CAME FA4024CB Installation Manual - page 23
P
a
g
e
23 - M
a
n
u
a
l c
o
d
e: 1
1
9
D
W
0
1
E
N ve
rs
. 3 04/
2
0
1
3 © C
A
M
E
C
a
n
ce
lli A
u
to
m
a
ti
ci
S
.p.
A
. - T
h
e d
a
ta a
n
d i
n
fo
rm
ati
o
n p
rovi
d
e
d
i
n
t
h
is
m
a
n
u
a
l a
re s
u
b
je
ct to c
h
a
n
g
e
at a
n
y time wit
h
o
u
t p
ri
o
r n
o
ti
ce
b
y C
A
M
E
C
a
n
ce
lli A
u
to
m
a
ti
ci
S
.p.
A
.
F23
Opening delayed time0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 10 = 10 s
After an opening command, the M1 gearmotor starts with a delay. The delay time can be set between 1 s and 10 s.
F24
Closing delay time0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 25 = 25 s
After a closing command or after automatic closing, the M2 gearmotor starts with a delay. The delay time can be set between 1 s and 25 s.
F28 Manoeuvre
speed40 = Minimum speed (default) /… / 100 = Maximum speed
Setting the gearmotor speed during the manoeuvres.
F30
Slowdown speed 20 = Minimum speed (default) /... / 50 = Speed (default) /... / 60 = Maximum speed
Setting the gearmotor speed during slowdown.
F33 Calibration
speed30 = Minimum speed / … / 50 = Speed (default) / … / 60 = Maximum speed
Setting the speed of the run during calibration.
F34 Run
sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
Adjusting the sensitivity of obstacle detection during the run.
F35 Slowdown
sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
Adjusting the sensitivity of obstacle detection during slowdown.
F36
Partial opening adjustment 10 = 10% of the run (default) / … / 80 = 80% of the run
Adjustment in percentage of the total run, from leaf opening of the M2 gearmotor.
F37
Opening slowdown point 10 = 10% of the run / … / 25 = 25% of the run (default) / … / 60 = 60% of the run
Adjustment in percentage of the total run, from the starting point of slowdown during opening.
F38
Closing slowdown point 10 = 10% of the run / … / 25 = 25% of the run (default) / … / 60 = 60% of the run
Adjustment in percentage of the total run, from the starting point of slowdown during closing.
F39
Opening approach point1 = 1% of the run / … / 5 = 5% of the run (default) / … / 10 = 10% of the run
Adjustment in percentage of the total run, from the starting point of approach during opening.
F40
Closing approach point1 = 1% of the run / … / 5 = 5% of the run (default) / … / 10 = 10% of the run
Adjustment in percentage of the total run, from the starting point of approach during closing.
F46
Number of motors0 = M1 and M2 / 1 = M1 (default)
Setting the number of gearmotors connected to the control panel.
F50 Data
saving0 = Disabled (default) / 1 = Activated
Saving the users and memorised settings in the memory roll.
N.B. this function appears only if a memory roll has been inserted in the control board.
F51 Data
reading0 = Disabled (default) / 1 = Enabled
Loading the data saved into the memory roll.
N.B. this function appears only if a memory roll has been inserted in the control board.
F59
Enabling CAME logo0 = Disabled / 1 = Enabled (default) / 10 = 10 s / … / 180 = 180 s
The CAME can remain always on (default), always off , or can come on after the gate has closed for a time that can be set between 10 s and 180 s.
F60 Sleep
Mode
0 = Disabled (default) / 1 = Enabled
Enables a reduction in photocell energy consumption in standby.
U1
Adding a user1 = Step-by-step command (open-close) / 2 = Sequential command (open-stop-close-stop) / 3 = Open only command / 4 =
Pedestrian/partial command / 5 = B1-B2 contact output
Entry of up to 25 users and association of each with a function chosen from those available. Entry must be done with the transmitter or other command
device (see user paragraph with associated command).
U2
Deleting a user
Deleting a single user.
U3
Deleting a user0 = Disabled / 1 = Deleting all users
Deleting all users.
User menu