2 aquos - ibis - idron en summary 1 introduction ................................................4 1.1 dear customer ..........................................4 1.2 revisions to the publication .................4 1.3 care of the manual and how to consult it .............................................
3 aquos - ibis - idron en 14.7 electrical safety ...................................42 14.8 smoke fan ................................................42 14.9 gear motor ............................................42 14.10 temporary power cut .......................42 14.11 failed start-up .............
4 aquos - ibis - idron en 1 introduction 1.1 dear customer thank you for having chosen our product. To allow for optimal operation and for you to enjoy the warmth and sense of wellbeing that the fire can convey in your home, we advise you to read this manual carefully before starting up the product ...
5 aquos - ibis - idron en and/or poor operation. • do not use the product as a ladder or supporting structure. • do not place laundry on the product to dry. Any clothes horses or similar objects must be kept at a safe distance from the product. • fire hazard. • all liability for improper use of the ...
6 aquos - ibis - idron en 2.4 spare parts only use original spare parts. The retailer or service centre can provide all the useful information regarding spare parts. It is recommended not to wait for the parts to be worn before having them replaced. It is important to perform regular maintenance. 3 ...
7 aquos - ibis - idron en the hearth. • variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural characteristics of the material and product use. • masonry work. • plant parts (if present) not supplied by the manufacturer. Any technical intervention...
8 aquos - ibis - idron en • content: 100% untreated wood with no added binding agents (max percentage of bark: 5%). • packaging: in bags made from environmentally friendly or biologically decomposable material. The company strongly recommends using certified fuel for its products (dinplus, Ö-norm m7...
9 aquos - ibis - idron en if the floor is made of wood, it is recommended to place a floor protection in accordance with the standards in force in the country of installation. Fig. 2 - distances to follow type non-flammable walls flammable walls aquos 15-22-22 h2o a = 5 cm / b = 5 cm a = 10 cm / b =...
10 aquos - ibis - idron en fig. 3 - pellet stove installation example 5.6 connections connection to the flue pipe connection to an external duct with an insulated or double-wall pipe connection to the flue pipe the internal dimensions of the chimney pipe must not exceed 20x20 cm or 20 cm in diameter...
11 aquos - ibis - idron en legend 1 windproof 2 flue 3 inspection use adequate instruments to verify that there is a minimum draught of 5 pa. Set-up an inspection hole at the bottom of the chimney to perform periodic checks and cleaning, which must be done annually. The connection to the chimney mus...
12 aquos - ibis - idron en fig. 5 - wind influence 6 technical drawings and characteristics 6.1 dimensions fig. 6 - aquos 15 - aquos 22 - aquos 22 h2o dimensions.
13 aquos - ibis - idron en fig. 7 - ibis 11 dimensions.
14 aquos - ibis - idron en fig. 8 - ibis 15 - ibis 22 - ibis 22 h2o dimensions.
15 aquos - ibis - idron en fig. 9 - idron 11 dimensions.
16 aquos - ibis - idron en fig. 10 - idron 15 - idron 22 - idron 22 h2o dimensions.
17 aquos - ibis - idron en technical characteri- stics aquos 15 aquos 22 (max) total thermal power: 15,4 kw (13244 kcal/h) / 13 kw (11180 kcal/h) 21 kw (18060 kcal/h) / 17 kw (14620 kcal/h) (max) total thermal power: 4,4 kw (3784 kcal/h) / 3 kw (2580 kcal/h) 4,4 kw (3784 kcal/h) / 3 kw (2580 kcal/h)...
18 aquos - ibis - idron en technical characteri- stics ibis 11 ibis 15 ibis 22 - ibis 22 h2o (max) total thermal power: 11,6 kw (9976 kcal/h) / 10 kw (8600 kcal/h) 15,4 kw (13244 kcal/h) / 13 kw (11180 kcal/h) 21 kw (18060 kcal/h) / 17 kw (14620 kcal/h) (max) total thermal power: 3,6 kw (3096 kcal/h...
19 aquos - ibis - idron en technical characteri- stics idron 11 idron 15 idron 22 - idron 22 h2o (max) total thermal power: 11,6 kw (9976 kcal/h) / 10 kw (8600 kcal/h) 15,4 kw (13244 kcal/h) / 13 kw (11180 kcal/h) 21 kw (18060 kcal/h) / 17 kw (14620 kcal/h) (max) total thermal power: 3,6 kw (3096 kc...
20 aquos - ibis - idron en • one contains the ceramics (fig. 12 page 20). In this case there will be a single pack for the structure (the box with the ceramics will be placed on top of the pack with the structure). Fig. 11 - example of stove + steel sides packaging fig. 12 - example of ceramics pack...
21 aquos - ibis - idron en if the stove smoke outlet is forced or used improperly to lift it or position it, the operation of the stove can be damaged irreparably. Fig. 14 - 1. Turn the feet clockwise to lower the stove - 2. Turn the feet counterclockwise to raise the stove 7.2 ceramic and metal sid...
22 aquos - ibis - idron en 7.3 metal sides insertion (idron) remove, on the upper part, the metal top (a). Take the side panel (b) and fix it to the stove: slide the side hole into the screw fixed on the stove (c). Repeat the same operation for both sides. Reposition the metal top (a). Fig. 16 - met...
23 aquos - ibis - idron en 8 plumbing connection 8.1 plumbing system connection important! If installation of the product involves interaction with another, pre-existing system complete with heating equipment (gas boiler, methane boiler, diesel boiler, etc.), contact qualified personnel, who subsequ...
24 aquos - ibis - idron en production (aquos 22 h2o / ibis 22 h2o / idron 22 h2o) fig. 19 - plumbing connection legend a1 3/4”m heating water delivery a2 3/4”m heating water return 3/4”m c 3 bar 1/2” m safety valve e 1/2”f system emptying b1 domestic hot water delivery b2 domestic hot water return 8...
25 aquos - ibis - idron en it is strongly recommended to wash the entire system before connecting the stove in order to get rid of residues and deposits. Upstream from the stove, always install gate valves so as to disconnect it from the plumbing system should it be necessary to move it, or when it ...
26 aquos - ibis - idron en 8.7 domestic hot water production kit (aquos 22 h2o / ibis 22 h2o / idron 22 h2o stoves only) the aquos 22 h2o, ibis 22 h2o and idron 22 h2o stoves are equipped with a complete kit for the production of domestic water made up of: • plate heat exchanger • a 3-way diverter v...
27 aquos - ibis - idron en if you have very extensive systems (with a large amount of water) or which require frequent refilling, the installation of water softening systems. It should be remembered that incrustations drastically reduce performance due to their extremely low thermal conductivity. 9 ...
28 aquos - ibis - idron en 10 initial start-up 10.1 general precautions remove all components that could burn from the brazier and glass (manual, various adhesive labels and any polystyrene). Check that the brazier is positioned correctly and rests properly on the base. Fig. 26 - check the brazier a...
29 aquos - ibis - idron en do not expect heating efficiency immediately!!! 10.2 opening/closing the door attention! The door must be closed properly for the boiler to work correctly. Use suitable protective clothing (such as gloves) to open the boiler door. 10.3 settings to be carried out before the...
30 aquos - ibis - idron en fig. 28 - display legend 1 boiler lighting/shutdown 2 scrolling of programming menu to decrease. 3 menu 4 scrolling of programming menu to increase. 5 decrease set temperature/programming functions. 6 increase set temperature/programming functions. 7 display. 11.2 main men...
31 aquos - ibis - idron en m. Components test (displayed only when the boiler is switched off) n. “chimney sweep” function (activated only when the boiler is switched on, for field emissions test). O. System configuration. P. Season. Q. Technical menu. Note: some of the items listed above cannot be ...
32 aquos - ibis - idron en • press “menu” to confirm. • enter the minutes with the + - keys. • press “menu” to confirm and “esc” to exit. H - pump on t to select the pump on t function act as follows: • press the “menu” button. • scroll to “settings” using the arrows • press “menu” to confirm. • scr...
33 aquos - ibis - idron en • press “menu” to confirm. • select “on” with the + - keys (off by default) • press “menu” to confirm and “esc” to exit q - system configuration to change the system configuration act as follows: • press the “menu” button. • scroll to “settings” using the arrows • press “m...
34 aquos - ibis - idron en 12 preliminary notions 12.1 system configurations depending on the model upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the “settings” menu. The possible configurations are 5, as described below: configura...
35 aquos - ibis - idron en fig. 30 - configuration 2.1 (factory setting for version with domestic hot water - dhw) fig. 31 - configuration 2.2.
36 aquos - ibis - idron en fig. 32 - configuration 3 fig. 33 - configuration 4.
37 aquos - ibis - idron en fig. 34 - configuration 5 legend 1 stove 2 heating delivery 3 heating return 4 zone valves 5 heating bodies 6 hot domestic water 7 cold domestic water 8 domestic water boiler 9 diverter valve 10 boiler thermostat 11 thermostatic mixing valve 12 domestic water 10 kΩ β3434 n...
38 aquos - ibis - idron en fig. 35 - operating mode 13.2 external thermostat connection (e) external thermostat (not included with the boiler, to be provided by the user). The temperature of the boiler can also be controlled by an external room thermostat. It is located in a central position of the ...
39 aquos - ibis - idron en connect the cables from the external thermostat to points 1-2 of the terminal block on the boiler. Once the thermostat has been connected one must enable it. In order to do this, proceed as follows: • press the “menu” button. • scroll to “settings” using the arrows. • sele...
40 aquos - ibis - idron en 13.6 programming examples: p1 p2 on off day on off day 08:00 12:00 mon 11:00 14:00 mon boiler on from 08:00 to 14:00 on off day on off day 08:00 11:00 mon 11:00 14:00 mon boiler on from 08:00 to 14:00 on off day on off day 17:00 24:00 mon 00:00 06:00 tue boiler on from 17:...
41 aquos - ibis - idron en • enter menu • scroll to sleep with the arrows • press menu • with the + - keys adjust the desired shutdown time. The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (i can therefore delay the shutdown for up to ...
42 aquos - ibis - idron en 13.17 feed screw (see section d settings menu page 30) allows to fill the pellets loading system. It can only be activated with the boiler switched off, it displays an 180” countdown after which the feed screw stops automatically, as when exiting the menu. 13.18 components...
43 aquos - ibis - idron en 14.12 antifreeze function if the probe in the boiler detects a water temperature of less than 5°c, the circulation pump is automatically activated to prevent the system from freezing. 14.13 pump anti-seizure function if the pump is not used for prolonged periods, it is act...
44 aquos - ibis - idron en 14.15 alarm reset to reset the alarm one must press and hold key 1 (esc) for a few seconds. The boiler performs a check to determine if the cause of the alarm persists or not. In the first case the alarm will still be displayed, in the second case it will go onto off. If t...
45 aquos - ibis - idron en 15.1 daily or weekly cleaning performed by the user 15.2 before each start-up clean the ash and any deposits in the brazier that could clog the air passage holes. If the pellets in the hopper finish, unburned pellets may accumulate in the brazier. Always empty the residue ...
46 aquos - ibis - idron en fig. 39 - cleaning the internal pipe unit using scrapers (aquos 15-22-22 h2o / ibis 15-22-22 h2o / idron 15-22-22 h2o) fig. 40 - cleaning the lower drawer (ibis 11 / idron 11) 15.5 periodic cleaning performed by a qualified technician 15.6 cleaning the heat exchanger half-...
47 aquos - ibis - idron en 15.9 cleaning the lower compartment remove the ash drawer “g”, empty it and using the nozzle of a vacuum cleaner remove any ash and soot that may have built up under the drawer “g”. Remove the brazier “f” and clean it every 2/3 days. Remove the drawer “e”, empty it and usi...
48 aquos - ibis - idron en attention: it is advisable to clean the lower compartment “e” once a week and in any case according to the fuel consumption. Check the seal of the ceramic fibre gasket on the plug and replace it if necessary. Check the seal of the door gasket and replace it if necessary. A...
49 aquos - ibis - idron en attention: the frequency with which the smoke exhaust must be cleaned depends on the use of the stove and the type of installation. We recommend contacting an authorised service centre for end-of-season maintenance and cleaning as the abovementioned operations will be perf...
50 aquos - ibis - idron en 16 problems/causes/solutions 16.1 checking the internal components attention! The internal electromechanical components must only be checked by qualified personnel whose technical expertise includes combustion and electricity. It is recommended to perform this routine main...
51 aquos - ibis - idron en anomaly possible causes solutions the fire goes out or the appliance stops automatically. The pellet hopper is empty fill the hopper with pellets. The pellets are not fed see the previous anomaly. The pellet temperature safety probe has been triggered let the product cool ...
52 aquos - ibis - idron en anomaly possible causes solutions in the automatic position the stove always runs at full power. Thermostat is set to minimum. Set the thermostat temperature again. The room thermostat is in the maximum position. Set the thermostat temperature again. Faulty temperature pro...