Installation
Before installing, do the following:
• Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off )
power supply;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage;
• Make sure that any connections inside the case (that provide continuance to the protective circuit) be fi tted with extra insulation
as compared to the other conductive parts inside;
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• Make sure there is a mechanical stop for opening and closing.
Installation must be carried out by expert qualifi ed personnel and in full compliance with current regulations.
Preliminary checks
Connection
Type of cable
Cable length 1 < 10 m
Cable length 10 < 20 m Cable length 20 < 30 m
230 V control panel power supply
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm
2
3G x 1.5 mm
2
3G x 2.5 mm
2
230 V motor power supply
3G x 1.5 mm
2
3G x 1.5 mm
2
3G x 2.5 mm
2
Flashing light
2 x 1.5 mm
2
2 x 1.5 mm
2
2 x 1.5 mm
2
Photocell transmitters
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers
4 x 1.5 mm
2
4 x 1.5 mm
2
4 x 1.5 mm
2
Accessories power supply
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 1 mm
2
Command and safety devices
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Antenna connection
RG58
max. 10 m
Encoder connection
TWISTED
max. 30 m
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power drawn by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not included in this manual, refer
only to the literature accompanying such products.
Make sure you have all the tools and materials you need for the installation at hand to work in total safety and compliance with the
current standards and regulations. The following fi gure illustrates an example of equipment needed by the installer.
Tools and materials
Cable list and minimum thickness