ENGLISH
J. End User guide
J-1 Maintenance of the automation
J-2 Normal operation
a) Control remote
Opening, closing and stop operations are done using only one key of the transmitter
b) Manual operation
In case of power outages, release the part, open and close the door manually
J-3 Troubleshooting
a) The V6000 operator is made to be environmentally friendly and requires little periodic maintenance.
b) The first time, check that the transmission system moves easily (release the device, push and pull the door manually).
c) After a period of operation, check that the door is balanced when it opens and closes, and that the springs are capable or raising
the door. Lubricate all mechanical parts regularly.
d) After a power outage, once power is restored, press the transmitter button once: the door will start moving again.
The door will stop if the
power supply is cut off .
Once power is restored,
press the transmitter
button, and the door will
open
Depending on the
programming, the door opens
until the set limit and then
stops
PROBLEM
POSSIBLE CAUSES
SOLUTION
The operator does not work
1. It is not plugged in properly
2. The fuse is burned
1. Call for assistance
2. Have fuse replaced by a technician
The door does not WORK
1. The transmitter hasn't been
memorised
2. The battery is fl at
1. Memorise the transmitter again
2. Replace the battery
The transmitter only works at close
range
The battery is fl at
Replace the battery
The chain moves, but the door does
not
The device is not locked
Lock the device
The alarm keeps sounding
1. The door has been open too long
2. Door-run counter
1. Close the door
2. Perform periodic maintenance
The door does not reach the
endpoints or does not work
Programming errors
Re-program the door run
The door does not work properly,
and the screen reads "H"
Micro-processor errors due to humidity 1. Call for assistance
Sudden stop or bounce while
working, and the screen reads "F"
1. The spring is unbalanced
2. Obstacle detected
3. The power source is unstable
1. Call for assistance
2. Adjust the power
3. Call for assistance
Squeaks when working
Need to apply lubricant between the
guides and the release mechanism
Lubricate
The chain is noisy
The chain is not tight enough
Tighten the chain, by turning the but on
the spring, and lubricate
N.B.: Warning: danger of electrocution. Call qualified, skilled technicians for any interventions for any powered parts.