OPERATING INSTRUCTIONS (cont.)
Red Glowing on Heating Element
The red glowing on the face of the heater (particularly noticeable in the dark) will
resemble charcoal glowing when hot. This is a normal phenomenon of catalization.
A properly operating heater will slightly “glow” on about 40% of the bottom area
of the heating element. At times, a high glow “spot” may be seen on the heating
element. This is normal. The glowing phenomenon diminishes over a period of years
usage.
CARE OF HEATER
General
• Anychangesoralterationstothisheateroritscontrols(or
attemptstocleanthecatalyticpad)canresultindamage,
compromisedoperation,decreasedperformanceand/or
riskofaccident.
• Alterationstotheheateroritscontrolcanresultinthe
heater’sfaultyoperation,whichmaycreatehazardous
conditions.
• Iftheinstructionsinthismanualarenotfollowedexactly,
afireorexplosionmanyresultcausingpropertydamage,
personalinjuryorlossoflife.
Cleaning
The heater and its surroundings should be kept clean and
free of dust.
• Itisrecommendedthattheheaterbekeptcoveredatall
timeswhennotinuse.Custom-madedustcoversare
availablefromthefactoryoryourlocaldealer(seechart
belowforpartnumber).DONOTCOVERHEATERWHILE
ITISHOT.
Wall Mounted
Portable
Wave3
57706
57722
Wave6
57713
57723
Wave8
57715
57724
• Theexterioroftheheatercanbecleanedwithadamp
cloth.Avoidthedirectuseofanyaerosolorspray-on
cleaners.Donotuseabrasivematerialorcleanersonthe
decalsorcontrolknob.Takecarenottogetmoisture,
cleanersorsolventsonthecatalyticelementsurface.
• Nevertouch,vacuumorwashoffthecatalystpad.This
maydestroytheactivecatalyticplatinumsurfaceand
makethepadinoperable.
Off Season
• Iftheheateristobeleft“OFF”foraconsiderableperiodof
time,thepropane(LP)gassupplytotheheatershouldbe
turnedoffasclosetothegassourceaspossible.
• Inthecaseofportableuse,thegasshouldbeturnedoff
atthepropane(LP)supplycylinder.
• Inthecaseofwall-mountedheaters,thereshouldbea
manualgasvalveinstalledneartheheater.
Service
Withgoodcareandnormaloperatingconditions,your
Olympian™CatalyticHeatershouldprovidemanyyearsof
warmthandcomfort.
The following service tips will assist you in taking
care of the heater.
• Locateandusetheheaterwhereitisleastlikelytobe
subjecttoimpact,exposuretoadverseweatherorin
directcontactwithcookingproductsorcleaningagents.
• Thegassupplysystemtotheheatershouldbechecked
periodicallybyaqualifiedLPGasservicetechnician.If
theheaterwillnotlight,willnotstaylit,ordoesnotput
outthenormalamountofheat,theveryfirstthingtodo
ischeckthegassupply.Findoutifthegasisavailable
attheheater.CheckLPGasregulatortoensurecorrect
manifoldpressure.
• Operationoftheheatershouldbecheckedbyaqualified
LPGasservicetechnicianwhentheheaterhasbeen
outofserviceforaconsiderableperiod(intermittent
operation)andinanyeventatleastonceayear.
• Forcontinuedhighefficiencyoperation,itis
recommendedthatthecatalystpadbereplacedevery
sevenyears,
and sooner if abnormal operation of the
pad is noticed
.Catalystpadreplacementmustbedoneat
thefactoryorbyacertifiedLPGastechnician.
• Theheaterhasnomovingpartsexceptinthegassupply
andcontrolsystem.Becauseofthis,partreplacementis
minimalandonlyafewpartscanbereplacedinthefield.
Thepartsdescribedhereincanbeeasilyreplacedinthe
field.
• Usersshouldnotattempttorepairorchangeanypartsof
theheater.Allrepairsmustbeperformedatthefactoryor
byaqualifiedLPGastechnician.
Piezo Electric Igniter
Ifnosparkisobtainedwhentheigniterbuttonispressed
severaltimes,thePiezoIgniter(Part#57800)orCeramicSpark
Plug(Part#57784)mayneedreplacement.Thesepartsare
availablethroughthefactory.