CAME ZG5 Installation Manual - page 7
7
A
ll t
h
e d
at
a a
n
d i
n
fo
rm
at
io
n c
o
n
ta
in
ed h
er
ei
n
i
s c
o
n
si
d
er
ed
s
u
b
je
ct to c
h
an
g
e a
t a
n
y t
im
e a
n
d a
t o
u
r d
is
cr
et
io
n
ENGLISH
% % 43 0
&53)"),%M!
48
48
48 #
.#
$)2
Allows the control assembly to check the effi ciency of the safety de-
vices (photoelectric cells) after each opening or closing command.
A possible photoelectric cell malfunction is identifi ed with via LED
indicator fl ashing on the control panel, consequently cancelling any
remote control or pushbutton commands.
Electrical connection for safety test activation:
- photoelectric cell transmitters and receivers must be connected in
the following way (see scheme)
- turn dip-switch 8 to ON to carry out the test.
IMPORTANT:
when carrying out the safety test function, contacts N.C. if not used,
on the relative dip switches (see functions selection p. 8)
5.6 Photoelectric cells performance test
EB
EB
5.7 Gearmotor end-stop connection
Gearmotor end-stop assembly already connected for
installation on the left-hand side seen from inside.
FA
FC
NC
NC
COM
F
U W
M
V
FA
FC
NC
NC
COM
F
U W
M
V
For right-hand installation:
- reverse FA-FC of the end stops on the terminal board;
- reverse the U-V phases of the motor on the terminal board.
Output supplied for
electric lock (comes
on with the opening
command)
6
6
- VB1 (shifted) supplied for
electric lock a 12V
- VB2 (preset) supplied for electric
lock a 24V
5.8 Motor torque limiter
To alter the torque, move the fast-on (marked with black string) to one
of the 4 remaining positions: 1 min ÷ 4 max.