Campbell 10164-L Instruction manual

Manual is about: Sampler Control Cable for use with Isco and Sigma Autosamplers

Summary of 10164-L

  • Page 1

    10164-l sampler control cable for use with isco and sigma autosamplers revision: 9/12 c o p y r i g h t © 1 9 9 8 - 2 0 1 2 c a m p b e l l s c i e n t i f i c , i n c ..

  • Page 3: Warranty

    Warranty “products manufactured by campbell scientific, inc. Are warranted by campbell scientific, inc. (“campbell”) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified in the corresponding campbell...

  • Page 4: Assistance

    Assistance products may not be returned without prior authorization. The following contact information is for us and international customers residing in countries served by campbell scientific, inc. Directly. Affiliate companies handle repairs for customers within their territories. Please visit www...

  • Page 5: Table of Contents

    Table of contents pdf viewers: these page numbers refer to the printed version of this document. Use the pdf reader bookmarks tab for links to specific sections. 1. General ........................................................................1 2. Specifications ......................................

  • Page 6

    Table of contents ii.

  • Page 7: 1.  General

    10164-l sampler control cable for use with isco and sigma autosamplers 1. General the 10164-l sampler control cable enables a datalogger to trigger an isco, american sigma, or connector-compatible autosampler. Through this cable, the datalogger can inhibit the sampler from running its programmed sam...

  • Page 8: 3.  Wiring

    10164-l sampler control cable for use with isco and sigma autosamplers 3. Wiring 3.1 general wiring information figure 3-1 shows a schematic of the 10164 and table 3-1 shows pin connector and wire functions. Sections 3.2 through 3.4 provide information about connecting the wires to a datalogger. The...

  • Page 9

    10164-l sampler control cable for use with isco and sigma autosamplers 3.2 triggering sampler table 3-2 shows the datalogger connections required to trigger the sampler. Table 3-2. Datalogger wiring for triggering sampler color description cr800 cr850 cr1000 cr3000 cr500 cr510 cr10(x) cr23x 21x purp...

  • Page 10: 4.  Programming

    10164-l sampler control cable for use with isco and sigma autosamplers table 3-4. Datalogger wiring to inhibit a sigma sampler program color description cr800 cr850 cr1000 cr3000 cr500 cr510 cr10(x) cr23x 21x purple ground g g brown control port control port (c1, c2,…) control port (c1, c2,…) contro...

  • Page 11

    10164-l sampler control cable for use with isco and sigma autosamplers 4.1 crbasic programming 4.1.1 trigger sampler to trigger the sampler, the datalogger program must set the port high, delay for at least 0.5 seconds, and then set the port low. Table 4-1. Wiring for crbasic triggering sampler exam...

  • Page 12

    10164-l sampler control cable for use with isco and sigma autosamplers 'cr1000 series datalogger 'declare public variables public events 'define data tables datatable (sampler,1,1000) totalize (1,events,fp2,false) endtable 'main program beginprog scan (1,sec,0,0) pulsecount (events,1,1,0,0,1.0,0) 'c...

  • Page 13

    10164-l sampler control cable for use with isco and sigma autosamplers table 4-4. Wiring for example of inhibiting a sigma sampler onboard program color description cr800, cr850, cr1000, orcr3000 purple ground g brown control port c1 clear shield g for samplers such as the products manufactured by s...

  • Page 14

    10164-l sampler control cable for use with isco and sigma autosamplers do (p86) 1: 52 set port 2 low you can also supply the trigger signal from switched excitation if no control ports are available. In this case, connect the yellow cable to the desired excitation channel (say e3) and pulse the chan...

  • Page 15

    10164-l sampler control cable for use with isco and sigma autosamplers cr10(x) program (subroutine 98 in program table 3) * 3 table 3 subroutines 1: beginning of subroutine (p85) 1: 98 subroutine number 2: z=z+1 (p32) 1: 10 z loc [ sample_no ] 3: do (p86) 1: 10 set high flag 0 (output flag) 4: set a...

  • Page 16

    10164-l sampler control cable for use with isco and sigma autosamplers 10

  • Page 18

    Campbell scientific companies campbell scientific, inc. (csi) 815 west 1800 north logan, utah 84321 united states www.Campbellsci.Com • info@campbellsci.Com campbell scientific africa pty. Ltd. (csaf) po box 2450 somerset west 7129 south africa www.Csafrica.Co.Za • cleroux@csafrica.Co.Za campbell sc...