Campbell 05103 Instruction Manual - 5. Maintenance and Repairs
05103, 05106, and 05305 R.M. Young Wind Monitors
4
21Xs without OSX PROMS and CR7s without OS7 PROMS
(dataloggers purchased prior to March 1989 and August 1991
respectively, and not updated) do not have the option of
outputting frequency in hertz. Program Instruction 3 with
configuration code 11 (pulses per execution interval). The
multiplier from Table 4-1 is divided by the execution interval in
seconds to obtain the multiplier used with code 11. For example,
with a 10-second execution interval, the multiplier for
meters/second with the 05103 would be 0.0980/10 = 0.0098.
The offset remains zero.
4.2 Wind Direction Instruction Code
The wind direction sensor is a potentiometer that is measured as a “half
bridge”. The output ranges from 0 mV at 0 degrees to the excitation voltage at
355 degrees. In dataloggers programmed with Edlog, measure the wind
direction with Instruction 4 (Excite, Delay, and Measure). CR200 series
dataloggers use the ExDelSE instruction and other CRBasic dataloggers use the
BRHalf instruction. In general, a delay of 1 (0.01 seconds) is sufficient when
lead lengths are less than 100 feet. If the cable is 100 to 1000 feet, use a delay
of 5 (0.05 seconds). The wind direction potentiometer has a five degree
deadband between 355 and 360 degrees; therefore, the maximum signal is at
355 degrees. The result of the BRHalf instruction prior to applying the
multiplier is measured mV/Excitation mV; therefore, the multiplier is 355. The
other measurement result is the measured mV; the multiplier with these
instructions is 355/Excitation Voltage. The offset is zero. The parameters to
be used with each datalogger are listed in Table 4-2.
TABLE 4-2. Instruction 4 Parameters for Wind Direction
CR10(X)
21X
CR7
Measurement Range
2500 mV, slow
5000 mV, slow
5000 mV, fast
Excitation Voltage
2500 mV
5000 mV
5000 mV
Multiplier
0.142 deg/mV
0.071 deg/mV
0.071 deg/mV
Offset
0
0
0
5. Maintenance and Repairs
R.M. Young suggests the anemometer bearings be inspected at least every 24
months. Please refer to the R.M. Young manual for maintenance information.
Contact R.M. Young's customer service department directly to obtain repair
cost estimates and authorization for return of the unit. Their phone number is
(616) 946-3980.