Camfil CITY M User Manual - page 3
Camfil – Clean Air Solutions 5
4 Camfil – Clean Air Solutions
3 VERSION HISTORY
Version Date
Signature Altered
001
See approval
Initial version
4 IDENTIFICATION PLATE
All Camfil City S and City M air purifiers have the identification plate at the power supply to the unit.
5 GUARANTEES AND UNDERTAKINGS
The guarantee relates to full functionality as per the details in this User Manual and covers errors
in software and hardware for a period of one year from the delivery date. Should the equipment
develop a fault, please contact your distributor.
Distributor:
Camfil Svenska AB
Industrigatan 3
SE-619 33 TROSA
Tel: +46 (0)156 537 00
Web: www.camfil.com
6 PREFACE
Thank you for buying a high quality air purifier from Camfil. We hope that you will be delighted with
the use of your Camfil air purifier.
IMPORTANT!
Before using your high quality air purifier, it is important that you, as the user:
1) read this User Manual
2) read the fan instructions
3) follow the safety instructions in both documents.
7 TECHNICAL SPECIFICATIONS
External dimensions, vertical model
City S
City M
Height (mm)
465
720
Width (mm)
340
340
Depth (mm)
345
345
Weight (kg)
12.0 (including new filters)
16.0 (including new filters)
Filter weight (kg)
2.0 kg (2 filters are needed)
4.3 kg (2 filters are needed)
8 FAN SPECIFICATIONS
Phase
1~
Nominal voltage
VAC
230
Nominal voltage range
VAC
200 .. 240
Frequency
Hz
50/60
Type of data definition
ml
Speed
min
~1
3200
Power input
W
83
Current draw
A
0.75
Min. ambient temperature
ºC
-25
Max. ambient temperature
ºC
+60
ml=max.load; subject to alterations
9 AIR FLOW
With filter H13 with odour, VOC & ozone removal
City S
City M
Step
Qv
[m
3
/h]
N
[rpm]
Pe
[W]
LpA
[dBA]
Qv
[m
3
/h]
N
[rpm]
Pe
[W]
LpA
[dBA]
1
21
561
5
20.7
37
520
4
15.5
2
47
865
6
28.3
67
728
5
15.5
3
82
1168
9
35.8
94
907
6
15.5
4
119
1428
12
40.2
127
1072
7
21.7
5
183
1866
22
44.9
251
1772
19
37.7
6 Max.
247
2267
36
51.9
433
2733
55
52.6
10 USE
The air purifier is used to clean indoor air by mechanically filtering, through highly efficient
filters. Development of the system is primary for expert users and installation companies for