9. Adjusting the Reference Positions
If the reference positions are not properly adjusted for all hands, the watch improperly
operates.
When the reference positions are found improper, perform the following procedure to
adjust the reference position of each hand. (This procedure must also be completed after
battery replacement.)
1)
Pull the crown out to the second
click position.
2)
Simultaneously press three
buttons that are designated (A),
(B), and (C). This causes the
year, month, date, and day-of-
the-week hands to sequentially
start moving.
Year
(C)
(B)
Crown
(A)
Date
Month
Day of the week