CAME AX3024U Installation Manual - page 8
Pa
g
.
8
- M
a
n
u
a
l co
d
e
:
1
1
9
D
V
3
2
11
9
D
V
3
2
ve
r.
1
.0
1.
0
0
8
/2
0
1
0 © C
A
M
E
c
a
n
c
e
ll
i a
u
to
m
a
ti
c
i s
.p.
a
. - T
h
e d
a
ta
a
n
d i
n
fo
rm
a
ti
o
n r
e
p
o
rt
e
d
i
n
t
h
is
i
n
st
a
ll
a
ti
o
n
m
a
n
u
a
l a
re s
u
sc
e
p
ti
b
le to
c
h
a
n
g
e
a
t a
n
y t
im
e
a
n
d w
it
h
o
u
t o
b
li
g
a
ti
o
n
o
n
C
A
M
E
c
a
n
c
e
ll
i a
u
to
m
a
ti
c
i s
.p.
a
. to n
o
ti
fy
u
se
rs
.
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and
compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed
by the installer.
Note: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in
the basis of the actual power draw by the connected devices and according to the local electrical code standards.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual
power draw and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said
products.
5.3 Cable list and minimum thickness
Connections
Type of cable
Type of cable
Length of cable
32 < 65 ft
Length of cable
32 < 65 ft
Control panel power supply 1200V
UL LISTED
CABLE/WIRE
3G x 14AWG
3G x 14AWG
3G x 14AWG
Motor power supply 24V
3 x 14AWG
3 x 14AWG
3 x 14AWG
Flashing light
2 x 20AWG
2 x 20AWG
2 x 20AWG
Photocell transmitters
2 x 20AWG
2 x 20AWG
2 x 20AWG
Photocell receivers
4 x 18AWG
4 x 18AWG
4 x 18AWG
Accessories power supply
2 x 20AWG
2 x 20AWG
2 x 20AWG
Control and safety devices
2 x 20AWG
2 x 20AWG
2 x 20AWG
Antenna
RG58
max. 32 ft
5.2 Tools and materials
5 Installation
Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against
mechanical damage.
• Fit tubing to drain away any water leaks which may cause oxidation
•
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with
extra insulation as compared to the other conductive parts inside
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and
non-moving parts.
• Make sure there is a mechanical stop for opening and closing.
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks