Campbell CS210 Instruction Manual

Manual is about: relative humidity sensor

Summary of CS210

  • Page 1

    Cs210 enclosure relative humidity sensor revision: 10/07 c o p y r i g h t © 1 9 9 6 - 2 0 0 7 c a m p b e l l s c i e n t i f i c , i n c ..

  • Page 2: Warranty and Assistance

    Warranty and assistance the cs210 enclosure relative humidity sensor is warranted by campbell scientific, inc. To be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. Campbe...

  • Page 3: Cs210 Table of Contents

    Cs210 table of contents pdf viewers note: these page numbers refer to the printed version of this document. Use the adobe acrobat® bookmarks tab for links to specific sections. 1. General .........................................................................1 2. Specifications ......................

  • Page 4

    This is a blank page..

  • Page 5: 1.  General

    Cs210 enclosure humidity sensor 1. General the cs210 enclosure humidity sensor contains an elan hm2000 series precision bulk-polymer relative humidity sensor. It is used to monitor the relative humidity inside an equipment enclosure deployed in the field. The cs210 was once known as the 10162. Note ...

  • Page 6: 4.  Wiring

    Cs210 enclosure humidity sensor figure 1. Cs210 installed on a cr1000 4. Wiring connections to campbell scientific dataloggers are given in table 1 and figure 2. The probe is measured by a single-ended analog input channel. Table 1. Datalogger connections description color cr200-series cr800, cr850,...

  • Page 7: 5.  Programming

    Cs210 enclosure humidity sensor 5. Programming this section is for users who write their own datalogger programs. A datalogger program to measure this sensor can be created using campbell scientific’s short cut program builder software. You do not need to read this section to use short cut. The rela...

  • Page 8

    Cs210 enclosure humidity sensor 'define data tables datatable (daily,1,-1) datainterval (0,1,day,10) minimum (1,batt_volt,fp2,0,false) minimum (1,paneltempc,fp2,false,false) maximum (1,paneltempc,fp2,false,false) maximum (1,enc_rh,fp2,false,false) endtable 'main program beginprog scan (10,sec,0,0) p...

  • Page 9

    Cs210 enclosure humidity sensor 'main program beginprog scan (10,sec) battery (batt_volt) 'power the cs210 using c2 and leave it on. Portset (c2,1 ) voltse (enc_rh,1,1,0.1,0) 'set the sensor to 100% if it exceeds 100%. If enc_rh > 100 then enc_rh = 100 calltable daily nextscan endprog 5.2 edlog exam...

  • Page 10

    Cs210 enclosure humidity sensor example 4. Sample 21x program ;{21x} ; *table 1 program 01: 10 execution interval (seconds) 1: batt voltage (p10) 1: 1 loc [ batt_volt ] 2: panel temperature (p17) 1: 2 loc [ pnltempc ] ;turn the cs210 on and leave it on. ;the cs210 needs approximately 10 seconds to s...

  • Page 11: 6.  Enclosure Humidity

    Cs210 enclosure humidity sensor 11: maximum (p73) 1: 1 reps 2: 0 value only 3: 3 loc [ enc_rh ] *table 2 program 02: 0.0000 execution interval (seconds) *table 3 subroutines end program 6. Enclosure humidity change the enclosure desiccant packs (model number 4905) when the enclosure relative humidit...

  • Page 12

    Cs210 enclosure humidity sensor this is a blank page. 8.

  • Page 13

    This is a blank page..

  • Page 14

    Campbell scientific companies campbell scientific, inc. (csi) 815 west 1800 north logan, utah 84321 united states www.Campbellsci.Com info@campbellsci.Com campbell scientific africa pty. Ltd. (csaf) po box 2450 somerset west 7129 south africa www.Csafrica.Co.Za cleroux@csafrica.Co.Za campbell scient...