Cadet EP101T Owner's Manual

Summary of EP101T

  • Page 1

    Cadetheat.Com tel: 855.Cadetus po box 1675 vancouver, wa 98668-1675 %hqh¿wv save these instructions energy plus heater owner’s guide f no no heat fan only sleep heat + 5 / 8 ” 1.6cm 9” 22.9cm side grill front wall can side wall can bottom 12” 30.5cm 10” 25.4cm 11 1 / 8 ” 28.3cm 3¼” 8.3cm 1¼” 3.2cm 1...

  • Page 2

    Save these instructions cadetheat.Com tel: 855.Cadetus po box 1675 vancouver, wa 98668-1675 important instructions wiring diagram thermostat control manual reset high temperature limit motor mode switch heating element black white white thermistor black red red yellow yellow black brown orange volta...

  • Page 3

    %hiruh\rxehjlq\rxvkrxognqrz f no no heat a a fan only sleep heat + f n o n o he a t aa f a n on l y sleep hea t + f no no heat a a fan only sleep heat + remove thermostat junction box cover (not included) to heater to breaker white wires black wires all ground wires derxwwkh&dghw(qhuj\3oxvkhdwhu vrp...

  • Page 4: __________________________

    Installation instructions strain relief connector knock-out (twist to remove) supply wire grounding screw ¾" (1.9cm) min. 1. :$51,1* verify that the electrical supply wires are the same voltage as the heater. ,iuhsodflqjdqh[lvwlqjkhdwhufkhfnwkhodeho of the old heater. $oohohfwulfdozrundqgpdwhuldovpx...

  • Page 5: __________________________

    Installation instructions (continued) __________________________ 3duw7zr __________________________ 9huli\6xsso\9rowdjh step 1 %hiruhlqvwdoolqjyhuli\srzhuvxsso\lvyrowv $txdol¿hgrughglfdwhgflufxlwiurppdlqglvfrqqhfwsdqholvuhtxluhg how do i insert the heater assembly into the wall can? ,qvwdoo+hdwhu$vv...

  • Page 6

    Operating instructions f no no heat a a no fan no heat fan only sleep heat + :$51,1* risk of electrical shock and fire. The heater must be properly installed before it is used. 1. Do not operate without grill. .Hhshohfwulfdofrugvgudshu\ixuqlvklqjvdqg rwkhufrpexvwleohvdwohdvwihhwpdzd\ iurpwkhiurqwriw...

  • Page 7

    Operating instructions (continued) resetting the manual reset limit control warranty fault codes digital display reads problem solution f no no heat model: v o lts: w a tts: w a r n in g ! T o a v o id e l e c t r ic a l s h o c k d is c o n n e c t p o w e r a t c irc u it b re a k e r b e fo re s ...

  • Page 8

    Troubleshooting chart symptom problem solution maintaining your heater &2168/7/2&$/(/(&75,&$/&2'(672'(7(50,1(:+$7:25.0867%(3(5)250('% (/(&75,&$/6(59,&(3(56211(/ +hdwhulvzrunlqj but room does not reach desired tem- perature. 1. Heat loss from room is greater than heater capacity.* 2. Furniture or oth...