Each report in contact id consists of an event code and a zone or user id. The zone or user id is programmed in the first digit of each report. When programmin...

  • Page 34

    34 local telephone company interface information telephone connection requirements except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and standard telephone company provided jacks or equivalent in such a manner as to allow for...

  • Page 35

    Specifications operating power 16.5 vac 25 va transformer auxiliary power 12 vdc 500ma (400ma for ul) loop resistance 300 ohms maximum built-in siren driver 2-tone (steady and yelp) loop response selectable to 500ms operating temperature 32 to 120 degrees f keypad dimensions 5.50" wide 4.25" high .8...