Campbell DSP4 Instruction Manual - Warranty and Assistance

Summary of DSP4

  • Page 1

    Instruction manual dsp4 heads up display revision: 2/99 c o p y r i g h t ( c ) 1 9 8 4 - 1 9 9 9 c a m p b e l l s c i e n t i f i c , i n c ..

  • Page 2: Warranty and Assistance

    Warranty and assistance the dsp4 heads-up display is warranted by campbell scientific, inc. To be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. Campbell scientific, inc....

  • Page 3

    Dsp4 heads up display table of contents pdf viewers note: these page numbers refer to the printed version of this document. Use the adobe acrobat® bookmarks tab for links to specific sections. Page warranty and assistance 1. Introduction 1.1 specifications ..............................................

  • Page 4

    This is a blank page..

  • Page 5

    1 dsp4 heads up display 1. Introduction 1.1 specifications power requirement: 10.0 to 15.6 vdc at 1 amp operating range: -40 to +80°c standard dimensions: 2.9" x 12.9" x 3.3" 1.2 product terminology 1. Power on/off switch 2. 12 volt dc power plug 3. 9-pin female ribbon connector 4. 9 pin male ribbon...

  • Page 6

    Dsp4 heads up display 2 2. Preparation 2.1 installation when installing the dsp4, use the 1/4x20x1/3" mounting bracket screw holes on both side panels (figure 1.2.1 item 11). Velcro is also used in many applications to mount and secure the unit. In direct sunlight, a sun shield or visor may be used ...

  • Page 7

    Dsp4 heads up display 3 momentarily pressing the up or down key causes a single location change. Note: if either key is pushed for longer than 1/3 of a second, the locations scroll at a rapid rate. With the cursor under the colon in the first quadrant, pressing the up or down keys causes all four di...

  • Page 8

    Dsp4 heads up display 4 minutes.) after completing the programming, press the dsp4 select key to call the datalogger and restore the command menu. 3.4.2 from a storage module or csm1 (load mode) to program the datalogger from an sm192/ sm716/ csm1 storage module, connect the storage module to the 9 ...

  • Page 9

    Dsp4 heads up display 5 becomes transparent; the remote operator sees only the datalogger responses. The dsp4 does however, show all the telecommunications on the display. When the remote operator issues the "e" command or allows the link to time out, the dsp4 automatically re-establishes communicat...

  • Page 10

    Dsp4 heads up display 6 3.10 dsp4 reset and memory backup 3.10.1 backup from operating datalogger the dsp4 retains its datalogger program and associated labels even if the dsp4 power is removed as long as the dsp4 is connected to an operating datalogger. The backup power for the dsp4 memory is suppl...

  • Page 11

    A-1 appendix a. Changing prom or ram chips the dsp4 has 5 sockets for memory chips. Two sockets hold 8 k random access memory (ram) chips and two hold programmable read only memory (prom) chips. There is one empty socket between the two types of memory. A.1 disassembly of the dsp4 1. Turn power off,...

  • Page 13

    This is a blank page..

  • Page 14

    Campbell scientific companies campbell scientific, inc. (csi) 815 west 1800 north logan, utah 84321 united states www.Campbellsci.Com info@campbellsci.Com campbell scientific africa pty. Ltd. (csaf) po box 2450 somerset west 7129 south africa www.Csafrica.Co.Za sales@csafrica.Co.Za campbell scientif...