CALORIQUE THERMOLAR THS-106 Installation And Operation Manual - page 6
INST
ALLA
TION
THERMO-SENSORS
1.Using duct tape, attach the Over Limit thermo-sensor (marked with red) to the central area of
the upper-most heating element. Locate the sensor approximately 1-1/2 ft/450 mm from the
cord end of the heating element.
2.Using duct tape, attach the Maintenance thermo-sensor directly to the tank wall approximately
6 inches/150 mm from the bottom-most heating element.
CONTROL UNIT — ON TANK WALL
If the control unit is located on the tank itself, finish tightening the
strap so that the box is secured in place.
CONTROL UNIT — REMOTE LOCATION
If the control unit is located remotely from the tank, attach the con-
trol unit, using standard electrical practices, to any suitable surface,
pole, etc.
Note
Make sure that the strap does not cross any heating elements, power cords or thermo-
sensor leads.
Note
Standard lead lengths on the thermo-sensors and heating elements are 20 ft/6 m and
8 ft/2.5 m respectively. When locating the control unit, ensure that the thermo-sensor
wires and heating element power cords are not stretched taut and do not cross over
the heating elements.
4
Over Limit Sensor
Over Limit Sensor
Maintenance Sensor
Maintenance Sensor