4. Operating modes
The Mod. A 1733 – A 1833 and A 1733B – A 1833B boards can be controlled, either
locally or remotely, through the SY 1527 software interface. For details on SY 1527
system operation, please refer to the User's Manual of this product. The following
sections contain a description of commands available for the board control and status
monitoring.
ATTENTION
THE MOD. A1733, A1833, A1733B, A1833B BOARDS REQUIRE
SY 1527 FIRMWARE VERSION 1.09.04 OR LATER
4.1
Output control and monitoring
For each output channel, it is possible, through the SY 1527 system, to perform the
following operations:
• Assign to channel a symbolic name
• Set output voltage (VSET)
• Set max. output current (ISET)
• Set output voltage software limit (SVMAX)
• Set voltage ramp-up speed (RAMP-UP)
• Set voltage ramp-down speed (RAMP-DOWN)
• Set TRIP parameter
• Enable/disable POWER ON option
• Switch channel ON/OFF
• Monitor output voltage (VMON)
• Monitor output current (IMON)
• Monitor channel status
If the POWER ON option is enabled, the channel, at POWER ON, is restored in the
same condition it was before the POWER OFF or RESET; if this option is disabled, at
POWER ON or after a RESET, the channel is kept OFF independently from its previous
condition.
The following messages may be returned by the SY 1527 when monitoring the channel
status:
• OFF
(channel turned OFF)
• RUP
(channel ramping up)