Regulator and Hose
Use only regulator and hose approved for LP Gas at the above pressures. The life expectancy of the
regulator is estimated as 10 years. It is recommended that the regulator is changed within 10 years of
the date of manufacture.
The use of wrong regulator or hose is unsafe; always check that you have the correct
items before operating the barbecue.
The hose used must conform to the relevant standard for the country of use. The length of the hose
must be 0.7 meters (minimum) and 1.5 meters (maximum). Worn or damaged hose must be replaced.
Ensure that the hose is not obstructed, kinked, or in contact with any part of the barbecue other than
at its connection. It is recommended that the hose is changed within 1 year of the date of
manufacture.
Storage of Appliance
Storage of an appliance indoors is only permissible if the cylinder is disconnected and removed from
the appliance. When the appliance is not to be used for a period of time it should be stored in its
original packaging and stored in a dry dust free environment.
Gas Cylinder
The gas cylinder should not be dropped or handled roughly! If the appliance is not in use, the cylinder must be
disconnected. Replace the protective cap on the cylinder after disconnecting the cylinder from the appliance.
Cylinders must be stored outdoors in an upright position and out of the reach of children. The
cylinder must never be stored where temperatures can reach over 50
°C. Do not store the cylinder
near flames, pilot lights or other sources of ignition. DO NOT SMOKE while using.
Connection to Appliance
Before connection, ensure that there is no debris caught in the head of the gas cylinder, regulator,
burner and burner parts.
Spiders and insects can nest within and clog the burner/venturi tube at the orifice. A clogged burner