Camille Bauer SIRAX MM1400 Operating Instructions Manual

Summary of SIRAX MM1400

  • Page 1

    Device handbook sirax mm1400 operating instructions sirax mm1400 camille bauer metrawatt ag aargauerstrasse 7 ch-5610 wohlen/switzerland tel: +41 56 618 21 11 fax: +41 56 618 21 21 info@cbmag.Com www.Camillebauer.Com.

  • Page 2

    Pm 1000269 000 02 device handbook sirax mm1400 2/60 legal information warning notices in this document warning notices are used, which you have to observe to ensure personal safety and to prevent damage to property. Depending on the degree of danger the following symbols are used: qualified personne...

  • Page 3

    Pm 1000269 000 02 device handbook sirax mm1400 3/60 table of contents 1. Introduction ………………………………………………………………………………………………… 5 1.1 purpose of this document ………………………………………………………………………………………… 5 1.2 scope of supply ………………………………………………………………………………………………… 5 1.3 further documents ……………………………………………………………………...

  • Page 4

    Pm 1000269 000 02 device handbook sirax mm1400 4/60 8. Touch screen calibration …………………………………………………………………………………………… 24 9. Phase rotation error screen ……………………………………………………………………………………… 25 10. Run hour ………………………………………………………………………………………………… 26 11. On hour ………………………………………………………………………………………………… 26 12. Nu...

  • Page 5

    Pm 1000269 000 02 device handbook sirax mm1400 5/60 1. Introduction 1.1 purpose of this document this document describes the universal measurement device sirax mm1400. It is intended to be used by: • installation personnel and commissioning engineers • service and maintenance personnel • planners sc...

  • Page 6

    Pm 1000269 000 02 device handbook sirax mm1400 6/60 3. Device overview 3.1 brief description the universal measuring device sirax mm1400 is suited for fixed mounting and the measurement of voltage, current, frequency, power, energy (active / reactive / apparent), power factor, phase angle, etc in lo...

  • Page 7

    Pm 1000269 000 02 device handbook sirax mm1400 7/60 4. Mechanical mounting the sirax mm1400 is designed for panel mounting. 4.1 panel cut out dimensional drawing mm1400: see section 16.1 4.2 mounting of the device the device is suitable for panel widths up to 5mm and a panel cutout of 96 x 96 mm. Va...

  • Page 8

    Pm 1000269 000 02 device handbook sirax mm1400 8/60 5. Electrical connections ensure under all circumstances that the leads are free of potential when connecting them! Please observe that the data on the type plate must be adhered to! The national provisions have to be observed in the installation a...

  • Page 9

    Pm 1000269 000 02 device handbook sirax mm1400 9/60 all voltage measurement inputs must originate at circuit breakers or fuses rated by 1 amps. This does not apply to the neutral connector. You have to provide a method for manually removing power from the device, such as a clearly labeled circuit br...

  • Page 10

    Pm 1000269 000 02 device handbook sirax mm1400 10/60 5.4 power supply a marked and easily accessible current limiting switch has to be arranged in the vicinity of the device for turning off the power supply. Fusing should be 10 amps or less and must be rated for the available voltage and fault curre...

  • Page 11

    Pm 1000269 000 02 device handbook sirax mm1400 11/60 6.1 operating the device 6.2 measurement reading screens 6.3 measurement parameter screen harmonic analyse: when this option is selected from power quality menu, meter shows the graphical analysis of the harmonics selected in setup --> power quali...

  • Page 12

    Pm 1000269 000 02 device handbook sirax mm1400 12/60 6.4 setup parameter screen password system parameters (sec. 7.2.1) system type (sec. 7.2.1.1) pt primary (sec. 7.2.1.2) pt secondary (sec. 7.2.1.3) ct primary (sec. 7.2.1.4) demand integration time (sec. 7.2.1.6) energy update rate (sec. 7.2.1.7) ...

  • Page 13

    Pm 1000269 000 02 device handbook sirax mm1400 13/60 7. Programming the following sections comprise step by step procedures for configuring the instrument for individual user requirements. To access the set-up screens touch on the “ setup ” icon in main menu. This will take the user into the passwor...

  • Page 14

    Pm 1000269 000 02 device handbook sirax mm1400 14/60 7.2. Menu selection after entering in the submenu 6 - setup, user will be asked to enter password & after input of correct password list of following parameters will be displayed on screen. 7.2.1 system parameters 7.2.5 power quality setup 7.2.2 c...

  • Page 15

    Pm 1000269 000 02 device handbook sirax mm1400 15/60 7.2.1.1. System type 7.2.1.2. Potential transformer primary value the nominal full scale voltage will be displayed as line to line voltages for all system types. 7.2.1.3 potential transformer secondary value this screen is used to set the system t...

  • Page 16

    Pm 1000269 000 02 device handbook sirax mm1400 16/60 in case presently displayed current transformer primary value together with the potential transformer primary value results in a maximum power of greater than 666.6 mva, “invalid value” will be display- ed. Example: if primary value of pt is set a...

  • Page 17

    Pm 1000269 000 02 device handbook sirax mm1400 17/60 this screen is used to set the period over which current and power readings are to be integrated. Four options: 8, 15, 20, 30 minutes are displayed on screen. Touching radio button in front of parti- cular option will select that option. Touch on ...

  • Page 18

    Pm 1000269 000 02 device handbook sirax mm1400 18/60 this screen applies to the rs 485 output only. This screen allows the user to set rs485 address parameter for the instrument. This screen can be accessed only from communication parameters list menu. Here again 0 to 9 digit input keypad is provide...

  • Page 19

    Pm 1000269 000 02 device handbook sirax mm1400 19/60 this screen allows the user to set baud rate of rs 485 port. Four options: 4800, 9600, 19200, 38400 bauds are displayed on screen. Touching radio button in front of particular option will select that option. Touch on “ ok key” will confirm the set...

  • Page 20

    Pm 1000269 000 02 device handbook sirax mm1400 20/60 touching on any parameter will display the confirmation dialog, now a touch on " yes key' will confirm the resetting of that particular parameter. Touching on " no key' will move back to reset parameters menu. For example resetting all energies wi...

  • Page 21

    Pm 1000269 000 02 device handbook sirax mm1400 21/60 select weekend by selecting the radio button (dark circle) in front of the day. These days will be considered as weekends for all seasons. Any day can be assigned as a holiday. Holidays can have separate profile structure than other type of days. ...

  • Page 22

    Pm 1000269 000 02 device handbook sirax mm1400 22/60 time zone window shows the seasons which are selected. In time zone user can assign a time zone period at which different tariff profile are applicable. User can assign different timezone, tariff profile rate for different day types in each season...

  • Page 23

    Pm 1000269 000 02 device handbook sirax mm1400 23/60 the brightness & contrast of the tft lcd screen can be varied by the user by sliding the sliders. Touching the “ ok key” will ok confirm the current brightness contrast setting. Touching the default key will set brightness and contrast as per fact...

  • Page 24

    Pm 1000269 000 02 device handbook sirax mm1400 24/60 this screen allows user to set the values of red, green and blue components of colors used to display the parameters of all three phases. Different colors can be assigned to each phase using combination of red, green and blue component values. L1,...

  • Page 25

    Pm 1000269 000 02 device handbook sirax mm1400 25/60 9. Phase rotation error screen vyb vry kvar sys v a kva min kw vbr angle max x1000 kvarh x1000 x1000 in ph r hz kvah ph y p.F. Kwh ph b kah %thd demand line-neutral voltage voltage main vl2 vl2 vl2 vl2 v vv v v 0.000 0.000 0.000 line-neutral volta...

  • Page 26

    Pm 1000269 000 02 device handbook sirax mm1400 26/60 vyb vry kvar sys v a kva min kw vbr angle max x1000 kvarh x1000 x1000 in ph r hz kvah ph y p.F. Kwh ph b kah %thd demand line-neutral voltage voltage main vl2 vl2 vl2 vl2 v vv v v 0.000 0.000 0.000 line-neutral voltage voltage main vl2 vl2 vl2 vl2...

  • Page 27

    Pm 1000269 000 02 device handbook sirax mm1400 27/60 inductive quadrant 3 -p -q quadrant 4 +p -q quadrant 1 +p +q quadrant 2 -p +q capacitive capacitive inductive 90 degrees (0.000) 0 degrees (+1.000) 180 degrees (-1.000) 270 degrees (0.000) 300 degrees (+0.500) 330 degrees (+0.866) 30 degrees (+0.8...

  • Page 28

    Pm 1000269 000 02 device handbook sirax mm1400 28/60 14. Service, maintenance and disposal for devices that have not been opened in the factory, no warranty or guarantee can be assumed. 14.1 repair work and modifications repair work and modifications shall exclusively be carried out by the manufactu...

  • Page 29

    Pm 1000269 000 02 device handbook sirax mm1400 29/60 auxiliary standard nominal auxillary a.C. Supply voltage tolerance d.C. Supply voltage tolerance a.C. Supply burden d.C. Supply burden operating measuring ranges voltage current power factor accuracy voltage / current frequency active / re-active ...

  • Page 30

    Pm 1000269 000 02 device handbook sirax mm1400 30/60 shock vibration temperature coefficient enclosure (ip for water & dust) standards emc emmision emc immunity safety protection class pollution degree installation category high voltage test modbus ( rs 485 ) option protocol baud rate parity modbus ...

  • Page 31

    Pm 1000269 000 02 device handbook sirax mm1400 31/60 15.2 connection and programming via rs485 (modbus rtu) interface follow the subsequent steps to program the transducer via the rs485 interface and modbus: step 1: connection connect the modbus cable according to the connection diagram in chapter 5...

  • Page 32

    Pm 1000269 000 02 device handbook sirax mm1400 32/60 the each byte in rtu mode has following format: 8-bit binary, hexadecimal 0-9, a-f 2 hexadecimal characters contained in each 8-bit field of the message format of data bytes 4 bytes (32 bits) per parameter. Floating point format ( to ieee 754) mos...

  • Page 33

    Pm 1000269 000 02 device handbook sirax mm1400 33/60 response: volt3 (219.25v) 01 (hex) 04 (hex) 04 (hex) 43 (hex) 5b (hex) 41 (hex) 21 (hex) 6f (hex) 9b (hex) device address function code byte count data register1 high byte data register1 low byte data register2 high byte data register2 low byte cr...

  • Page 34

    Pm 1000269 000 02 device handbook sirax mm1400 34/60 30073 37 wh import / utility 00 48 • • 30075 38 wh export / gen 00 4a • • 30077 39 capacitive / utility varh 00 4c • • 30079 40 inductive / gen varh 00 4e • • 30081 41 vah / vah utility 00 50 • • 30083 42 - - - - - 30085 43 w demand (import) 00 54...

  • Page 35

    Pm 1000269 000 02 device handbook sirax mm1400 35/60 30187 94 running zone active export cost 00 ba • • 30189 95 running zone reactive import energy 00 bc • • 30191 96 running zone reactive import cost 00 be • • 30193 97 running zone reactive export energy 00 c0 • • 30195 98 running zone reactive ex...

  • Page 36

    Pm 1000269 000 02 device handbook sirax mm1400 36/60 30285 143 watt harmonic c l1 01 1c • x 30287 144 var harmonic c l1 01 1e • x 30289 145 va harmonic c l1 01 20 • x 30291 146 pf harmonic c l1 01 22 • x 30293 147 voltage hd harmonic c l1 01 24 • • 30295 148 current hd harmonic c l1 01 26 • • 30297 ...

  • Page 37

    Pm 1000269 000 02 device handbook sirax mm1400 37/60 30381 191 watt harmonic b l2 01 7c • x 30383 192 var harmonic b l2 01 7e • x 30385 193 va harmonic b l2 01 80 • x 30387 194 pf harmonic b l2 01 82 • x 30389 195 voltage hd harmonic b l2 01 84 • • 30391 196 current hd harmonic b l2 01 86 • x 30393 ...

  • Page 38

    Pm 1000269 000 02 device handbook sirax mm1400 38/60 30479 240 var harmonic a l3 01 de • x 30481 241 va harmonic a l3 01 e0 • x 30483 242 pf harmonic a l3 01 e2 • x 30485 243 voltage hd harmonic a l3 01 e4 • • 30487 244 current hd harmonic a l3 01 e6 • • 30489 245 vrms harmonic b l3 01 e8 • • 30491 ...

  • Page 39

    Pm 1000269 000 02 device handbook sirax mm1400 39/60 16.2 accessing sag, swell, over current data through modbus the sag, swell, over current time stamping data can be accessed from the addresses shown in table 2. In this case hour & minute parameters are combined on one location and date, month & y...

  • Page 40

    Pm 1000269 000 02 device handbook sirax mm1400 40/60 30653 327 sag19 minute /sag19 hour 02 8c 30655 328 sag19 date/ sag19 month/ sag19 year 02 8e 30657 329 sag20 minute /sag20 hour 02 90 30659 330 sag20 date/ sag20 month/ sag20 year 02 92 30661 331 sag21 minute /sag21 hour 02 94 30663 332 sag21 date...

  • Page 41

    Pm 1000269 000 02 device handbook sirax mm1400 41/60 30751 376 swell13 date/ swell13 month/ swell13 year 02 ee 30753 377 swell14 minute /swell14 hour 02 f0 30755 378 swell14 date/ swell14 month/ swell14 year 02 f2 30757 379 swell15 minute /swell15 hour 02 f4 30759 380 swell15 date/ swell15 month/ sw...

  • Page 42

    Pm 1000269 000 02 device handbook sirax mm1400 42/60 30849 425 over current8 minute /over current8 hour 03 50 30851 426 over current8 date/ over current8 month/ over current8 year 03 52 30853 427 over current9 minute /over current9 hour 03 54 30855 428 over current9 date/ over current9 month/ over c...

  • Page 43

    Pm 1000269 000 02 device handbook sirax mm1400 43/60 16.3 accessing 3 x for reading time of day data time of day data can be read from 3 x register only after setting the 4 x register address 40083 (parameter no. 41 in 4 x register). For different values in 40083 different tod data can be read. Sett...

  • Page 44

    Pm 1000269 000 02 device handbook sirax mm1400 44/60 30029 14 current date timezone2 kvarh import energy 00 1c 30031 15 current date timezone3 kvarh import energy 00 1e 30033 16 current date timezone4 kvarh import energy 00 20 30035 17 current date timezone5 kvarh import energy 00 22 30037 18 curren...

  • Page 45

    Pm 1000269 000 02 device handbook sirax mm1400 45/60 30419 209 month 12 kwh export energy 01 a2 30421 210 month 1 kvarh import energy 01 a4 30423 211 month 2 kvarh import energy 01 a6 30441 220 month 11 kvarh import energy 01 b8 30443 221 month 12 kvarh import energy 01 ba 30445 222 month 1 kvarh ex...

  • Page 46

    Pm 1000269 000 02 device handbook sirax mm1400 46/60 30899 449 month 1 kvah cost 03 82 30901 450 month 1 kvah cost 03 84 30919 459 month 11 kvah cost 03 96 30921 460 month 12 kvah cost 03 98 30923 461 current date timezone1 kwh import cost 03 9a 30925 462 current date timezone2 kwh import cost 03 pc...

  • Page 47

    Pm 1000269 000 02 device handbook sirax mm1400 47/60 30011 6 timezone6 date 1 energy 00 a 30013 7 timezone1 date 1 cost 00 c 30015 8 timezone2 date 1 cost 00 e 30017 9 timezone3 date 1 cost 00 10 30019 10 timezone4 date 1 cost 00 12 30021 11 timezone5 date 1 cost 00 14 30023 12 timezone6 date 1 cost...

  • Page 48

    Pm 1000269 000 02 device handbook sirax mm1400 48/60 16.5 accessing 4 x register for reading & writing: each setting is held in the 4x registers. Modbus code 03 is used to read the current setting and code 16 is used to write/change the setting. Refer table 6 for 4x register addresses. Example: read...

  • Page 49

    Pm 1000269 000 02 device handbook sirax mm1400 49/60 table 6: 4 x register addresses adress (register) parameter no. Parameter read / write modbus start adress hex high byte low byte 40003 1 demand period r/wp 00 02 40005 2 energy resolution r/wp 00 04 40007 3 system voltage r 00 06 40009 4 system c...

  • Page 50

    Pm 1000269 000 02 device handbook sirax mm1400 50/60 40147 73 over current threshold r/wp 00 92 40149 74 phase no for harmonic setup r/wp 00 94 40151 75 harmonic a r/wp 00 96 40153 76 harmonic b r/wp 00 98 40155 77 harmonic c r/wp 00 9a 40157 78 harmonic d r/wp 00 9c 40159 79 harmonic e r/wp 00 9e 4...

  • Page 51

    Pm 1000269 000 02 device handbook sirax mm1400 51/60 40019 rs485 set-up code this address is used to set the baud rate, parity, number of stop bits. Refer to table 7 for details. 40021 node address this register address is used to set device address between 1 to 247 . 40033 pt primary this address a...

  • Page 52

    Pm 1000269 000 02 device handbook sirax mm1400 52/60 40109 holiday date this address allows to read or write the value of date of holiday no specified in address 40107. 40111 holiday month this address allows to read or write the value of month of holiday no specified in address 40107. 40113 alterna...

  • Page 53

    Pm 1000269 000 02 device handbook sirax mm1400 53/60 40167 rtc date this address allows to read or write the value of date of rtc. 40169 rtc month this address allow to read or write the value of month of rtc. 40171 rtc year this address allows to read or write the value of year of rtc. 40173 bright...

  • Page 54

    Pm 1000269 000 02 device handbook sirax mm1400 54/60 16.6 user assignable modbus register the multifunction energy meter contains 20 user assignable registers in the address range of 0x2200 (38705) to 0x2226 (38743) (see table 8). Any of the parameter addresses (3x register addresses table 1) access...

  • Page 55

    Pm 1000269 000 02 device handbook sirax mm1400 55/60 table 9: user assignable mapping register (4x register) adress (register) parameter number assignable register modbus start adress hex high byte low byte 48705 4353 mapped add for register #0x2200 22 00 48706 4354 mapped add for register #0x2202 2...

  • Page 56

    Pm 1000269 000 02 device handbook sirax mm1400 56/60 start address high: most significant 8 bits of starting address of user assignable register. Start address low: least significant 8 bits of starting address of user assignable register. Number of register hi: most significant 8 bits of number of r...