    2 easy - sweet 3 en summary 1 manual simbology .........................................3 2 dear customer ................................................. 3 3 cautions ............................................................3 4 safety requirements ........................................4 5 war...

  • Page 3

    3 easy - sweet 3 en 1 manual simbology • the icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the user and/or the authorized technician and/or the specialized stove-repairer). • warning symbols indicates an important note. User authorised tec...

  • Page 4

    4 easy - sweet 3 en 4 safety requirements • installation, electrical connection, functional verification and maintenance must only be performed by qualified or authorised personnel. • live electrical parts: disconnect the product from the 230v power supply before performing any maintenance operation...

  • Page 5

    5 easy - sweet 3 en animals and for your safety please use appropriate fireproof devices, such as heat- protecting gloves. • if the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned, do not remove the hand rejector and do not touch the auger. Please contact the...

  • Page 6

    6 easy - sweet 3 en characteristics of the material and product use. • masonry work. • plant parts (if present) not supplied by the manufacturer. Any technical interventions on the product to eliminate the above-said defects and consequent damages must be agreed upon with the technical assistance ce...

  • Page 7

    7 easy - sweet 3 en 9.2 chimney flue fig. 1 - chimney flues legend fig. 1 page 7 1 chimney flue with insulated stainless-steel pipes 2 chimney flue on the existing chimney 3 inspection plug 4 inspection door 5 ≥ 3,5 mt • the chimney flue or chimney is of great importance for the correct running of t...

  • Page 8

    8 easy - sweet 3 en materials with thermal insulation and able to last against usual mechanical stresses. It must be insulated to avoid condensation and to reduce fume cooling effects. • the stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials. Chec...

  • Page 9

    9 easy - sweet 3 en fume exhaust is assured also in case of wind. • it should prevent the infiltration of rain, snow and animals. • the outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by obstacles laying nearby (see fig. 2 page 7). 9.7 chimney compon...

  • Page 10

    10 easy - sweet 3 en legend fig. 6 page 9 1 room to ventilate 2 external air inlet • the room must be endowed with an external air recycling for a good climate in your ambient. • the air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see fig. 6...

  • Page 11

    11 easy - sweet 3 en legend fig. 7 page 10 2 ≥ 0,3 mt 3-3 sectional view 4 shield grid 5 curve inlet to turn downwards • insert the n fitting on the i air intake pipe • connect n with q using a flexible or stiff tube with a diameter of 60 mm and a maximum length of 2 metres (see fig. 8 page 11). Fig...

  • Page 12

    12 easy - sweet 3 en and to avoid condensation in the pipes. • the fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm). • some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is sealed with the plug given with standard equipment...

  • Page 13

    13 easy - sweet 3 en fig. 13 - example 2 legend fig. 13 page 13 1 insulating material 2 inspection plug 3 chimney inspection entrance 4 minimum safety distance = 0,5 mt 5 inclination ≥ 3° 6 level section ≤ 1 mt • old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door...

  • Page 14

    14 easy - sweet 3 en we recommend to check with your chimney flue manufacturer the safety distances which must be respected and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (en 13501 - en 13063 - en 1856 - en 1806 - en 15827). 10 fuel 10.1 fuel...

  • Page 15

    15 easy - sweet 3 en 11.2 overall dimensions fig. 15 - general dimensions: easy legend fig. 15 page 15 1 44 cm 2 92 cm 3 49 cm 4 21 cm 5 19,3 cm 6 11,5 cm 7 16,5 cm 8 exhaust fumes d.8 cm 9 hole combustion air inlet d.6 cm fig. 16 - general dimensions: sweet 3 legend fig. 16 page 15 1 47 cm 2 94 cm.

  • Page 16

    16 easy - sweet 3 en legend fig. 16 page 15 3 48,5 cm 4 21 cm 5 21 cm 6 11,5 cm 7 18 cm 8 exhaust fumes d.8 cm 9 hole combustion air inlet d.6 cm 11.3 general installation fig. 17 - general installation legend 1 stove 2 minimum lateral distance = 300 mm 3 minimum rear distance = 200 mm 4 minimum fro...

  • Page 17

    17 easy - sweet 3 en 11.5 sweet side panel disassembly for this model there is no need to remove the frame to disassemble the side panels. To access the internal stove parts, disassemble the side panels as indicated below: • loosen the 3 back screws (see fig. 21 page 17). • turn the side panel outwa...

  • Page 18

    18 easy - sweet 3 en • the plug must be easily accessible when the appliance is installed. • please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not efficient, please endow you with one in compliance with the law. • connect the ...

  • Page 19

    19 easy - sweet 3 en • by using the stove the varnish inside the combustion chamber could be subjected to alterations. This occurrence can be attributed to different reasons: an excessive stove overheating, the presence of chemical agents in bad quality pellets, bad chimney draught, etc. Therefore v...

  • Page 20

    20 easy - sweet 3 en • finally press “menu” to confirm and “esc” to exit. Timer setting (see relative chapter) sleep setting (see relative chapter) 12.4 settings menu the settings menu allows to act on the boiler operating mode: a - language b - cleaning (displayed only when the boiler is switched o...

  • Page 21

    21 easy - sweet 3 en • scroll to “settings” using the arrows • press “menu” to confirm. • scroll to “off time eco” using the arrows. • press “menu” to confirm. • enter the minutes with the + - keys. • press “menu” to confirm and “esc” to exit. H - pellet recipe to change the recipe act as follows: •...

  • Page 22

    22 easy - sweet 3 en • if inside the combustion chamber there are booklets, manuals, etc..., remove them. • check if the door is correctly closed. • check if the stove is correctly inserted in the electric socket. • before switching the stove on, assure you the burning pot is clean. • to start the s...

  • Page 23

    23 easy - sweet 3 en fig. 32 - display note: the full stop to the right of the ambient temperature shown in the control panel display (upper right) indicates the half degree (e.G. 23.° means 23.5°c). Air fan speed - this function allows selecting the desired speed for the ambient fans from 1 to 5 or...

  • Page 24

    24 easy - sweet 3 en at this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu” key to confirm. The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the shutdown time, confirm with the “menu...

  • Page 25

    25 easy - sweet 3 en • after 5 minutes from the beginning of the switch-off procedure. 12.15 sleep function (main menu) the sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must switch off. To set the sleep function act as follows:...

  • Page 26

    26 easy - sweet 3 en fig. 40 - remove nut fig. 41 - digital pressure switch connection data p1 p2 p3 p4 p5 stove depression - temperature 6,5 kw 22,5/24,5 pa - 94°c 41,5/44,5 pa - 105°c 57,5/59,5 pa - 120°c 68/70 pa - 135°c 79/81 pa - 153°c nb: for good combustion, the depression values must be betw...

  • Page 27

    27 easy - sweet 3 en fig. 44 - door open fig. 45 - timer: 90 seconds to operate correctly, the stove must work with the pellet hopper door always closed; should it remain open for more than 90 seconds, the stove switches off. 12.22 remote control • the stove can be operated through a remote control....

  • Page 28

    28 easy - sweet 3 en - clogged exhaust - significant negative (wind) - clogged fume passages - open pellet loading tank - open fire door or worn/broken gaskets. 13.3 smoke temperature probe detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature d...

  • Page 29

    29 easy - sweet 3 en panel alert type of problem solution a02 the fire goes off abnormally. Check the level of pellets in the hopper. A03 thermostat alarms the temperature of the pellets hopper or the water temperature exceed the envisioned safety threshold. Wait for the cooling stage to end, cancel...

  • Page 30

    30 easy - sweet 3 en fig. 47 - burning pot extraction fig. 48 - ash tray extraction fig. 49 - burning pot cleaning • extract the burning pot (see fig. 47 page 30) from its seat and empty it from the ash. • extract the ash tray (see fig. 48 page 30) and empty it from the ash. • if necessary clean wit...

  • Page 31

    31 easy - sweet 3 en the hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom and the visible part of the auger exclusively as shown in the picture (see fig. 52 page 30). 14.4 fume chamber cleaning every 4/8 weeks the fume chamber cleaning must be executed. For the s...

  • Page 32

    32 easy - sweet 3 en fig. 57 - top deflector fig. 58 - right flue gas pass removal • remove the top deflector (see fig. 57 page 32). • remove the right deflector (see fig. 58 page 32). • clean with a pipe cleaner and suction any ash accumulated inside. • put everything back together. 14.6 fume condu...

  • Page 33

    33 easy - sweet 3 en fig. 60 - room fan cleaning • remove the sides. • remove dust build-up using a brush or a vacuum cleaner (see fig. 60 page 33). 14.8 fume pipes annual cleaning clean once a week from soot with brushes. The cleaning operation must be executed by a specialized stove-repairer who w...

  • Page 34

    34 easy - sweet 3 en 15 in case of anomaly 15.1 problem solving before of every authorized technician intervention, the same technician has the duty to check if the parameters of the mother board correspond to those of the table you own. In case of doubts regarding the use of the stove, please conta...

  • Page 35

    35 easy - sweet 3 en problem cause solution intervention the fire extinguish and the stove stops empty hopper full the hopper. Auger blocked by a foreign object (for example nails) clean the auger. Bad quality pellets try other types of pellets. Pellet drop value too low "phase 1" adjust the pellet ...

  • Page 36

    36 easy - sweet 3 en problem cause solution intervention the stove's smoke duct produces condensation low smoke temperature check that the flue is not clogged. Increase stove power to minimum (pellet drop and fan revs). Install condensation collection cup. 16 technical datas 16.1 repair information ...

  • Page 37

    37 easy - sweet 3 en 16.2 features description easy sweet 3 . Width 44 cm 47 cm depth 49 cm 48,5 cm height 92 cm 94 cm weight 62 kg 64 kg introduced thermic power (min/max) 2,6 - 7 kw 2,5 - 7 kw nominal thermic power (min/max) 2,4 - 6,5 kw 2,4 - 6,5 kw eficiency (min/max) 93 - 91,5 % 95 - 92 % fume ...