Cal Amp Fusion Installation Manual - Installation Instructions
Installation Instructions
UL acceptance requires the following installation instructions. These installation instructions are
available and may be downloaded from the
www.calamp.com
website listed on the CalAmp Product
Information Card provided with each unit and include the following:
1.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous
locations only.
WARNING
– EXPLOSION HAZARD – Do not disconnect equipment unless power has been
removed or the area is known to be non-hazardous.
WARNING
— EXPLOSION HAZARD – Substitution of components may impair suitability for
Class I, Division 2.
2.
The unit is to be powered with a Listed Class 2 or LPS power supply rated at 9 to 28 VDC or
equivalent.
3.
Device must be installed in an end-use enclosure.
4.
All wiring routed outside the housing, except for the antenna, must be installed in grounded
conduit, following acceptable wiring methods based on installation location and electrical code.
5.
The USB and SIM connectors are for temporary connection only during maintenance and setup of
the device. Do not use, connect, or disconnect unless the area is known to be non-hazardous.
Connection or disconnection in an explosive atmosphere could result in an explosion.
6.
Do not operate reset switch unless area is known to be non-hazardous.
NON-INCENDIVE FIELD WIRING
Installation must be in accordance with the National Electric Code (NFPA 70, Article 504) and ANSI/ISA-
RF 12.6. (When the Fusion is located in a non-hazardous location, the maximum voltage is ±30 V and
maximum current is 1 A.)
APPROVED ACCESSORIES
The following table shows accessories that, when approved by the manufacturer, represent antennas
and cables used with modules in UL testing.