Campbell CS500 Instruction Manual - 6.  Long Lead Lengths

Manual is about: Temperature and relative humidity probe

Summary of CS500

  • Page 1

    Instruction manual cs500 temperature and relative humidity probe revision: 7/04 c o p y r i g h t ( c ) 1 9 9 5 - 2 0 0 4 c a m p b e l l s c i e n t i f i c , i n c ..

  • Page 2: Warranty and Assistance

    Warranty and assistance the cs500 temperature and relative humidity probe is warranted by campbell scientific, inc. To be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. C...

  • Page 3: Cs500 Table of Contents

    I cs500 table of contents pdf viewers note: these page numbers refer to the printed version of this document. Use the adobe acrobat® bookmarks tab for links to specific sections. 1. General ........................................................................1 2. Specifications .....................

  • Page 4

    This is a blank page..

  • Page 5: Humidity Probe

    1 cs500 temperature and relative humidity probe 1. General the cs500 temperature and relative humidity probe contains a platinum resistance temperature detector (prt) and a vaisala intercap® capacitive relative humidity sensor. The -l option on the model cs500 temperature and relative humidity probe...

  • Page 6: 3.  Installation

    Cs500 temperature and relative humidity probe 2 temperature accuracy: 0 0.4 0.8 1.2 1.6 -0.4 -0.8 -1.2 -1.6 -20 -40 0 temperature ( c) o ( c) error o 20 40 60 2.2 relative humidity sensor sensor: intercap ® relative humidity measurement range: 0 to 100% non-condensing rh output signal range: 0 to 1....

  • Page 7

    Cs500 temperature and relative humidity probe 3 the cs500 is held in place, within the 41003 or ut12va radiation shield, via an adapter, model 41381. The 41381 adapter is threaded onto the bottom of the cs500 (figure 4). The 41004 12-plate radiation shield, used with 207 probes, can be converted to ...

  • Page 8

    Cs500 temperature and relative humidity probe 4 figure 2. Cs500 and 41303 radiation shield figure 3. Cs500 and 41003 radiation shield on a cm6/cm10 tripod mast mounting clamp.

  • Page 9

    Cs500 temperature and relative humidity probe 5 figure 4. Radiation shield, cs500, and 41381 adapter figure 5. Cs500 wiring 41003 10-plate radiation shield lock nut tightens against adapter cs500 41381 adapter black temperature signal brown relative humidity signal green signal & power reference red...

  • Page 10: 4.  Wiring

    Cs500 temperature and relative humidity probe 6 table 1. Datalogger connections description color cr23x/cr1000 cr10(x), cr510 21x, cr7 temperature black single-ended input single-ended input single-ended input relative humidity brown single-ended input single-ended input single-ended input signal & ...

  • Page 11

    Cs500 temperature and relative humidity probe 7 table 4. Wiring for cr1000 and cr10x examples description color cr1000 cr10(x) temperature black se 1 se 3 (2h) relative humidity brown se 2 se 4 (2l) signal & power reference green g g power red 12 v 12 v shield clear g 5.1 example for cr1000 'cr1000 ...

  • Page 12: 6.  Long Lead Lengths

    Cs500 temperature and relative humidity probe 8 ;measure the cs500 relative humidity. ; 02: volt (se) (p1) 1: 1 reps 2: 5 2500 mv slow range ;cr500 (2500 mv); cr23x (1000 mv); 21x, cr7 (5000 mv) 3: 4 se channel ;brown wire (se 4), green wire (g) 4: 3 loc [ rh_pct ] 5: .1 mult ;see table 3 for altern...

  • Page 13: 7.  Absolute Humidity

    Cs500 temperature and relative humidity probe 9 this voltage drop will raise the apparent temperature and relative humidity because the difference between the signal and signal reference, at the datalogger, has increased by v d . The approximate error in temperature and relative humidity is 0.35 °c ...

  • Page 14

    Cs500 temperature and relative humidity probe 10 example 1. Sample cr10(x) program that computes vapor pressure and saturation vapor pressure ;measure the cs500 temperature. ; 01: volt (se) (p1) 1: 1 reps 2: 5 2500 mv slow range ;cr500 (2500 mv); cr23x (1000 mv); 21x, cr7 (5000 mv) 3: 3 se channel ;...

  • Page 15: 8.  Maintenance

    Cs500 temperature and relative humidity probe 11 ;compute the vapor pressure in kpa. ;relative humidity must be a fraction. ; 07: z=x*y (p36) 1: 3 x loc [ e_sat ] 2: 2 y loc [ rh_frac ] 3: 4 z loc [ e ] 8. Maintenance the cs500 probe requires minimal maintenance. Check monthly to make sure the radia...

  • Page 16

    Cs500 temperature and relative humidity probe 12 this is a blank page..

  • Page 17

    This is a blank page..

  • Page 18

    Campbell scientific companies campbell scientific, inc. (csi) 815 west 1800 north logan, utah 84321 united states www.Campbellsci.Com info@campbellsci.Com campbell scientific africa pty. Ltd. (csaf) po box 2450 somerset west 7129 south africa www.Csafrica.Co.Za sales@csafrica.Co.Za campbell scientif...